Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- SIGMACOVER 350 BASE ALUMINIUM
- Product Form
- Liquid
- Product Code
- 000001090721
- Synonyms
- 00347321; 00350667
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Professional applications, Used by spraying. Coating.
Uses advised against
Not applicable.
Manufacturers & Suppliers
PPG Architectural Coatings Canada, Inc.
manufacturer
1550, rue Ampère, bureau 500, Boucherville (Québec) J4B 7L4, Canada
+1 450-655-3121
PPG Industries, Inc.
manufacturer
One PPG Place, Pittsburgh, PA 15272
888-977-4762
Emergency Contacts
Emergency Contact
(412) 434-4515
Emergency Contact
(514) 645-1320
SETIQ Interior de la República
800-00-214-00
SETIQ Ciudad de México
(55) 5559-1588
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS05
GHS07
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Talc, not containing asbestiform fibres | 14807-96-6 | 10 - 30% | No |
| crystalline silica, respirable powder (>10 microns) | 14808-60-7 | 10 - 30% | No |
| Epoxy Resin (700<MW<=1100) | 25036-25-3 | 10 - 30% | No |
| xylene | 1330-20-7 | 7 - 13% | No |
| bis-[4-(2,3-epoxipropoxi)phenyl] propane | 1675-54-3 | 3 - 7% | No |
| benzyl alcohol | 100-51-6 | 3 - 7% | No |
| aluminium powder (stabilised) | 7429-90-5 | 1 - 5% | No |
| 2-methylpropan-1-ol | 78-83-1 | 1 - 5% | No |
| Hydrocarbons, C10-C13, n-alkanes, isoalkanes, cyclics, < 2% aromatics ethylbenzene | 64742-48-9 | 1 - 5% | No |
| Benzene, ethyl- | 100-41-4 | 1 - 5% | No |
| crystalline silica, respirable powder (<10 microns) | 14808-60-7 | 1 - 5% | No |
| Octadecanamide, N, N'-1,6-hexanediylbis[12-hydroxy- | 55349-01-4 | 1 - 5% | No |
There are no additional ingredients present which, within the current knowledge of the supplier and in the concentrations applicable, are classified as hazardous to health or the environment and hence require reporting in this section.
Notes
Ranges if listed above for hazardous ingredient(s) are prescribed ranges.
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove to fresh air. Keep person warm and at rest. If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel.
Symptoms: Harmful if inhaled. May cause respiratory irritation. Adverse symptoms may include the following: respiratory tract irritation, coughing.
Remove contaminated clothing and shoes. Wash skin thoroughly with soap and water or use recognized skin cleanser.
Symptoms: Causes skin irritation. Defatting to the skin. May cause an allergic skin reaction. Adverse symptoms may include the following: pain or irritation, redness, dryness, cracking, blistering may occur.
Check for and remove any contact lenses. Immediately flush eyes with running water for at least 15 minutes, keeping eyelids open. Seek immediate medical attention.
Symptoms: Causes serious eye damage. Adverse symptoms may include the following: pain, watering, redness.
If swallowed, seek medical advice immediately and show this container or label. Keep person warm and at rest. Do NOT induce vomiting.
Symptoms: No known significant effects or critical hazards. Adverse symptoms may include the following: stomach pains.
Immediate Medical Attention
Seek immediate medical attention for eye contact. In case of inhalation of decomposition products in a fire, symptoms may be delayed.
Medical Treatment
No specific treatment.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use dry chemical, CO₂, water spray (fog) or foam.
Do not use water jet.
Flammable liquid and vapor. Runoff to sewer may create fire or explosion hazard. In a fire or if heated, a pressure increase will occur and the container may burst, with the risk of a subsequent explosion.
Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training. Move containers from fire area if this can be done without risk. Use water spray to keep fire-exposed containers cool.
Firefighter Protection
Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
No action shall be taken involving any personal risk or without suitable training. Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilled material. Shut off all ignition sources. No flares, smoking or flames in hazard area. Do not breathe vapor or mist. Provide adequate ventilation.
Stop leak if without risk. Move containers from spill area. Use spark-proof tools and explosion-proof equipment. Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material and place in an appropriate waste disposal container. Dispose of via a licensed waste disposal contractor.
Stop leak if without risk. Move containers from spill area. Use spark-proof tools and explosion-proof equipment. Approach release from upwind. Prevent entry into sewers, water courses, basements or confined areas. Wash spillages into an effluent treatment plant or proceed as follows. Contain and collect spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations (see Section 13). Dispose of via a licensed waste disposal contractor.
