NextSDS Logo
Safety Data Sheet EN

FoamStop neutral

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
FoamStop neutral

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Defoamers, Anti-foaming agent

Uses advised against

No further relevant information available.

Manufacturers & Suppliers

Alfred Kärcher SE & Co. KG logo

Alfred Kärcher SE & Co. KG

manufacturer

Alfred-Kärcher-Str. 28-40, D - 71364 Winnenden

+49-7195-14-0

http://www.karcher.com

A

Alfred Kärcher SE & Co. KG (Department PCD-D)

manufacturer

+49-7195-14-2548

Emergency Contacts

CHEMTREC

1-800-424-9300

Day or Night

CHEMTREC

+1 703-741-5970

Day or Night

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

defoaming agent based on polysiloxanes

Chemical Name CAS Number Concentration Hazardous
Octadecan-1-ol, ethoxylated EC: 500-017-8 9005-00-9 1 - 2.5% Yes

Regulation (EC) No 648/2004 on detergents / Labelling for contents: perfumes. For the wording of the listed hazard phrases refer to section 16.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air; consult doctor in case of complaints.

Skin contact

Rinse with warm water.

Eye contact

Rinse opened eye for several minutes under running water.

Ingestion

Rinse out mouth and then drink plenty of water. If symptoms persist consult doctor.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

CO2, powder or water spray. Fight larger fires with water spray or alcohol resistant foam.

Unsuitable media

Water with full jet.

Specific hazards

No further relevant information available.

Firefighter Protection

No special measures required.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Not required.

Environmental

Do not allow to enter sewers/ surface or ground water. Do not allow to penetrate the ground/soil.

Cleanup methods

Absorb with liquid-binding material

Materials: sand, diatomite, acid binders, universal binders

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

No special measures required.

Storage

No special requirements.

Fire prevention

No special measures required.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. The exact break trough time has to be found out by the manufacturer of the protective gloves and has to be observed. For the permanent contact in work areas without heightened risk of injury (e.g. Laboratory) gloves made of the following material are suitable: butyl rubber 0,7 mm, 480 min. As protection from splashes gloves made of the following materials are suitable: nitril rubber 0,4 mm, 30 min (EN 374)

Eyes

Goggles recommended during refilling.

Respiratory

Not necessary if room is well-ventilated.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
Liquid
Colour
White
Colour Intensity
---
Form
Liquid
Odor
Specific type
Odor Threshold
Not determined.
Ph
Not determined.
Melting Point
0 °C
Boiling Point
100 °C
Flash Point
>100 °C
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not determined.
Vapor Pressure
23 hPa (at 20 °C)
Vapor Density
Not determined.
Relative Density
Not determined.
Bulk Density
---
Density
1.002 g/cm³ (at 20 °C)
Flammability
Not applicable.
Upper Explosive Limit
Not determined.
Lower Explosive Limit
Not determined.
Explosive Limits
---
Auto Ignition Temperature
Product is not selfigniting.
Decomposition Temperature
Not determined.
Solubility
---
Partition Coefficient
Not determined.
Solubility In Water
Not miscible or difficult to mix
Solubility In Fat
---
Molecular Weight
---
Voc Content
0.00 %
Metal Corrosion
---
Dynamic Viscosity
100 mPas (at 20 °C)
Kinematic Viscosity
Not determined.
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No decomposition if used according to specifications.

Reactivity

10.1 Reactivity corresponds to 10.3

Hazardous reactions

No dangerous reactions known

Avoid

No further relevant information available.

Incompatible

No further relevant information available.

Decomposition

No dangerous decomposition products known

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for FoamStop neutral?

The signal word is no signal word.

What is the physical form of FoamStop neutral?

FoamStop neutral is a liquid appearing as liquid with white color. It has specific type odor.

What is FoamStop neutral used for?

Defoamers, Anti-foaming agent

What is the melting point of FoamStop neutral?

The melting point is 0 °C and the boiling point is 100 °C.