NextSDS Logo
Safety Data Sheet EN

LOCTITE TCF 1000 ALH known as Thermstrate 0.23 x 2.29

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
LOCTITE TCF 1000 ALH known as Thermstrate 0.23 x 2.29
Product Code
AL-23H-229

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Phase Change Thermal Interface Material (PCTIM)

Uses advised against

None identified

Manufacturers & Suppliers

Henkel Corporation logo

Henkel Corporation

manufacturer

One Henkel Way, Rocky Hill, Connecticut 06067

+1 (860) 571-5100

http://www.henkelna.com

Emergency Contacts

Poison Control Center

1-877-671-4608

Poison Control Center

1-303-592-1711

CHEMTREC

1-800-424-9300

CHEMTREC

1-703-527-3887

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Precautionary Statements

Not prescribed
Not prescribed
Not prescribed
Not prescribed

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Aluminum 7429-90-5 60 - 80% No
Paraffin waxes and Hydrocarbon waxes 8002-74-2 10 - 30% No
Zinc oxide 1314-13-2 10 - 30% No
Petrolatum 8009-03-8 5 - 10% No

IDH number: 764425 Product name: LOCTITE TCF 1000 ALH known as Thermstrate 0.23 x 2.29

Notes

* Exact percentages may vary or are trade secret. Concentration range is provided to assist users in providing appropriate protections.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move to fresh air. If breathing is difficult, give oxygen. If not breathing, give artificial respiration. If symptoms develop and persist, get medical attention.

Skin contact

Remove contaminated clothing and footwear. Immediately flush skin with plenty of water (using soap, if available). If symptoms develop and persist, get medical attention. Wash clothing before reuse. Thoroughly clean shoes before reuse.

Eye contact

Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Seek medical attention immediately.

Ingestion

DO NOT induce vomiting unless directed to do so by medical personnel. Never give anything by mouth to an unconscious person. If symptoms develop and persist, get medical attention.

Immediate Medical Attention

Seek medical attention immediately (for eye contact). If symptoms develop and persist, get medical attention (for other routes).

Medical Treatment

Treat symptomatically and supportively.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water spray (fog), foam, dry chemical or carbon dioxide. Use extinguishing measures appropriate to local circumstances and the surrounding environment.

Specific hazards

In case of fire, keep containers cool with water spray.

Instructions

Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear. Keep unnecessary personnel away. In case of fire, keep containers cool with water spray.

Firefighter Protection

Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

isolate the hazard area and deny entry to unnecessary and unprotected personnel.

Environmental

Do not allow product to enter sewer or waterways.

Cleanup methods

If product is spilled in the solid state, pick up and place in an appropriate waste disposal container. If product is spilled in the molten state, allow product to solidify before scraping up and disposing of in an appropriate waste disposal container.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Use only with adequate ventilation. When using do not eat, drink or smoke. Avoid contact with eyes, skin and clothing. Do not taste or swallow. Avoid breathing vapors or mists of this product. Keep container closed. Wash thoroughly after handling.

Storage

Store at or below 35 °C (95°F). Keep in a cool, well ventilated area away from heat, sparks and open flame. Keep container tightly closed until ready for use.

Hygiene

When using do not eat, drink or smoke. Wash thoroughly after handling.

Fire prevention

Keep away from heat, sparks and open flame.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Solid (coated aluminum foil substrate)
Physical State Data
solid
State Under Standard Conditions
---
Appearance
---
Colour
Gray / Grey, White
Colour Intensity
---
Form
---
Odor
---
Odor Threshold
Not available.
Ph
Not applicable, Product is non-soluble (in water).
Melting Point
60.0 °C (140°F); 60 °C (140°F) (coating compound); 482 °C (899.6 °F) (aluminum substrate)
Boiling Point
> 200 °C (> 392°F)
Flash Point
221 °C (429.8 °F) Cleveland open cup
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not available.
Vapor Pressure
< 1 hPa (20 °C (68°F))
Vapor Density
---
Relative Density
2.7 (coating compound)
Bulk Density
---
Density
---
Flammability
The product is not flammable.
Upper Explosive Limit
Not available.
Lower Explosive Limit
Not available.
Explosive Limits
---
Auto Ignition Temperature
The substance or mixture is not classified as pyrophoric.
Decomposition Temperature
Not available.
Solubility
Insoluble Water
Partition Coefficient
---
Solubility In Water
Insoluble
Solubility In Fat
---
Molecular Weight
---
Voc Content
0 %; 0 g/l
Metal Corrosion
---
Dynamic Viscosity
Not available.
Kinematic Viscosity
Not available.
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable at normal conditions.

Reactivity

Not available.

Hazardous reactions

None under normal processing.

Avoid

Exposure to moisture. Heat, flames, sparks and other sources of ignition. Store away from incompatible materials.

Incompatible

Strong acids, alkalies and oxidizing agents. Halogenated compounds. Water.

Decomposition

Oxides of carbon. Oxides of nitrogen. Metal oxide fumes. Hydrocarbons.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
UN3077
Shipping Name
Environmentally hazardous substance, solid, n.o.s. (Zinc oxide)
Transport Class
9
Packing Group
III
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for LOCTITE TCF 1000 ALH known as Thermstrate 0.23 x 2.29?

The signal word is no signal word.

What is the physical form of LOCTITE TCF 1000 ALH known as Thermstrate 0.23 x 2.29?

LOCTITE TCF 1000 ALH known as Thermstrate 0.23 x 2.29 is a solid (coated aluminum foil substrate) with gray / grey, white color.

What is the solubility of LOCTITE TCF 1000 ALH known as Thermstrate 0.23 x 2.29?

Insoluble Water

What is LOCTITE TCF 1000 ALH known as Thermstrate 0.23 x 2.29 used for?

Phase Change Thermal Interface Material (PCTIM)

What is the melting point of LOCTITE TCF 1000 ALH known as Thermstrate 0.23 x 2.29?

The melting point is 60.0 °C (140°F); 60 °C (140°F) (coating compound); 482 °C (899.6 °F) (aluminum substrate) and the boiling point is > 200 °C (> 392°F).