NextSDS Logo
Safety Data Sheet EN

Liebherr Motoroil 5W-30

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Liebherr Motoroil 5W-30
Product Code
18032, 21032

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Engine oil

Uses advised against

No further relevant information available.

Manufacturers & Suppliers

L

LIEBHERR-LOGISTICS GmbH

manufacturer

St. Vitus 1, D - 88457 Kirchdorf an der Iller

+49 (0) 73 54 / 80-6060

L

LIEBHERR-COMPONENTS BIBERACH GmbH

manufacturer

Hans-Liebherr-Strasse 45, D - 88400 Biberach an der Riß

+49 (0) 73 54 / 80-6060

L

LIEBHERR-WERK BIBERACH GmbH

manufacturer

Memminger Straße 120, D - 88400 Biberach an der Riß

+49 (0) 73 54 / 80-6060

L

LIEBHERR-WERK EHINGEN GmbH

manufacturer

Dr.-Hans-Liebherr-Strasse 1, D - 89584 Ehingen

+49 (0) 73 54 / 80-6060

L

LIEBHERR-MISCHTECHNIK GmbH

manufacturer

Im Elchgrund 12, D - 88427 Bad Schussenried

+49 (0) 73 54 / 80-6060

L

LIEBHERR-MINING EQUIPMENT COLMAR SAS

manufacturer

49 rue Frédéric Hartmann, CS 50038, F - 68025 Colmar Cedex

+49 (0) 73 54 / 80-6060

L

LIEBHERR-WERK NENZING GmbH

manufacturer

Dr.-Hans-Liebherr-Strasse 1, A - 6710 Nenzing

+49 (0) 73 54 / 80-6060

L

Liebherr-Lubricants

Emergency Contacts

Emergency Contact

+ 49 (0) 73 54 / 80-6060

During working hours (CET)

CHEMTREC

+1-703-527-3887

24 hours

Emergency Contact

+44-870-8200418

Emergency Contact

+(61)-290372994

Emergency Contact

+31-858880596

Emergency Contact

0-800-983-611

Emergency Contact

1-800-424-9300

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Precautionary Statements

P501 Dispose of contents/container in accordance with local regulations.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Mineral oil, viscosity <20.5 mm²/s at 40 °C --- 50 - 100% Yes
Zinc bis[O-(6-methylheptyl)] bis[O-(sec-butyl)] bis(dithiophosphate) EC: 298-577-9 93819-94-4 0.25 - 2.5% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air.

Skin contact

Immediately wash with water and soap and rinse thoroughly.

Eye contact

Rinse opened eye for several minutes under running water. If symptoms persist, consult a doctor.

Ingestion

Do not induce vomiting; call for medical help immediately.

Immediate Medical Attention

call for medical help immediately

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

CO2, sand, extinguishing powder. Use fire extinguishing methods suitable to surrounding conditions.

Unsuitable media

Do not use water with full jet.

Specific hazards

Formation of harmful gases is possible in case fo fire.

Firefighter Protection

Wear self-contained respiratory protective device. Wear fully protective suit.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Particular danger of slipping on leaked/spilled product.

Environmental

Do not allow to enter sewers, surface or ground water. Prevent from spreading (e.g. by damming-in or oil barriers).

Cleanup methods

Absorb with liquid-binding material (sand, diatomite, acid binders, universal binders, sawdust).

Materials: sand, diatomite, acid binders, universal binders, sawdust

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

When handling product in drums use safety footwear and suitable tools. At work please do not eat, drink or smoke.

Storage

Store in cool, dry place in tightly closed receptacles.

Hygiene

At work please do not eat, drink or smoke.

Fire prevention

Fire class DIN EN 2: B

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Safety gloves of nitrile rubber or viton. Preventive skin protection by use of skin-protecting agents is recommended. Material of gloves: Fluorocarbon rubber (Viton), Nitrile rubber, NBR. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. Penetration time of glove material: The exact break trough time has to be found out by the manufacturer of the protective gloves and has to be observed. Value for the permeation: Level = 6 (480 min)

Eyes

Goggles recommended during refilling.

Respiratory

No respiratory protection is ordinarily required under normal conditions of use. Select a filter suitable for combined particulate/ gases and organic vapours (boiling point > 65 °C, AP2, EN 14387), if exposure limit is exceeded or when aerosol or mist is formed.

Skin/Body

Protective work clothing.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
Amber coloured
Colour
Amber coloured
Colour Intensity
---
Form
Fluid
Odor
Mild
Odor Threshold
Not determined.
Ph
Not determined.
Melting Point
Not determined.
Boiling Point
Not determined.
Flash Point
>200 °C (DIN EN ISO 2592)
Freezing Point
Not determined.
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not determined.
Vapor Pressure
Not determined.
Vapor Density
Not determined.
Relative Density
Not determined.
Bulk Density
---
Density
0.855 g/cm³ (DIN 51 757)
Flammability
Not applicable.
Upper Explosive Limit
10 Vol % (typ.)
Lower Explosive Limit
1.0 Vol % (typ.)
Explosive Limits
---
Auto Ignition Temperature
> 320 °C
Decomposition Temperature
Not determined.
Solubility
---
Partition Coefficient
> 6
Solubility In Water
Not miscible or difficult to mix.
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
72 mm²/s (DIN 51 562)
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable at normal conditions.

Reactivity

See 10.2 to 10.6

Hazardous reactions

Reacts with strong oxidising agents.

Avoid

Avoid contact with heat, sparks, flames and all other sources of ignition.

Incompatible

No further relevant information available.

Decomposition

No dangerous decomposition products known.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Liebherr Motoroil 5W-30?

The signal word is no signal word.

What is the physical form of Liebherr Motoroil 5W-30?

Liebherr Motoroil 5W-30 is a liquid appearing as amber coloured with amber coloured color. It has mild odor.

What is Liebherr Motoroil 5W-30 used for?

Engine oil

What is the melting point of Liebherr Motoroil 5W-30?

The melting point is Not determined. and the boiling point is Not determined..