Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- LOCTITE STYCAST AC 5193 known as HYSOL AC5193 PINT
- Product Code
- 397666
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Epoxy resin
Uses advised against
None identified
Manufacturers & Suppliers
Henkel Corporation
manufacturer
One Henkel Way, Rocky Hill, Connecticut 06067
+1 (860) 571-5100
http://www.henkelina.com
Emergency Contacts
Poison Control Center
1-877-671-4608
Poison Control Center
1-303-592-1711
CHEMTREC
1-800-424-9300
CHEMTREC
1-703-527-3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Carbon black - Nano | 1333-86-4 | 10 - 30% | Yes |
Notes
* Exact percentages may vary or are trade secret. Concentration range is provided to assist users in providing appropriate protections.
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Get medical attention.
Immediately flush skin with plenty of water (using soap, if available). Remove contaminated clothing and footwear. If symptoms develop and persist, get medical attention. Wash clothing before reuse.
Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Get medical attention.
Do not induce vomiting. Never give anything by mouth to an unconscious person. Get medical attention.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water spray (fog), foam, dry chemical or carbon dioxide.
Not available.
Closed containers may rupture (due to build up of pressure) when exposed to extreme heat.
In case of fire, keep containers cool with water spray.
Firefighter Protection
Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Isolate the hazard area and deny entry to unnecessary and unprotected personnel.
Do not allow product to enter sewer or waterways.
Soak up with inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust). Store in a closed container until ready for disposal.
Materials: inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust)
Related Products
Similar products with comparable safety profiles
LOCTITE STYCAST HD 3719 known as HYSOL HD3719 GAL
---
LOCTITE STYCAST EE 4215 known as HYSOL EE4215 QT
---
LOCTITE STYCAST ES 4412 PTB known as HYSOL ES4412 PART B GAL
---
LOCTITE STYCAST EO 1058 known as HYSOL EO1058;GA
---
LOCTITE STYCAST ES 6510 PTA known as HYSOL ES6510 PART A 5 GAL
---
LOCTITE STYCAST ES 4412 PTA known as HYSOL ES4412 PART A GAL
---
LOCTITE STYCAST HD 0070 known as HYSOL HD0070 QT
---
LOCTITE STYCAST US 5514 PTA known as HYSOL US5514 PART A 5 GAL
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Use only with adequate ventilation. Prevent contact with eyes, skin and clothing. Do not breathe vapor and mist. Wash thoroughly after handling. Keep container closed.
Keep in a cool, well ventilated area away from heat, sparks and open flame. Keep container tightly closed until ready for use.
Wash thoroughly after handling.
Keep away from heat, sparks and open flame.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions of storage and use.
Not available.
None under normal processing.
Keep away from heat, ignition sources and incompatible materials. Direct sunlight.
Strong acids, alkalies and oxidizing agents. Amines.
Oxides of carbon. Irritating vapors.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 3082
- Shipping Name
- Environmentally hazardous substance, liquid, n.o.s. (Bisphenol-A Epichlorhydrin resin)
- Transport Class
- 9
- Packing Group
- III
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for LOCTITE STYCAST AC 5193 known as HYSOL AC5193 PINT?
The signal word is warning.
What is the physical form of LOCTITE STYCAST AC 5193 known as HYSOL AC5193 PINT?
LOCTITE STYCAST AC 5193 known as HYSOL AC5193 PINT is a liquid with black color. It has aromatic odor.
What is the solubility of LOCTITE STYCAST AC 5193 known as HYSOL AC5193 PINT?
Insoluble Water; Partially miscible ketones
What is LOCTITE STYCAST AC 5193 known as HYSOL AC5193 PINT used for?
Epoxy resin
What are the hazard statements for LOCTITE STYCAST AC 5193 known as HYSOL AC5193 PINT?
This substance has 3 hazard statements:
- H315: CAUSES SKIN IRRITATION.
- H317: MAY CAUSE AN ALLERGIC SKIN REACTION.
- H319: CAUSES SERIOUS EYE IRRITATION.
What is the melting point of LOCTITE STYCAST AC 5193 known as HYSOL AC5193 PINT?
The melting point is Not applicable, Product is a liquid and the boiling point is Not determined> 150 °C (>302°F)1,013 hPa.