NextSDS Logo
Safety Data Sheet EN

BONDERITE M-PT 3416 REACTION RINSE known as AQUENCE 3416 RXN RINSE

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
BONDERITE M-PT 3416 REACTION RINSE known as AQUENCE 3416 RXN RINSE
Product Code
643678

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Coating

Uses advised against

None identified

Manufacturers & Suppliers

Henkel Corporation logo

Henkel Corporation

manufacturer

One Henkel Way, Rocky Hill, Connecticut 06067

+1 (860) 571-5100

www.henkelna.com

Emergency Contacts

CHEMTREC

1-703-527-3887

Poison Control Center

1-877-671-4608

Poison Control Center

1-303-592-1711

CHEMTREC

1-800-424-9300

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Precautionary Statements

Prevention: Not prescribed
Response: Not prescribed
Storage: Not prescribed
Disposal: Not prescribed

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Notes

Exact percentages may vary or are trade secret. Concentration range is provided to assist users in providing appropriate protections.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

If mist or vapor of this product is inhaled, remove person immediately to fresh air. Seek medical attention if symptoms develop or persist.

Skin contact

Immediately wash skin thoroughly with soap and water. If symptoms develop and persist, get medical attention.

Eye contact

Immediately flush eyes with plenty of water for at least 15 minutes. Get medical attention.

Ingestion

Get immediate medical attention. Do not induce vomiting.

Immediate Medical Attention

Get immediate medical attention.

Medical Treatment

Treat symptomatically and supportively.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use media appropriate for surrounding material.

Unsuitable media

Not available.

Specific hazards

This product is an aqueous mixture which will not burn.

Instructions

Wear full protective clothing. Wear self-contained breathing apparatus.

Firefighter Protection

Wear full protective clothing. Wear self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

isolate the hazard area and deny entry to unnecessary and unprotected personnel

Environmental

Prevent further leakage or spillage if safe to do so.

Cleanup methods

Absorb spill with inert material. Shovel material into appropriate container for disposal.

Materials: inert material

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid contact with eyes, skin and clothing. Avoid breathing vapors or mists of this product. Do not take internally. For industrial use only.

Storage

store between 40 °F (4.4 °C) and 100 °F (37.8 °C) Keep container tightly closed and in a cool, well-ventilated place away from incompatible materials. Do not freeze.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Provide local and general exhaust ventilation to effectively remove and prevent buildup of any vapors or mists generated from the handling of this product.

Hands

Chemical resistant, impermeable gloves.

Eyes

Wear chemical goggles; face shield (if splashing is possible).

Respiratory

If ventilation is not sufficient to effectively prevent buildup of aerosols, mists or vapors, appropriate NIOSH/MSHA respiratory protection must be provided. When workplace hazards warrant the use of a respirator, appropriate respirators must be used, and a program that follows 29 CFR 1910.134 must be followed.

Skin/Body

Use of impervious apron and boots are recommended.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
Clear
Colour Intensity
---
Form
---
Odor
ammoniacal
Odor Threshold
Not available.
Ph
8.5 - 9.5
Melting Point
Not available.
Boiling Point
> 210 °F (> 98.9 °C) calculated
Flash Point
> 100 °C (> 212°F) calculated
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not determined
Vapor Pressure
Not determined
Vapor Density
---
Relative Density
1.01 - 1.02
Bulk Density
---
Density
---
Flammability
Not applicable
Upper Explosive Limit
Not applicable
Lower Explosive Limit
Not applicable
Explosive Limits
---
Auto Ignition Temperature
Not applicable
Decomposition Temperature
Not available.
Solubility
Complete
Partition Coefficient
Not available.
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
---
Voc Content
Not determined
Metal Corrosion
---
Dynamic Viscosity
Not available.
Kinematic Viscosity
Not available.
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable at normal conditions.

Reactivity

This product may react with strong reducing agents.

Hazardous reactions

None under normal processing.

Avoid

Store away from incompatible materials.

Incompatible

Oxidizers.

Decomposition

Upon decomposition, this product may yield gaseous nitrogen oxides, carbon monoxide, carbon dioxide and/or low molecular weight hydrocarbons.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for BONDERITE M-PT 3416 REACTION RINSE known as AQUENCE 3416 RXN RINSE?

The signal word is no signal word.

What is the physical form of BONDERITE M-PT 3416 REACTION RINSE known as AQUENCE 3416 RXN RINSE?

BONDERITE M-PT 3416 REACTION RINSE known as AQUENCE 3416 RXN RINSE is a liquid with clear color. It has ammoniacal odor.

What is the solubility of BONDERITE M-PT 3416 REACTION RINSE known as AQUENCE 3416 RXN RINSE?

Complete

What is BONDERITE M-PT 3416 REACTION RINSE known as AQUENCE 3416 RXN RINSE used for?

Coating

What is the melting point of BONDERITE M-PT 3416 REACTION RINSE known as AQUENCE 3416 RXN RINSE?

The melting point is Not available. and the boiling point is > 210 °F (> 98.9 °C) calculated.