Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
TECHNOMELT PUR O-LUB
Product Form
High temperature grease
Product Code
397796

Regulatory Identifiers

CAS Number
N/A

Manufacturers & Suppliers

Henkel Corporation logo

Henkel Corporation

manufacturer

One Henkel Way, Rocky Hill, Connecticut 06067

+1 (860) 571-5100

http://www.henkelna.com

Emergency Contacts

Poison Control Center

1-877-671-4608

Poison Control Center

1-303-592-1711

CHEMTREC

1-800-424-9300

CHEMTREC

1-703-527-3887

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Precautionary Statements

Not prescribed
Not prescribed
Not prescribed
Not prescribed

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

All components of this product are non-hazardous.

Notes

None of the components are hazardous.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

If inhaled, immediately remove the affected person to fresh air. If symptoms develop and persist, get medical attention.

Skin contact

Immediately wash skin thoroughly with soap and water. If symptoms develop and persist, get medical attention.

Eye contact

In case of contact with the eyes, rinse immediately with plenty of water for 15 minutes, and seek immediate medical attention.

Ingestion

Get immediate medical attention. Do not induce vomiting.

Immediate Medical Attention

Get immediate medical attention.

Medical Treatment

Treat symptomatically and supportively.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use media appropriate for surrounding material.

Specific hazards

Formation of toxic gases is possible during heating or in fires.

Instructions

Wear full protective clothing. Wear self-contained breathing apparatus.

Firefighter Protection

Wear full protective clothing. Wear self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Use personal protection recommended in Section 8, isolate the hazard area and deny entry to unnecessary and unprotected personnel.

Environmental

Prevent further leakage or spillage if safe to do so. Wear appropriate protective equipment and clothing during clean-up. Do not allow product to enter sewer or waterways.

Cleanup methods

Absorb spill with inert material. Shovel material into appropriate container for disposal.

Materials: inert material

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid contact with eyes, skin and clothing. Wash thoroughly after handling. Avoid breathing vapors or mists of this product. For industrial use only. Do not take internally.

Storage

Keep container tightly closed and in a cool, well-ventilated place away from incompatible materials.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Provide local and general exhaust ventilation to effectively remove and prevent buildup of any vapors or mists generated from the handling of this product.

Hands

Gloves should be tested to determine suitability for prolonged contact. Suitable glove materials may include: Nitrile gloves. Neoprene gloves.

Eyes

Wear chemical goggles; face shield (if splashing is possible).

Respiratory

If ventilation is not sufficient to effectively prevent buildup of aerosols, mists or vapors, appropriate NIOSH/MSHA respiratory protection must be provided. Air purifying respirators must use N, R, or P series filters. The filter must be NIOSH classification 95, 99, or 100. A NIOSH-approved air-purifying respirator with an organic vapor cartridge or canister may be permissible under certain circumstances where airborne concentrations are expected to exceed exposure limits. Protection provided by air-purifying respirators is limited. Use a positive-pressure, air-supplied respirator if there is any potential for uncontrolled release, exposure levels are not known or any other circumstances where air-purifying respirators may not provide adequate protection.

Skin/Body

Use of protective coveralls and long sleeves is recommended.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Paste
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
brownish
Colour Intensity
---
Form
---
Odor
Mild
Odor Threshold
Not available.
Ph
Not applicable
Melting Point
Not available.
Boiling Point
Not available.
Flash Point
Not applicable
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not available.
Vapor Pressure
Not available.
Vapor Density
---
Relative Density
0.9000 at 24.00 °C (75.2 °F)
Bulk Density
---
Density
---
Flammability
Not applicable
Upper Explosive Limit
Not available.
Lower Explosive Limit
Not available.
Explosive Limits
---
Auto Ignition Temperature
Not available.
Decomposition Temperature
Not available.
Solubility
---
Partition Coefficient
---
Solubility In Water
Insoluble
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
1,200 - 2,200 mPa.s
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions of storage and use.

Reactivity

Not available.

Hazardous reactions

None under normal processing.

Avoid

Keep away from heat, ignition sources and incompatible materials.

Incompatible

This product may react with strong acids or oxidizing agents.

Decomposition

Upon decomposition, this product emits carbon monoxide, carbon dioxide and/or low molecular weight hydrocarbons. Oxides of nitrogen.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for TECHNOMELT PUR O-LUB?

The signal word is no signal word.

What is the physical form of TECHNOMELT PUR O-LUB?

TECHNOMELT PUR O-LUB is a paste with brownish color. It has mild odor.

What is the melting point of TECHNOMELT PUR O-LUB?

The melting point is Not available. and the boiling point is Not available..