NextSDS Logo
Safety Data Sheet EN

BONDERITE S-AD 3305 ACHESON ACID INHIBITOR ADDITIVE

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
BONDERITE S-AD 3305 ACHESON ACID INHIBITOR ADDITIVE

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Additive

Uses advised against

None identified

Manufacturers & Suppliers

Henkel Corporation logo

Henkel Corporation

manufacturer

One Henkel Way, Rocky Hill, Connecticut 06067

+1 (860) 571-5100

http://www.henkelna.com

Emergency Contacts

Poison Control Center

1-877-671-4608

Poison Control Center

1-303-592-1711

CHEMTREC

1-800-424-9300

CHEMTREC

1-703-527-3887

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Skin Irrit. Cat. 2
Eye Irrit. Cat. 2A
Resp. Sens. Cat. 1
Skin Sens. Cat. 1

GHS Pictograms

GHS08 - Serious health hazard

GHS08

Hazard Statements

H315 CAUSES SKIN IRRITATION.
H317 MAY CAUSE AN ALLERGIC SKIN REACTION.
H319 CAUSES SERIOUS EYE IRRITATION.
H334 MAY CAUSE ALLERGY OR ASTHMA SYMPTOMS OR BREATHING DIFFICULTIES IF INHALED.

Precautionary Statements

P261 Avoid breathing mist/vapours.
P264 Wash affected area thoroughly after handling.
P272 Contaminated work clothing should not be allowed out of the workplace.
P280 Wear protective gloves, eye protection, and face protection.
P284 [In case of inadequate ventilation] wear respiratory protection.
P302 + P352 IF ON SKIN: Wash with plenty of water.
P304 + P340 IF INHALED: Remove person to fresh air and keep comfortable for breathing.
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P333 + P313 If skin irritation or rash occurs: Get medical attention.
P337 + P313 If eye irritation persists: Get medical attention.
P342 + P311 If experiencing respiratory symptoms: Call a poison center or physician.
P362 + P364 Take off contaminated clothing and wash it before reuse.
P501 Dispose of contents and/or container according to Federal, State/Provincial and local governmental regulations.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Hexamethylenetetramine hydrochloride 58713-21-6 10 - 30% Yes
Amines, polyethylenepoly-, benzyl chloride-quaternized, polymers with glyoxal 78330-33-3 1 - 5% Yes
methenamine 100-97-0 1 - 5% Yes
Coco alkyl amine with EO, acetates (salts) 61791-15-9 1 - 5% Yes
Tetraethylene pentamine 112-57-2 0.1 - 1% Yes
3,6,9,12-tetraazatetradecamethylenediamine 4067-16-7 0.1 - 1% Yes

Notes

* Exact percentages may vary or are trade secret. Concentration range is provided to assist users in providing appropriate protections.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

If symptoms are experienced, remove source of contamination or move victim to fresh air. If symptoms develop and persist, get medical attention.

Skin contact

For skin contact flush with large amounts of water. If symptoms develop and persist, get medical attention.

Eye contact

In case of contact with the eyes, rinse immediately with plenty of water for 15 minutes, and seek immediate medical attention.

Ingestion

Get immediate medical attention. Do not induce vomiting.

Immediate Medical Attention

Get immediate medical attention.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use media appropriate for surrounding material.

Unsuitable media

Not available.

Specific hazards

May liberate large quantities of dense, foul-smelling smoke which may contain unidentified toxic gasses.

Instructions

Wear self-contained breathing apparatus. Wear full protective clothing.

Firefighter Protection

Wear self-contained breathing apparatus. Wear full protective clothing.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Use personal protection recommended in Section 8, isolate the hazard area and deny entry to unnecessary and unprotected personnel.

Environmental

Ventilate area. Prevent further leakage or spillage if safe to do so. Wear appropriate protective equipment and clothing during clean-up. Do not allow product to enter sewer or waterways.

Cleanup methods

Absorb spill with inert material. Shovel material into appropriate container for disposal.

Materials: inert material

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid contact with eyes, skin and clothing. Provide adequate ventilation. Avoid breathing vapors or mists of this product. For industrial use only.

Storage

Keep container tightly closed and in a cool, well-ventilated place away from incompatible materials. Thaw and mix thoroughly if frozen.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
Brown
Colour Intensity
---
Form
---
Odor
Mild
Odor Threshold
Not available.
Ph
4.85 - 5.05
Melting Point
8 °F (-13.3 °C)
Boiling Point
> 100 °C (> 212°F)
Flash Point
> 93 °C (> 199.4 °F)
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not determined
Vapor Pressure
Not available.
Vapor Density
---
Relative Density
1.05 - 1.07 at 70 °F (21.11 °C)
Bulk Density
---
Density
---
Flammability
Not applicable
Upper Explosive Limit
Not applicable
Lower Explosive Limit
Not applicable
Explosive Limits
---
Auto Ignition Temperature
Not applicable
Decomposition Temperature
Not available.
Solubility
Complete Water
Partition Coefficient
Not determined
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
---
Voc Content
2.7 % EPA Method 24
Metal Corrosion
---
Dynamic Viscosity
Not available.
Kinematic Viscosity
Not available.
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable at normal conditions.

Reactivity

Not available.

Hazardous reactions

None under normal processing.

Avoid

Store away from incompatible materials.

Incompatible

This product may react with strong reducing agents. This product may react with strong oxidizing agents.

Decomposition

Upon decomposition, this product emits carbon monoxide, carbon dioxide and/or low molecular weight hydrocarbons.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for BONDERITE S-AD 3305 ACHESON ACID INHIBITOR ADDITIVE?

The signal word is danger.

What is the physical form of BONDERITE S-AD 3305 ACHESON ACID INHIBITOR ADDITIVE?

BONDERITE S-AD 3305 ACHESON ACID INHIBITOR ADDITIVE is a liquid with brown color. It has mild odor.

What is the solubility of BONDERITE S-AD 3305 ACHESON ACID INHIBITOR ADDITIVE?

Complete Water

What is BONDERITE S-AD 3305 ACHESON ACID INHIBITOR ADDITIVE used for?

Additive

What are the hazard statements for BONDERITE S-AD 3305 ACHESON ACID INHIBITOR ADDITIVE?

This substance has 4 hazard statements:

  • H315: CAUSES SKIN IRRITATION.
  • H317: MAY CAUSE AN ALLERGIC SKIN REACTION.
  • H319: CAUSES SERIOUS EYE IRRITATION.
  • H334: MAY CAUSE ALLERGY OR ASTHMA SYMPTOMS OR BREATHING DIFFICULTIES IF INHALED.

What is the melting point of BONDERITE S-AD 3305 ACHESON ACID INHIBITOR ADDITIVE?

The melting point is 8 °F (-13.3 °C) and the boiling point is > 100 °C (> 212°F).