Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- BONDERITE M-NT 5700 AERO CR FREE CONVERSION COATING
- Synonyms
- ALODINE 5700
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Coating
Uses advised against
None identified
Manufacturers & Suppliers
Henkel Corporation
manufacturer
One Henkel Way, Rocky Hill, Connecticut 06067
+1 (860) 571-5100
http://www.henkelna.com
Emergency Contacts
Poison Control Center
1-877-671-4608
Poison Control Center
1-303-592-1711
CHEMTREC
1-800-424-9300
CHEMTREC
1-703-527-3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Notes
Exact percentages may vary or are trade secret. Concentration range is provided to assist users in providing appropriate protections.
First Aid Measures
Emergency procedures for chemical exposure incidents
If inhaled, immediately remove the affected person to fresh air. If symptoms develop and persist, get medical attention.
Immediately flush skin with plenty of water (using soap, if available). If symptoms develop and persist, get medical attention.
In case of contact with eyes, rinse immediately with plenty of water and seek medical advice.
Get immediate medical attention. Do not induce vomiting.
Immediate Medical Attention
Get immediate medical attention for ingestion.
Medical Treatment
Treat symptomatically and supportively.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use media appropriate for surrounding material.
Not available.
Not a fire hazard.
Wear full protective clothing. Wear self-contained breathing apparatus.
Firefighter Protection
Wear full protective clothing. Wear self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Use personal protection recommended in Section 8, isolate the hazard area and deny entry to unnecessary and unprotected personnel.
Prevent further leakage or spillage if safe to do so. Do not allow product to enter sewer or waterways.
Absorb spill with inert material. Shovel material into appropriate container for disposal.
Materials: inert material
Related Products
Similar products with comparable safety profiles
BONDERITE M-NT 5200 MU AERO CONVERSION COATING
---
BONDERITE M-NT 1455 RTU CR FREE CONVERSION COATING
---
BONDERITE M-NT 8800 PART B CR FREE CONVERSION COATING AERO known as ALODINE® SG PART B
---
BONDERITE M-NT 1455T CONVERSION COATING
---
BONDERITE M-NT 5700 CR FREE CONVERSION COATING known as ALODINE 5700
---
BONDERITE M-NT 41042 CONVERSION COATING
---
BONDERITE M-NT 8453 CONVERSION COATING
---
BONDERITE M-NT 770X R N CONVERSION COATING
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Prevent contact with eyes, skin and clothing. Do not breathe vapor and mist. Wash thoroughly after handling. Do not take internally. For industrial use only.
Keep container tightly closed and in a cool, well-ventilated place away from incompatible materials. Protect from freezing.
Wash thoroughly after handling.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Ventilation should effectively remove and prevent buildup of any vapor/mist/fume/dust generated from the handling of this product.
Wear impervious gloves for prolonged contact.
Safety goggles or safety glasses with side shields.
If ventilation is not sufficient to effectively prevent buildup of aerosols, mists or vapors, appropriate NIOSH/MSHA respiratory protection must be provided.
Use of impervious apron and boots are recommended.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable at normal conditions.
Not available.
None under normal processing.
Keep away from heat, ignition sources and incompatible materials.
This product may react with strong acids, bases and oxidizing agents.
Upon decomposition, this product emits carbon monoxide, carbon dioxide and/or low molecular weight hydrocarbons.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is BONDERITE M-NT 5700 AERO CR FREE CONVERSION COATING known by?
BONDERITE M-NT 5700 AERO CR FREE CONVERSION COATING is also known as: ALODINE 5700
What is the hazard signal word for BONDERITE M-NT 5700 AERO CR FREE CONVERSION COATING?
The signal word is no signal word.
What is the physical form of BONDERITE M-NT 5700 AERO CR FREE CONVERSION COATING?
BONDERITE M-NT 5700 AERO CR FREE CONVERSION COATING is a liquid with yellow color. It has mild odor.
What is the solubility of BONDERITE M-NT 5700 AERO CR FREE CONVERSION COATING?
Complete
What is BONDERITE M-NT 5700 AERO CR FREE CONVERSION COATING used for?
Coating
What is the melting point of BONDERITE M-NT 5700 AERO CR FREE CONVERSION COATING?
The melting point is Not determined and the boiling point is > 100 °C (> 212°F).