NextSDS Logo
Safety Data Sheet EN

LOCTITE ECCOBOND FP4450 known as 10CC SEMI ENCAP ROCKWELL - 40CD

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
LOCTITE ECCOBOND FP4450 known as 10CC SEMI ENCAP ROCKWELL - 40CD
Product Code
555614

Regulatory Identifiers

CAS Number
N/A

Identified Uses

1-c- epoxide adhesive

Uses advised against

None identified

Manufacturers & Suppliers

Henkel Corporation logo

Henkel Corporation

manufacturer

One Henkel Way, Rocky Hill, Connecticut 06067

+1 (860) 571-5100

http://www.henkelna.com

Emergency Contacts

Poison Control Center

1-877-671-4608

Poison Control Center

1-303-592-1711

CHEMTREC

1-800-424-9300

CHEMTREC

1-703-527-3887

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Skin Irrit. Cat. 2
Eye Dam. Cat. 1
Resp. Sens. Cat. 1
Skin Sens. Cat. 1
Muta. Cat. 2
STOT SE Cat. 3
STOT RE Cat. 1
STOT RE Cat. 2

GHS Pictograms

GHS05 - Corrosive

GHS05

GHS07 - Health hazard

GHS07

GHS08 - Serious health hazard

GHS08

Hazard Statements

H315 CAUSES SKIN IRRITATION.
H317 MAY CAUSE AN ALLERGIC SKIN REACTION.
H318 CAUSES SERIOUS EYE DAMAGE.
H334 MAY CAUSE ALLERGY OR ASTHMA SYMPTOMS OR BREATHING DIFFICULTIES IF INHALED.
H335 MAY CAUSE RESPIRATORY IRRITATION.
H341 SUSPECTED OF CAUSING GENETIC DEFECTS.
H372 CAUSES DAMAGE TO ORGANS THROUGH PROLONGED OR REPEATED EXPOSURE.
H372 MAY CAUSE DAMAGE TO ORGANS THROUGH PROLONGED OR REPEATED EXPOSURE.

Precautionary Statements

P201 Obtain special instructions before use.
P202 Do not handle until all safety precautions have been read and understood.
P233 Keep container tightly closed.
P261 Do not breathe vapors, mist, or spray.
P264 Wash affected area thoroughly after handling.
P270 Do not eat, drink or smoke when using this product.
P271 Use only outdoors or in a well-ventilated area.
P272 Contaminated work clothing should not be allowed out of the workplace.
P280 Wear protective gloves, clothing, eye and face protection.
P285 In case of inadequate ventilation wear respiratory protection.
P304 + P341 IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing.
P308 + P313 IF exposed or concerned: Get medical attention.
P312 Call a POISON CENTER or physician if you feel unwell.
P333 + P313 If skin irritation or rash occurs: Get medical attention.
P338 Remove contact lenses, if present and easy to do. Continue rinsing.
P351 IF IN EYES: Rinse cautiously with water for several minutes.
P352 IF ON SKIN: Wash with plenty of water.
P362 Take off contaminated clothing.
P403 Store in a well-ventilated place.
P405 Store locked up.
P501 Dispose of contents and/or container according to Federal, State/Provincial and local governmental regulations.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Silica, amorphous, naturally 60676-86-0 60 - 80% No
hexahydromethylphthalic anhydride 25550-51-0 10 - 30% No
Silicon dioxide 7631-86-9 5 - 10% No
Epichlorohydrin-4,4'-isopropylidene diphenol resin 25068-38-6 5 - 10% No
Quartz (SiO2), <1% respirable 14808-60-7 1 - 5% No
2-Propenoic acid, 2-methyl-, oxiranylmethyl ester, polymer with 2-ethylhexyl 2-propenoate and 2,2'-[(1-methylethylidene)bis(4,1-phen 121676-49-1 1 - 5% No
7-Oxabicyclo[4.1.0]hept-3-ylmethyl 7-oxabicyclo[4.1.0]heptane-3-carboxylate 2386-87-0 1 - 5% No
Substituted phthalic anhydride 34090-76-1 1 - 5% No
Bisphenol-F Epichlorhydrin resin 9003-36-5 0.1 - 1% No
Carbon black - Nano 1333-86-4 0.1 - 1% No
4,4'-carbonyldiphthalic acid compd. with 2-methyl-1H-imidazole (1:2) 172140-94-2 0.1 - 1% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Get medical attention.

Skin contact

Immediately flush skin with plenty of water (using soap, if available). Remove contaminated clothing and footwear. If symptoms develop and persist, get medical attention. Wash clothing before reuse. Thoroughly clean shoes before reuse.