Avoid dispersal of spilled material and runoff and contact with soil, waterways, drains and sewers.
Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material and place in an appropriate waste disposal container.
Materials: inert dry material, non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth
Related Products
Similar products with comparable safety profiles
SIGMACOVER 280 BASE REDBROWN
---
INTERSHIELD 300HS ALUMINIUM PART A
---
SIGMACOVER 295 HARDENER
---
ALUMINIUM RESISTANT COATING MATERIAL
---
MASTER ALLOY ALUMINIUM-BERYLLIUM
---
MASTER ALLOY ALUMINIUM-BERYLLIUM
---
ALUMINIUM POWDER COATED 4.1 - stabilized
CAS: 7429-90-5
BONDERITE M-CR ALUMIGOLD C AERO
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Put on appropriate personal protective equipment (see Section 8). Persons with a history of skin sensitization problems should not be employed in any process in which this product is used. Avoid exposure - obtain special instructions before use. Do not handle until all safety precautions have been read and understood. Do not get in eyes or on skin or clothing. Do not breathe vapor or mist. Do not ingest. Use only with adequate ventilation. Wear appropriate respirator when ventilation is inadequate. Do not enter storage areas and confined spaces unless adequately ventilated. Keep in the original container or an approved alternative made from a compatible material, kept tightly closed when not in use. Store and use away from heat, sparks, open flame or any other ignition source. Use explosion-proof electrical (ventilating, lighting and material handling) equipment. Use only non-sparking tools. Take precautionary measures against electrostatic discharges. Empty containers retain product residue and can be hazardous. Do not reuse container.
Store between the following temperatures: 0 to 35°C (32 to 95°F). Store in accordance with local regulations. Store in a segregated and approved area. Store in original container protected from direct sunlight in a dry, cool and well-ventilated area, away from incompatible materials (see Section 10) and food and drink. Store locked up. Eliminate all ignition sources. Separate from oxidizing materials. Keep container tightly closed and sealed until ready for use. Containers that have been opened must be carefully resealed and kept upright to prevent leakage. Do not store in unlabeled containers. Use appropriate containment to avoid environmental contamination.
Wash hands thoroughly after handling. Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Remove contaminated clothing and protective equipment before entering eating areas.
Store and use away from heat, sparks, open flame or any other ignition source. Use explosion-proof electrical (ventilating, lighting and material handling) equipment. Use only non-sparking tools. Take precautionary measures against electrostatic discharges.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is stable.
No specific test data related to reactivity available for this product or its ingredients.
Under normal conditions of storage and use, hazardous reactions will not occur.
When exposed to high temperatures may produce hazardous decomposition products. Refer to protective measures listed in sections 7 and 8.
Keep away from the following materials to prevent strong exothermic reactions: oxidizing agents, strong alkalis, strong acids.
Depending on conditions, decomposition products may include the following materials: carbon oxides nitrogen oxides metal oxide/oxides
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN1263
- Shipping Name
- PAINT
- Transport Class
- 3
- Packing Group
- III
Transport within user's premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.
Transport within user's premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.
Transport within user's premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is SIGMACOVER 350 BASE ALUMINIUM known by?
SIGMACOVER 350 BASE ALUMINIUM is also known as: 00347321; 00350667
What is the hazard signal word for SIGMACOVER 350 BASE ALUMINIUM?
The signal word is danger.
What is the physical form of SIGMACOVER 350 BASE ALUMINIUM?
SIGMACOVER 350 BASE ALUMINIUM is a liquid. with silver-white. color. It has aromatic. odor.
What is SIGMACOVER 350 BASE ALUMINIUM used for?
Professional applications, Used by spraying. Coating.
What are the hazard statements for SIGMACOVER 350 BASE ALUMINIUM?
This substance has 9 hazard statements:
- H226: Flammable liquid and vapor.
- H315: Causes skin irritation.
- H316: Prolonged or repeated contact may dry skin and cause irritation.
- H317: May cause an allergic skin reaction.
- H318: Causes serious eye damage.
- H332: Harmful if inhaled.
- H335: May cause respiratory irritation.
- H350: May cause cancer.
- H372: Causes damage to organs through prolonged or repeated exposure. (hearing organs)
What is the melting point of SIGMACOVER 350 BASE ALUMINIUM?
The melting point is Not available. and the boiling point is >37.78°C (>100°F).