NextSDS Logo
Safety Data Sheet EN

LOCTITE AA 3942 UV ACRYLIC ADHESIVE known as 3942 Light Cure Medical Device

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
LOCTITE AA 3942 UV ACRYLIC ADHESIVE known as 3942 Light Cure Medical Device
Product Code
36482

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Light curing

Uses advised against

None identified

Manufacturers & Suppliers

Henkel Corporation logo

Henkel Corporation

manufacturer

One Henkel Way, Rocky Hill, Connecticut 06067

+1 (860) 571-5100

www.henkelna.com

Emergency Contacts

Poison Control Center

1-877-671-4608

Poison Control Center

1-303-592-1711

CHEMTREC

1-800-424-9300

CHEMTREC

1-703-527-3887

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Flam. Liq. Cat. 4
Skin Irrit. Cat. 2
Eye Dam. Cat. 1
Skin Sens. Cat. 1
Repr. Cat. 2

GHS Pictograms

GHS05 - Corrosive

GHS05

GHS07 - Health hazard

GHS07

GHS08 - Serious health hazard

GHS08

Hazard Statements

H227 COMBUSTIBLE LIQUID.
H315 CAUSES SKIN IRRITATION.
H317 MAY CAUSE AN ALLERGIC SKIN REACTION.
H318 CAUSES SERIOUS EYE DAMAGE.
H361 SUSPECTED OF DAMAGING FERTILITY OR THE UNBORN CHILD.

Precautionary Statements

P201 Obtain special instructions before use.
P202 Do not handle until all safety precautions have been read and understood.
P210 Keep away from heat, sparks, open flames, hot surfaces - no smoking.
P261 Avoid breathing mist/vapours.
P264 Wash affected area thoroughly after handling.
P272 Contaminated work clothing should not be allowed out of the workplace.
P280 Wear protective gloves, clothing, eye and face protection.
P302 + P352 IF ON SKIN: Wash with plenty of water.
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P308 + P313 IF exposed or concerned: Get medical attention.
P333 + P313 If skin irritation or rash occurs: Get medical attention.
P362 + P364 Take off contaminated clothing and wash it before reuse.
P370 + P378 In case of fire: Use foam, dry chemical or carbon dioxide to extinguish.
P403 Store in a well-ventilated place.
P405 Store locked up.
P501 Dispose of contents and/or container according to Federal, State/Provincial and local governmental regulations.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Isobornyl acrylate 5888-33-5 30 - 60% No
2-Hydroxyethyl methacrylate 868-77-9 10 - 30% No
Isobornyl methacrylate 7534-94-3 5 - 10% No
Acrylic acid 79-10-7 1 - 5% No
Hydroxyalkyl methacrylate 27813-02-1 1 - 5% No
Gamma-glycidoxypropyl trimethoxysilane 2530-83-8 1 - 5% No
diphenyl(2,4,6-trimethylbenzoyl)phosphine oxide 75980-60-8 1 - 5% No
methacrylic acid 79-41-4 0.1 - 1% No
2-Propenoic acid, 2-methyl-, 2-(2-hydroxyethoxy)ethyl ester 2351-43-1 0.1 - 1% No

Notes

* Exact percentages may vary or are trade secret. Concentration range is provided to assist users in providing appropriate protections.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Get immediate medical attention.

Skin contact

Immediately flush skin with plenty of water (using soap, if available). Remove contaminated clothing and footwear. If symptoms develop and persist, get medical attention. Wash clothing before reuse.

Eye contact

Flush with copious amounts of water, preferably, lukewarm water for at least 15 minutes, holding eyelids open all the time. Get medical attention.

Ingestion

DO NOT induce vomiting unless directed to do so by medical personnel. Keep individual calm. Never give anything by mouth to an unconscious person. Get medical attention.

Immediate Medical Attention

Get immediate medical attention.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Foam, dry chemical or carbon dioxide.

Unsuitable media

Not available.

Specific hazards

Uncontrolled polymerization may occur at high temperatures resulting in explosions or rupture of storage containers.

Instructions

Water may be unsuitable as an extinguishing media, but may be helpful in keeping adjacent containers cool.

Firefighter Protection

Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

isolate the hazard area and deny entry to unnecessary and unprotected personnel.