Eye contact

Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Get medical attention.

Ingestion

Never give anything by mouth to an unconscious person. Get medical attention.

Immediate Medical Attention

Get medical attention.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water spray (fog), foam, dry chemical or carbon dioxide.

Specific hazards

Closed containers may rupture (due to build up of pressure) when exposed to extreme heat.

Instructions

In case of fire, keep containers cool with water spray.

Firefighter Protection

Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Use personal protection recommended in Section 8, isolate the hazard area and deny entry to unnecessary and unprotected personnel. Evacuate and ventilate spill area; dike spill to prevent entry into water system.

Environmental

Do not allow product to enter sewer or waterways.

Cleanup methods

Soak up with inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust). Store in a closed container until ready for disposal.

Materials: inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust)

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Use only with adequate ventilation. Prevent contact with eyes, skin and clothing. Do not breathe vapor and mist. Wash thoroughly after handling. Keep container closed.

Storage

Keep container tightly closed and in a cool, well-ventilated place away from incompatible materials. Keep away from heat, spark and flame.

Hygiene

Wash thoroughly after handling.

Fire prevention

Keep away from heat, spark and flame.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Softening Point
---
Molecular Weight
---
Colour Intensity
---
Relative Evaporation Rate
---
Colour
Black
Explosive Limits
---
Cloud Point
---
Boiling Point
> 200 °C (> 392°F)
Auto Ignition Temperature
Not available.
Flash Point
> 93 °C (> 199.4 °F)
Evaporation Rate
Not available.
Melting Point
Not applicable, Product is a liquid
Partition Coefficient
Not available.
Lower Explosive Limit
Not available.
Solubility
---
Solidification Point
---
Vapor Pressure
< 1 hPa (20 °C (68°F))
Voc Content
0 %
Physical State
Liquid, Viscous
Odor Threshold
Not available.
Odor
Aromatic
Freezing Point
---
Relative Density
1.77
Bulk Density
---
Appearance
---
Crystallisation Point
---
Decomposition Temperature
> 100 °C
Solubility In Fat
---
Solubility In Water
Not miscible or difficult to mix, Partially miscible
Physical State Data
liquid
Metal Corrosion
---
Vapor Density
> 1 20 °C
Form
---
Properties Status
---
Kinematic Viscosity
---
Ph
Not applicable, Product is non-soluble (in water).
Density
---
Upper Explosive Limit
Not available.
Dynamic Viscosity
---
State Under Standard Conditions
---
Flammability
Not applicable
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions of storage and use.

Reactivity

Not available.

Hazardous reactions

None under normal processing. Polymerization may occur at elevated temperature or in the presence of incompatible materials.

Avoid

Keep away from heat, ignition sources and incompatible materials.

Incompatible

Strong oxidizing agents. Strong reducing agents.

Decomposition

Oxides of carbon. Toxic fumes. Irritating vapors.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for LOCTITE ECCOBOND FP4450 known as 10CC SEMI ENCAP ROCKWELL - 40CD?

The signal word is danger.

What is the physical form of LOCTITE ECCOBOND FP4450 known as 10CC SEMI ENCAP ROCKWELL - 40CD?

LOCTITE ECCOBOND FP4450 known as 10CC SEMI ENCAP ROCKWELL - 40CD is a liquid, viscous with black color. It has aromatic odor.

What is LOCTITE ECCOBOND FP4450 known as 10CC SEMI ENCAP ROCKWELL - 40CD used for?

1-c- epoxide adhesive

What are the hazard statements for LOCTITE ECCOBOND FP4450 known as 10CC SEMI ENCAP ROCKWELL - 40CD?

This substance has 8 hazard statements:

  • H315: CAUSES SKIN IRRITATION.
  • H317: MAY CAUSE AN ALLERGIC SKIN REACTION.
  • H318: CAUSES SERIOUS EYE DAMAGE.
  • H334: MAY CAUSE ALLERGY OR ASTHMA SYMPTOMS OR BREATHING DIFFICULTIES IF INHALED.
  • H335: MAY CAUSE RESPIRATORY IRRITATION.
  • H341: SUSPECTED OF CAUSING GENETIC DEFECTS.
  • H372: CAUSES DAMAGE TO ORGANS THROUGH PROLONGED OR REPEATED EXPOSURE.
  • H372: MAY CAUSE DAMAGE TO ORGANS THROUGH PROLONGED OR REPEATED EXPOSURE.

What is the melting point of LOCTITE ECCOBOND FP4450 known as 10CC SEMI ENCAP ROCKWELL - 40CD?

The melting point is Not applicable, Product is a liquid and the boiling point is > 200 °C (> 392°F).