Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- TEROSON PV 1550 ACD known as Sealant
- Product Code
- 1057188
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Sealant
Uses advised against
None identified
Manufacturers & Suppliers
Henkel Corporation
manufacturer
One Henkel Way, Rocky Hill, Connecticut 06067
+1 (860) 571-5100
www.henkelna.com
Emergency Contacts
Poison Control Center
1-877-671-4608
Poison Control Center
1-303-592-1711
CHEMTREC
1-800-424-9300
CHEMTREC
1-703-527-3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Diisononyl phthalate | 28553-12-0 | 30 - 60% | No |
| Polyvinyl chloride | 9002-86-2 | 10 - 30% | No |
| Glass, oxide, chemicals | 65997-17-3 | 10 - 30% | No |
| Hydrotreated heavy naphtha | 64742-48-9 | 1 - 5% | No |
| Zinc oxide | 1314-13-2 | 1 - 5% | No |
| Calcium carbonate | 471-34-1 | 1 - 5% | No |
| Calcium oxide | 1305-78-8 | 1 - 5% | No |
| Titanium dioxide | 13463-67-7 | 1 - 5% | No |
| Polyamide resin | 68410-23-1 | 1 - 5% | No |
IDH number: 1057188 Product name: TEROSON PV 1550 ACD known as
First Aid Measures
Emergency procedures for chemical exposure incidents
If inhaled, immediately remove the affected person to fresh air. If symptoms develop and persist, get medical attention.
Immediately wash skin thoroughly with soap and water. If symptoms develop and persist, get medical attention.
In case of contact with the eyes, rinse immediately with plenty of water for 15 minutes, and seek immediate medical attention.
Get immediate medical attention. Do not induce vomiting.
Immediate Medical Attention
Get immediate medical attention.
Medical Treatment
Treat symptomatically and supportively.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water spray (fog), foam, dry chemical or carbon dioxide.
None expected.
Wear full protective clothing. Wear self-contained breathing apparatus.
Firefighter Protection
Wear full protective clothing. Wear self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Use personal protection recommended in Section 8, isolate the hazard area and deny entry to unnecessary and unprotected personnel.
Prevent further leakage or spillage. Do not allow product to enter sewer or waterways.
Scrape or shovel material into recovery container.
Materials: recovery container
Related Products
Similar products with comparable safety profiles
TEROSON PV 1185 A PAINT SHOP SEALANT
---
TEROSON PV 1095 PAINT SHOP SEALANT
---
TEROSON PV 1095 V PAINT SHOP SEALANT known as TEROLAN SA-1095-V
---
TEROSON PV 1095 C PAINT SHOP SEALANT known as TEROLAN SA-1095C
---
TEROSON PV 4600 BODY SHOP METAL SEALANT known as TEROSTAT 4600 MS-CD 473H P Sealant
---
TEROSON PV 1030.3D W PAINT SHOP SEALANT
---
TEROSON PV 1035.1 PAINT SHOP SEALANT known as TEROLAN 1035.1
---
TEROSON PV 1272 Non-Expanding Sealer known as TEROSTAT 06-1272
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid contact with eyes, skin and clothing. Wash thoroughly after handling. Avoid breathing fumes if this product is used at high temperatures. Use only with adequate ventilation. Do not take internally. For industrial use only.
Keep container tightly closed and in a cool, well-ventilated place away from incompatible materials.
Wash thoroughly after handling.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable at normal conditions.
Not available.
None under normal processing.
Heat, flames, sparks and other sources of ignition.
This product may react with strong oxidizing agents.
Irritating and/or toxic fumes and gases may be emitted upon the product's decomposition. Upon decomposition, this product emits carbon monoxide, carbon dioxide and/or low molecular weight hydrocarbons. Heat and processing may result in the release of low levels of vinyl chloride.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 3077
- Shipping Name
- RQ, Environmentally hazardous substance, solid, n.o.s.
- Transport Class
- 9
- Packing Group
- III
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for TEROSON PV 1550 ACD known as Sealant?
The signal word is warning.
What is the physical form of TEROSON PV 1550 ACD known as Sealant?
TEROSON PV 1550 ACD known as Sealant is a solid with white color. It has mild odor.
What is TEROSON PV 1550 ACD known as Sealant used for?
Sealant
What are the hazard statements for TEROSON PV 1550 ACD known as Sealant?
This substance has 3 hazard statements:
- H317: MAY CAUSE AN ALLERGIC SKIN REACTION.
- H319: CAUSES EYE IRRITATION.
- H335: MAY CAUSE RESPIRATORY IRRITATION.
What is the melting point of TEROSON PV 1550 ACD known as Sealant?
The melting point is Not applicable and the boiling point is > 104.4 °C (> 219.9 °F) calculated.