NextSDS Logo
Safety Data Sheet EN

BONDERITE L-FM DFL 520-2M FORMING LUBRICANT ACHESON known as MULTAN DFL 520-2M

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
BONDERITE L-FM DFL 520-2M FORMING LUBRICANT ACHESON known as MULTAN DFL 520-2M

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Dry film lubricant

Uses advised against

None identified

Manufacturers & Suppliers

Henkel Corporation logo

Henkel Corporation

manufacturer

One Henkel Way, Rocky Hill, Connecticut 06067

+1 (860) 571-5100

www.henkelna.com

Emergency Contacts

Poison Control Center

1-877-671-4608

Poison Control Center

1-303-592-1711

CHEMTREC

1-800-424-9300

CHEMTREC

1-703-527-3887

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Repr. Cat. 2 H361

GHS Pictograms

GHS08 - Serious health hazard

GHS08

Hazard Statements

H361 SUSPECTED OF DAMAGING FERTILITY OR THE UNBORN CHILD.

Precautionary Statements

P201 Obtain special instructions before use.
P202 Do not handle until all safety precautions have been read and understood.
P280 Wear protective gloves, clothing, eye and face protection.
P308 + P313 IF exposed or concerned: Get medical attention.
P405 Store locked up.
P501 Dispose of contents and/or container according to Federal, State/Provincial and local governmental regulations.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Boric acid 10043-35-3 5 - 10% Yes
Fatty acids, tallow, sodium salts 8052-48-0 5 - 10% Yes

Notes

* Exact percentages may vary or are trade secret. Concentration range is provided to assist users in providing appropriate protections.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

If inhaled, immediately remove the affected person to fresh air. If symptoms develop and persist, get medical attention.

Skin contact

For skin contact flush with large amounts of water. If adverse health effects develop seek medical attention.

Eye contact

In case of contact with eyes, rinse immediately with plenty of water and seek medical advice.

Ingestion

Get medical attention. DO NOT induce vomiting unless directed to do so by medical personnel.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water spray (fog), foam, dry chemical or carbon dioxide.

Unsuitable media

Not available.

Specific hazards

May liberate large quantities of dense, foul-smelling smoke which may contain unidentified toxic gasses.

Instructions

Wear self-contained breathing apparatus. Wear full protective clothing.

Firefighter Protection

Wear self-contained breathing apparatus. Wear full protective clothing.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Isolate the hazard area and deny entry to unnecessary and unprotected personnel.

Environmental

Prevent further leakage or spillage if safe to do so. Wear appropriate protective equipment and clothing during clean-up.

Cleanup methods

Sweep up or gather material and place in appropriate container for disposal. Wash spill area thoroughly.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid contact with eyes, skin and clothing. Avoid breathing vapors or mists of this product. Provide adequate ventilation. Wash thoroughly after handling. Do not take internally.

Storage

Keep closed in a cool, dry area. Thaw and mix thoroughly if frozen.

Hygiene

Wash thoroughly after handling.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Odor
Mild
Physical State
Liquid
Lower Explosive Limit
Not available.
Decomposition Temperature
Not available.
Partition Coefficient
Not determined
Boiling Point
100 °C (212°F)calculated
Colour
Off white
Solubility In Water
---
Kinematic Viscosity
Not available.
State Under Standard Conditions
---
Solubility
Complete Water
Ph
7.9 - 8.9
Odor Threshold
Not available.
Crystallisation Point
---
Flash Point
Not applicable
Metal Corrosion
---
Melting Point
Not determined
Voc Content
Not determined
Evaporation Rate
Not determined
Properties Status
---
Relative Evaporation Rate
---
Cloud Point
---
Solidification Point
---
Physical State Data
liquid
Vapor Pressure
Not applicable
Upper Explosive Limit
Not available.
Colour Intensity
---
Form
---
Dynamic Viscosity
Not available.
Vapor Density
---
Softening Point
---
Molecular Weight
---
Solubility In Fat
---
Relative Density
1.03 - 1.06 at 75 °F (23.89 °C)
Appearance
---
Density
---
Auto Ignition Temperature
Not applicable
Explosive Limits
---
Flammability
Not applicable
Freezing Point
---
Bulk Density
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable at normal conditions.

Reactivity

This product may react with strong acids or oxidizing agents.

Hazardous reactions

None under normal processing.

Avoid

None identified.

Incompatible

Not available.

Decomposition

Upon decomposition, this product emits carbon monoxide, carbon dioxide, and boron oxides.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for BONDERITE L-FM DFL 520-2M FORMING LUBRICANT ACHESON known as MULTAN DFL 520-2M?

The signal word is warning.

What is the physical form of BONDERITE L-FM DFL 520-2M FORMING LUBRICANT ACHESON known as MULTAN DFL 520-2M?

BONDERITE L-FM DFL 520-2M FORMING LUBRICANT ACHESON known as MULTAN DFL 520-2M is a liquid with off white color. It has mild odor.

What is the solubility of BONDERITE L-FM DFL 520-2M FORMING LUBRICANT ACHESON known as MULTAN DFL 520-2M?

Complete Water

What is BONDERITE L-FM DFL 520-2M FORMING LUBRICANT ACHESON known as MULTAN DFL 520-2M used for?

Dry film lubricant

What are the hazard statements for BONDERITE L-FM DFL 520-2M FORMING LUBRICANT ACHESON known as MULTAN DFL 520-2M?

This substance has 1 hazard statement:

  • H361: SUSPECTED OF DAMAGING FERTILITY OR THE UNBORN CHILD.

What is the melting point of BONDERITE L-FM DFL 520-2M FORMING LUBRICANT ACHESON known as MULTAN DFL 520-2M?

The melting point is Not determined and the boiling point is 100 °C (212°F)calculated.