Environmental

Do not allow product to enter sewer or waterways.

Cleanup methods

Soak up with inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust). Store in a partly filled, closed container until disposal.

Materials: sand, silica gel, acid binder, universal binder, sawdust

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Prevent contact with eyes, skin and clothing. Do not breathe vapor and mist. Do not taste or swallow.

Storage

Store at or below 38 °C. Keep in a cool, well ventilated area away from heat, sparks and open flame. Maintain head space in storage containers to support oxygen requirements of the inhibitor(s).

Hygiene

Wash thoroughly after handling.

Fire prevention

Keep away from heat, spark and flame.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
Transparent, Cloudy
Colour Intensity
---
Form
---
Odor
Sharp
Odor Threshold
Not available.
Ph
Not applicable
Melting Point
Not available.
Boiling Point
> 149 °C (> 300.2 °F)
Flash Point
70 °C (158°F) Pensky Martens closed cup
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not available.
Vapor Pressure
< 10 mm hg (24 °C (75.2 °F))
Vapor Density
---
Relative Density
1.1284
Bulk Density
---
Density
---
Flammability
Not applicable
Upper Explosive Limit
Not available.
Lower Explosive Limit
Not available.
Explosive Limits
---
Auto Ignition Temperature
Not available.
Decomposition Temperature
Not available.
Solubility
Slight Water
Partition Coefficient
Not available.
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
---
Voc Content
0.79 %; 8.91 g/l ASTM D5403 Process volatiles 0.32 %; 3.61 g/l (potential) 1.10 %; 12.41 g/l (total) (ASTM D5403)
Metal Corrosion
---
Dynamic Viscosity
Not available.
Kinematic Viscosity
Not available.
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions of storage and use.

Reactivity

Not available.

Hazardous reactions

May occur with excessive aging, excessive heat, polymerization catalyst, inhibitor depletion, direct sunlight and under oxygen-free atmospheres.

Avoid

Heat, flames, sparks and other sources of ignition. Ultraviolet radiation. Direct sunlight. Freezing conditions. Store away from incompatible materials. Loss of polymerization inhibitor. Loss of dissolved air.

Incompatible

Strong oxidizing agents. Strong reducing agents. Acids and bases. Free radical initiators. Peroxides. Heavy metals. Inert gases. Oxygen scavengers. Water. Humid air.

Decomposition

Oxides of carbon. Oxides of nitrogen. Oxides of silicon. Isocyanates. Hydrogen cyanide. Amines. Formaldehyde. Irritating organic vapours.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
UN3082
Shipping Name
Environmentally hazardous substance, liquid, n.o.s. (Isobornyl acrylate)
Transport Class
9
Packing Group
III
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for LOCTITE AA 3942 UV ACRYLIC ADHESIVE known as 3942 Light Cure Medical Device?

The signal word is danger.

What is the physical form of LOCTITE AA 3942 UV ACRYLIC ADHESIVE known as 3942 Light Cure Medical Device?

LOCTITE AA 3942 UV ACRYLIC ADHESIVE known as 3942 Light Cure Medical Device is a liquid with transparent, cloudy color. It has sharp odor.

What is the solubility of LOCTITE AA 3942 UV ACRYLIC ADHESIVE known as 3942 Light Cure Medical Device?

Slight Water

What is LOCTITE AA 3942 UV ACRYLIC ADHESIVE known as 3942 Light Cure Medical Device used for?

Light curing

What are the hazard statements for LOCTITE AA 3942 UV ACRYLIC ADHESIVE known as 3942 Light Cure Medical Device?

This substance has 5 hazard statements:

  • H227: COMBUSTIBLE LIQUID.
  • H315: CAUSES SKIN IRRITATION.
  • H317: MAY CAUSE AN ALLERGIC SKIN REACTION.
  • H318: CAUSES SERIOUS EYE DAMAGE.
  • H361: SUSPECTED OF DAMAGING FERTILITY OR THE UNBORN CHILD.

What is the melting point of LOCTITE AA 3942 UV ACRYLIC ADHESIVE known as 3942 Light Cure Medical Device?

The melting point is Not available. and the boiling point is > 149 °C (> 300.2 °F).