Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- LOCTITE STYCAST US 5514 PTA known as HYSOL US5514 PART A 5 GAL
- Product Code
- UA5514-B80
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Part A for 2-K-Polyurethane adhesive and sealant
Uses advised against
None identified
Manufacturers & Suppliers
Henkel Corporation
manufacturer
One Henkel Way Rocky Hill, Connecticut 06067
+1 (860) 571-5100
www.henkelna.com
Emergency Contacts
Poison Control Center
1-877-671-4608
Poison Control Center
1-303-592-1711
CHEMTREC
1-800-424-9300
CHEMTREC
1-703-527-3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Methylene bis(phenylisocyanate) | 101-68-8 | 30 - 60% | Yes |
| Polymeric diphenylmethane diisocyanate | 9016-87-9 | 30 - 60% | Yes |
| Methylene bisphenyl isocyanate | 26447-40-5 | 10 - 30% | Yes |
| o-(p-Isocyanatobenzyl)phenyl isocyanate | 5873-54-1 | 1 - 5% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Get medical attention.
Symptoms: Asthmatic-type symptoms may develop and may be immediate or delayed up to several hours. Extreme asthmatic reactions can be life threatening.
Immediately flush skin with plenty of water (using soap, if available). Remove contaminated clothing and footwear. If symptoms develop and persist, get medical attention. Wash clothing before reuse.
Symptoms: This compound is a known skin sensitizer.
Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Get medical attention.
Symptoms: Workplace vapors have produced reversible corneal epithelial edema impairing vision.
Do not induce vomiting. Never give anything by mouth to an unconscious person. Get medical attention.
Immediate Medical Attention
Get medical attention.
Medical Treatment
Eyes: Stain for evidence of corneal injury. If cornea is burned, instill antibiotic steroid preparation frequently. Skin: Treat symptomatically as for contact dermatitis or thermal burns. Ingestion: Treat symptomatically. Respiratory: This compound is a known pulmonary sensitizer.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water spray (fog), foam, dry chemical or carbon dioxide.
Not available.
Sealed containers at elevated temperatures or contaminated with water may rupture explosively. During a fire, MDI vapors and other irritating, highly toxic gases may be generated by thermal decomposition or combustion.
In case of fire, keep containers cool with water spray.
Firefighter Protection
Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
isolate the hazard area and deny entry to unnecessary and unprotected personnel; Evacuate and ventilate spill area
For minor spills, absorb isocyanates with sawdust or other absorbent, shovel into suitable unsealed containers, transport to well ventilated area (outside) and treat with neutralizing solution
Large quantities may be pumped into closed, but not sealed containers for disposal.
Do not allow product to enter sewer or waterways.
Large quantities may be pumped into closed, but not sealed containers for disposal. For minor spills, absorb isocyanates with sawdust or other absorbent, shovel into suitable unsealed containers, transport to well ventilated area (outside) and treat with neutralizing solution.
Materials: sawdust or other absorbent
Related Products
Similar products with comparable safety profiles
LOCTITE STYCAST US 5536 PTA known as HYSOL US5536 PART A 5 GAL
---
LOCTITE STYCAST US 5529 PTA known as HYSOL US5529 PART A 5 GAL A3
---
LOCTITE STYCAST US 5500 PTA known as HYSOL US5500 PART A 5 GAL A3
---
LOCTITE STYCAST ES 0514 PTA known as HYSOL ES0514 PART A EU 55 GAL
---
LOCTITE STYCAST ES 6510 PTA known as HYSOL ES6510 PART A 5 GAL
---
LOCTITE STYCAST ES 4412 PTA known as HYSOL ES4412 PART A GAL
---
LOCTITE STYCAST ES 0500LC PTB known as HYSOL ES0500LC PART B 55 GAL
---
LOCTITE STYCAST ES 4412 PTB known as HYSOL ES4412 PART B GAL
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Prevent contact with eyes, skin and clothing. Do not breathe vapor and mist. Wash thoroughly after handling. Exposure to vapors of heated MDI can be extremely dangerous. Protect from moisture. Keep away from heat, spark and flame.
Store in tightly closed containers to prevent moisture contamination. Do not reseal if contamination is suspected. Store in a cool, dry place under low relative humidity, away from excessive heat.
Wash thoroughly after handling.
Keep away from heat, spark and flame.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions of storage and use.
Not available.
Rapid exothermic polymerization will occur in the presence of water, amines, alkalis and alcohols.
Keep away from heat, spark and flame. High temperatures. Contamination with water. Store away from incompatible materials.
Water. Amines. Strong bases. Alcohols. Copper alloys.
Thermal decomposition can lead to release of irritating gases and vapors. Hydrogen cyanide. MDI vapors and aerosols. Oxides of carbon. Oxides of nitrogen.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 3082
- Shipping Name
- RQ, Environmentally hazardous substance, liquid, n.o.s.
- Transport Class
- 9
- Packing Group
- III
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for LOCTITE STYCAST US 5514 PTA known as HYSOL US5514 PART A 5 GAL?
The signal word is danger.
What is the physical form of LOCTITE STYCAST US 5514 PTA known as HYSOL US5514 PART A 5 GAL?
LOCTITE STYCAST US 5514 PTA known as HYSOL US5514 PART A 5 GAL is a liquid with dark brown color. It has musty odor.
What is the solubility of LOCTITE STYCAST US 5514 PTA known as HYSOL US5514 PART A 5 GAL?
Reacts slowly with water to liberate carbon dioxide gas. Water
What is LOCTITE STYCAST US 5514 PTA known as HYSOL US5514 PART A 5 GAL used for?
Part A for 2-K-Polyurethane adhesive and sealant
What are the hazard statements for LOCTITE STYCAST US 5514 PTA known as HYSOL US5514 PART A 5 GAL?
This substance has 6 hazard statements:
- H315: CAUSES SKIN IRRITATION.
- H317: MAY CAUSE AN ALLERGIC SKIN REACTION.
- H319: CAUSES SERIOUS EYE IRRITATION.
- H332: HARMFUL IF INHALED.
- H334: MAY CAUSE ALLERGY OR ASTHMA SYMPTOMS OR BREATHING DIFFICULTIES IF INHALED.
- H372: CAUSES DAMAGE TO ORGANS THROUGH PROLONGED OR REPEATED EXPOSURE.
What is the melting point of LOCTITE STYCAST US 5514 PTA known as HYSOL US5514 PART A 5 GAL?
The melting point is Not available. and the boiling point is > 200 °C (> 392°F)1,013 hPa.