Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- WALL FIX A
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Construction: mortar Epoxy resin
Uses advised against
No uses advised against known
Manufacturers & Suppliers
TEC7
distributor
Industrielaan 5B, B-2250 Olen
+32 14 85 97 37
Novatech International N.V.
manufacturer
Industrielaan 5B, B-2250 Olen
+32 14 85 97 37
Emergency Contacts
BIG
+32 14 58 45 45
24h/24h
EN, FR, DE, NL
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
GHS09
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| bis-[4-(2,3-epoxipropoxi)phenyl]propane EC: 216-823-5 | 1675-54-3 | 5 - 15% | Yes |
| reaction mass of 2,2'-[methylenebis(2,1-phenyleneoxymethylene)]bis(oxirane) and 2,2'-[methylenebis(4,1-phenyleneoxymethylene)]bis(oxirane) and 2-((2-(4-(oxiran-2-ylmethoxy)benzyl) phenoxy)methyl)oxirane | 9003-36-5 | 5 - 15% | Yes |
| terpineol EC: 232-268-1 | 8000-41-7 | 5% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove victim into fresh air. In case of respiratory problems, consult a doctor/medical service.
Symptoms: No effects known.
If possible, wipe up/dry remove chemical. Then rinse/shower immediately with (lukewarm) water. If irritation persists, consult a doctor/medical service.
Symptoms: Tingling/irritation of the skin.
Rinse immediately with plenty of water. Remove contact lenses, if present and easy to do. Continue rinsing. If irritation persists, consult a doctor/medical service.
Symptoms: Irritation of the eye tissue. Redness of the eye tissue. Lacrimation.
Rinse mouth with water. If you feel unwell, consult a doctor/medical service. Do not wait for symptoms to occur to consult Poison Center.
Symptoms: Gastrointestinal complaints.
Immediate Medical Attention
In case of injury and/or intoxication, call the European emergency number 112.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Small fire: Quick-acting ABC powder extinguisher, Class A foam extinguisher, Water (quick-acting extinguisher, reel). Major fire: Water, Class A foam.
Small fire: Quick-acting BC powder extinguisher, Quick-acting CO2 extinguisher.
On burning: release of toxic and corrosive gases/vapours e.g. hydrogen chloride, carbon monoxide - carbon dioxide. May polymerize on exposure to temperature rise.
Dilute toxic gases with water spray. Take account of toxic/corrosive precipitation water. Take account of environmentally hazardous firefighting water. Use water moderately and if possible collect or contain it.
Firefighter Protection
Gloves (EN 374). Face shield (EN 166). Protective clothing (EN 14605 or EN 13034). Heat/fire exposure: self-contained breathing apparatus (EN 136 + EN 137).
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Contain released product. Dam up the solid spill. Prevent soil and water pollution. Prevent spreading in sewers.
Scoop solid spill into closing containers. Carefully collect the spill/leftovers. Clean contaminated surfaces with an excess of water.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Keep away from naked flames/heat. Observe very strict hygiene - avoid contact. Remove contaminated clothing immediately. Keep container tightly closed.
Keep container tightly closed.
Observe very strict hygiene - avoid contact. Remove contaminated clothing immediately.
Keep away from naked flames/heat.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Keep away from naked flames/heat. Carry operations in the open/under local exhaust/ventilation or with respiratory protection.
Protective gloves against chemicals (EN 374). Materials: nitrile rubber, Measured breakthrough time: >480 minutes, Thickness: 0.35 mm, Protection index: Class 6
Safety glasses (EN 166).
Insufficient ventilation: wear respiratory protection.
Protective clothing (EN 14605 or EN 13034).
See sections 6.2, 6.3 and 13
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
Temperature above flashpoint: higher fire/explosion hazard.
No data available.
Keep away from naked flames/heat.
Oxidizing agents, (strong) bases, reducing agents, (strong) acids.
On burning: release of toxic and corrosive gases/vapours e.g. hydrogen chloride, carbon monoxide - carbon dioxide.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 3077
- Shipping Name
- environmentally hazardous substance, solid, n.o.s. (bis-[4-(2,3-epoxipropoxi)phenyl]propane)
- Transport Class
- 9
- Packing Group
- III
274, 335, 966, 967, 969
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for WALL FIX A?
The signal word is warning.
What is the physical form of WALL FIX A?
WALL FIX A is a solid with grey-green color. It has characteristic odour odor.
What is the solubility of WALL FIX A?
Water ; insoluble
What is WALL FIX A used for?
Construction: mortar Epoxy resin
What are the hazard statements for WALL FIX A?
This substance has 4 hazard statements:
- H315: Causes skin irritation.
- H317: May cause an allergic skin reaction.
- H319: Causes serious eye irritation.
- H411: Toxic to aquatic life with long lasting effects.
What is the melting point of WALL FIX A?
The melting point is No data available in the literature and the boiling point is > 200 °C.