Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
BITUMEN 100/40
Chemical Name
Asphalt oxidized

Regulatory Identifiers

CAS Number
N/A
REACH No.
01-2119498270-36-0056

Identified Uses

Mainly used for road paving, Miscellaneous industrial applications

Uses advised against

None unless specified elsewhere in this SDS.

Manufacturers & Suppliers

I

Iko sales International nv

Truibroek 74, 3945 Ham, Belgium

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance

No Hazardous Substance(s) required for disclosure.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Immediately remove from further exposure. Get immediate medical assistance. Give supplemental oxygen, if available. If breathing has stopped, assist ventilation with a mechanical device.

Skin contact

Wash contact areas with soap and water. If burned by contact with hot material, molten material adhering to skin should be cooled as quickly as possible with water, and see a physician for removal of adhering material and treatment of burn.

Eye contact

Flush thoroughly with water for at least 15 minutes. Get medical assistance.

Symptoms: Eye pain, redness, tearing, swelling of eyelids, itching.

Ingestion

First aid is normally not required. Seek medical attention if discomfort occurs.

Immediate Medical Attention

Get immediate medical assistance.

Medical Treatment

The need to have special means for providing specific and immediate medical treatment available in the workplace is not expected.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use dry chemical, carbon dioxide (CO2), or a dry, non-combustible material such as dry sand or earth to extinguish flames.

Unsuitable media

DO NOT USE WATER.

Instructions

Evacuate area. Prevent run-off from fire control or dilution from entering streams, sewers or drinking water supply. Use water spray to cool fire exposed surfaces and to protect personnel.

Firefighter Protection

Fire-fighters should use standard protective equipment and in enclosed spaces, self-contained breathing apparatus (SCBA).

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Small spill

normal work clothes are usually adequate

Large spill

full body suit of chemical and thermal resistant material is recommended

Environmental

Prevent entry into waterways, sewers, basements or confined areas.

Cleanup methods

Absorb or cover with dry earth, sand or other non-combustible material and transfer to containers.

Materials: dry earth, sand or other non-combustible material

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid vapour from heated materials to prevent exposure to potentially toxic/irritating fumes. Hydrogen sulphide (H2S) may be given off when this material is heated. Do not depend on sense of smell for warning. When heating to normal handling temperatures, avoid local overheating. Prevent small spills and leakage to avoid slip hazard.

Storage

Non-absorbent insulation such as foam glass is recommended for tankage and piping.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

The data for this section has not been processed yet.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Solid
Physical State Data
solid
State Under Standard Conditions
---
Appearance
---
Colour
Black
Colour Intensity
---
Form
---
Odor
Petroleum/Solvent
Odor Threshold
No data available
Ph
Not technically feasible
Melting Point
Not technically feasible
Boiling Point
> 400°C (752°F) [Estimated]
Flash Point
>220°C (428°F) [EN/ISO 2592]
Freezing Point
Not technically feasible
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not technically feasible
Vapor Pressure
< 0.013 kPa (0.1 mm Hg) at 20 °C [Estimated]
Vapor Density
> 1 at 101 kPa [Estimated]
Relative Density
1 - 1.1 [test method unavailable]
Bulk Density
---
Density
---
Flammability
[test method unavailable]
Upper Explosive Limit
5.0 [Estimated]
Lower Explosive Limit
0.5 [Estimated]
Explosive Limits
---
Auto Ignition Temperature
No data available
Decomposition Temperature
No data available
Solubility
---
Partition Coefficient
> 6 [Estimated]
Solubility In Water
Negligible
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
135 cSt (135 mm2/sec) at 135°C [test method unavailable]
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Material is stable under normal conditions.

Reactivity

See sub-sections below.

Hazardous reactions

Hazardous polymerization will not occur.

Avoid

Contact of hot product with water., Overheating.

Incompatible

Halogens, Alkalies, Strong Acids, Strong oxidisers

Decomposition

Material does not decompose at ambient temperatures.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
3257
Shipping Name
ELEVATED TEMPERATURE LIQUID, N.O.S. (Bitumen)
Transport Class
9
Packing Group
III
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for BITUMEN 100/40?

The signal word is no signal word.

What is the physical form of BITUMEN 100/40?

BITUMEN 100/40 is a solid with black color. It has petroleum/solvent odor.

What is BITUMEN 100/40 used for?

Mainly used for road paving, Miscellaneous industrial applications

What is the melting point of BITUMEN 100/40?

The melting point is Not technically feasible and the boiling point is > 400°C (752°F) [Estimated].