NextSDS Logo
Safety Data Sheet EN

BONDERITE M-NT AUTOPREP CF CONVERSION COATING known as AUTO PREP CF

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
BONDERITE M-NT AUTOPREP CF CONVERSION COATING known as AUTO PREP CF
Product Code
967209

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Conversion coating

Uses advised against

None identified

Manufacturers & Suppliers

Henkel Corporation logo

Henkel Corporation

manufacturer

One Henkel Way, Rocky Hill, Connecticut 06067

+1 (860) 571-5100

http://www.henkelna.com

Emergency Contacts

Poison Control Center

1-877-671-4608

Poison Control Center

1-303-592-1711

CHEMTREC

1-800-424-9300

CHEMTREC

1-703-527-3887

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Eye Irrit. Cat. 2A H319

GHS Pictograms

GHS07 - Health hazard

GHS07

Hazard Statements

H319 CAUSES SERIOUS EYE IRRITATION.

Precautionary Statements

P264 Wash affected area thoroughly after handling.
P280 Wear eye and face protection.
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P337 + P313 If eye irritation persists: Get medical attention.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Hexafluorotitanic acid 17439-11-1 0.1 - 1% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove person immediately to fresh air. Seek medical attention if symptoms develop or persist. If breathing is difficult, give oxygen. Trained personnel should administer 2.5% calcium gluconate through a nebulizer for 20 minutes.

Skin contact

Remove contaminated clothing and footwear while rinsing the affected area with large amounts of running water for at least 15 minutes. GET IMMEDIATE MEDICAL ATTENTION. If iced solution of 0.13% aqueous Benzalkonium Chloride (Zephiran) or 2.5% calcium gluconate gel is available, rinsing may be limited to 5 minutes, with the soak solution or gel applied as soon as the rinsing is stopped. If using calcium gluconate gel, it should be continuously re-applied and massaged into the affected area until pain has been relieved for at least 30 minutes. If Benzalkonium Chloride (Zephiran) or calcium gluconate gel is not available, rinsing must continue until medical treatment is provided.

Eye contact

Immediately flush affected eye with large amounts of gently flowing water or 0.9% sterile saline solution for at least 15 minutes. Hold eyelid wide open. Get immediate medical attention. Eye flushing should continue during transportation to a doctor.

Ingestion

Get immediate medical attention. Do not induce vomiting. Attempt immediate administration of a fluoride binding substance: milk, chewable calcium carbonate tablets or 4-8 ounces (120-240 ml) of milk of magnesia or a liquid antacid. Avoid large amounts of liquid as it may induce vomiting. Never give anything by mouth to an unconscious person.

Immediate Medical Attention

Get immediate medical attention.

Medical Treatment

Treatment of hypocalcemia associated with corrosive fluoride compounds exposure may be corrected by intravenous calcium gluconate or calcium chloride. Treatment of hypomagnesemia may be corrected by intravenous magnesium sulfate.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water spray (fog), foam, dry chemical or carbon dioxide.

Instructions

Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.

Firefighter Protection

Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Use personal protection recommended in Section 8, isolate the hazard area and deny entry to unnecessary and unprotected personnel.

Environmental

Prevent further leakage or spillage if safe to do so.

Cleanup methods

Absorb spill with inert material. Shovel material into appropriate container for disposal.

Materials: inert material

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid contact with eyes, skin and clothing. Do not breathe gas/fumes/vapor/spray. Wash thoroughly after handling. Do not take internally. For industrial use only.

Storage

Keep container tightly closed and in a cool, well-ventilated place away from incompatible materials. Thaw and mix thoroughly if frozen.

Hygiene

Wash thoroughly after handling.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Cloud Point
---
Boiling Point
> 210 °F (> 98.9 °C) None
Evaporation Rate
Not available.
Bulk Density
---
Kinematic Viscosity
Not available.
Odor Threshold
Not available.
Ph
2.4
Appearance
Light amber
Colour
Light amber
Melting Point
Not available.
Vapor Density
---
Form
---
Density
---
Softening Point
---
Voc Content
Not applicable
State Under Standard Conditions
---
Metal Corrosion
---
Vapor Pressure
Not determined
Molecular Weight
---
Partition Coefficient
Not available.
Solidification Point
---
Colour Intensity
---
Flash Point
> 93 °C (> 199.4 °F) HST-US 027F
Flammability
Not applicable
Explosive Limits
---
Lower Explosive Limit
Not applicable
Physical State
Liquid
Odor
Odourless / Odorless
Properties Status
---
Solubility In Fat
---
Physical State Data
liquid
Decomposition Temperature
Not available.
Dynamic Viscosity
Not available.
Relative Density
1.012 at 20 °C (68°F)
Solubility
fully soluble Water
Relative Evaporation Rate
---
Auto Ignition Temperature
Not available.
Upper Explosive Limit
Not applicable
Crystallisation Point
---
Solubility In Water
fully soluble
Freezing Point
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable at normal conditions.

Reactivity

This product may react with strong alkalies.

Hazardous reactions

None under normal processing.

Avoid

Store away from incompatible materials.

Incompatible

This material will react with glass, concrete, certain metals, silica containing materials, rubber, leather, and many organics.

Decomposition

Upon decomposition, this product emits carbon monoxide, carbon dioxide and/or low molecular weight hydrocarbons. May liberate hydrogen fluoride. Oxides of phosphorus.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for BONDERITE M-NT AUTOPREP CF CONVERSION COATING known as AUTO PREP CF?

The signal word is warning.

What is the physical form of BONDERITE M-NT AUTOPREP CF CONVERSION COATING known as AUTO PREP CF?

BONDERITE M-NT AUTOPREP CF CONVERSION COATING known as AUTO PREP CF is a liquid appearing as light amber with light amber color. It has odourless / odorless odor.

What is the solubility of BONDERITE M-NT AUTOPREP CF CONVERSION COATING known as AUTO PREP CF?

fully soluble Water

What is BONDERITE M-NT AUTOPREP CF CONVERSION COATING known as AUTO PREP CF used for?

Conversion coating

What are the hazard statements for BONDERITE M-NT AUTOPREP CF CONVERSION COATING known as AUTO PREP CF?

This substance has 1 hazard statement:

  • H319: CAUSES SERIOUS EYE IRRITATION.

What is the melting point of BONDERITE M-NT AUTOPREP CF CONVERSION COATING known as AUTO PREP CF?

The melting point is Not available. and the boiling point is > 210 °F (> 98.9 °C) None.