Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- ZEP FOAMING COIL CLEANER AERO DZ
- Product Code
- 000000000000020201
Regulatory Identifiers
- CAS Number
- N/A
Manufacturers & Suppliers
Zep Inc.
manufacturer
1310 Seaboard Industrial Blvd., NW Atlanta, GA 30318
404-352-1680
Emergency Contacts
Emergency Contact
877-541-2016
CHEMTREC
800-424-9300
Emergency Contact
202-483-7616
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS04
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| 1-(1-methyl-2-propoxyethoxy)propan-2-ol | 29911-27-1 | 1 - 5% | Yes |
| butane | 106-97-8 | 1 - 5% | Yes |
| propane-1,2-diol | 57-55-6 | 1 - 5% | Yes |
| propane | 74-98-6 | 1 - 5% | Yes |
| sodium nitrite | 7632-00-0 | 0.1 - 1% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
If unconscious place in recovery position and seek medical advice. If symptoms persist, call a physician.
Wash off immediately with plenty of water for at least 15 minutes.
Remove contact lenses. Rinse immediately with plenty of water for at least 15 minutes. Keep eye wide open while rinsing.
Keep respiratory tract clear. Never give anything by mouth to an unconscious person. DO NOT induce vomiting unless directed to do so by a physician or poison control center.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Alcohol-resistant foam, Carbon dioxide (CO2), Dry chemical
High volume water jet
Do not allow run-off from fire fighting to enter drains or water courses.
Use extinguishing measures that are appropriate to local circumstances and the surrounding environment. Standard procedure for chemical fires.
Firefighter Protection
Wear self-contained breathing apparatus for firefighting if necessary.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Use personal protective equipment. Ensure adequate ventilation. Remove all sources of ignition.
Prevent further leakage or spillage if safe to do so.
Sweep up or vacuum up spillage and collect in suitable container for disposal.
Materials: inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust)
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Smoking, eating and drinking should be prohibited in the application area.
BEWARE: Aerosol is pressurized. Keep away from direct sun exposure and temperatures over 50 °C. Do not open by force or throw into fire even after use. Do not spray on flames or red-hot objects. Keep container tightly closed in a dry and well-ventilated place.
Smoking, eating and drinking should be prohibited in the application area.
Do not spray on flames or red-hot objects.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
Stable
Vapours may form explosive mixture with air. No decomposition if stored and applied as directed.
Heat, flames and sparks.
Oxidizing agents Acids
Carbon oxides Organic Substances
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1950
- Shipping Name
- Aerosols, non-flammable
- Transport Class
- 2.2
- Packing Group
- Not Assigned
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for ZEP FOAMING COIL CLEANER AERO DZ?
The signal word is warning.
What is the physical form of ZEP FOAMING COIL CLEANER AERO DZ?
ZEP FOAMING COIL CLEANER AERO DZ is a aerosol containing a liquefied gas appearing as aerosol containing a liquefied gas with colourless, clear color. It has characteristic odor.
What are the hazard statements for ZEP FOAMING COIL CLEANER AERO DZ?
This substance has 1 hazard statement:
- H280: Contains gas under pressure; may explode if heated.
What is the melting point of ZEP FOAMING COIL CLEANER AERO DZ?
The melting point is not applicable and the boiling point is 100 °C.