Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- FlexPak & Flex Thin Plate Pure Lead
- Synonyms
- Sealed Lead Acid Battery, TPPL Battery
Regulatory Identifiers
- CAS Number
- N/A
Manufacturers & Suppliers
Hawker Powersource, Inc.
manufacturer
PO Box 808, Ooltewah, TN 37363-0808
423-238-0361
Canada Corporate Office
manufacturer
3-61 Parr Boulevard, Bolton, Ontario L7E 4E3
Emergency Contacts
Hawker Powersource Environmental, Health & Safety Dept.
423-238-0361
CHEMTREC
800-424-9300
CHEMTREC
703-527-3877
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS01
GHS05
GHS07
GHS08
GHS09
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Inorganic lead and sulfuric acid electrolyte are the primary components of every battery manufactured by Hawker Powersource, Inc.There are no mercury or cadmium containing products present in batteries manufactured by Hawker Powersource, Inc.
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Lead | 7439-92-1 | 45 - 60% | No |
| Lead Dioxide | 1309-60-0 | 15 - 25% | No |
| Tin | 7440-31-5 | 0.1 - 0.2% | No |
| Sulfuric Acid Electrolyte (Sulfuric Acid/Water) | 7664-93-9 | 15 - 20% | No |
| Case Material | --- | 5 - 10% | No |
| Polypropylene | 9003-07-0 | --- | No |
| Polystyrene | 9003-53-6 | --- | No |
| Styrene Acrylonitrile | 9003-54-7 | --- | No |
| Acrylonitrile Butadiene Styrene | 9003-56-9 | --- | No |
| Styrene Butadiene | 9003-55-8 | --- | No |
| Polyvinylchloride | 9002-86-2 | --- | No |
| Polycarbonate, Hard Rubber, Polyethylene | 9002-88-4 | --- | No |
| Polyphenylene Oxide | 25134-01-4 | --- | No |
| Polycarbonate/Polyester Alloy | --- | --- | No |
| Other: Absorbent Glass Mat | --- | 1 - 2% | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
Sulfuric Acid: Remove to fresh air immediately. If breathing is difficult, give oxygen. Consult a physician. Lead: Remove from exposure, gargle, wash nose and lips; consult physician.
Sulfuric Acid: Flush with large amounts of water for at least 15 minutes; remove contaminated clothing completely, including shoes. If symptoms persist, seek medical attention. Wash contaminated clothing before reuse. Discard contaminated shoes. Lead: Wash immediately with soap and water.
Sulfuric Acid and Lead: Flush immediately with large amounts of water for at least 15 minutes while lifting lids. Seek immediate medical attention if eyes have been exposed directly to acid.
Sulfuric Acid: Give large quantities of water; do not induce vomiting or aspiration into the lungs may occur and can cause permanent injury or death; consult a physician. Lead: Consult physician immediately.
Immediate Medical Attention
Consult a physician (Sulfuric Acid/Lead). Seek immediate medical attention if eyes have been exposed directly to acid.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Carbon dioxide; foam; dry chemical. Use appropriate media for surrounding fire.
Highly flammable hydrogen gas is generated during charging and operation of batteries. To avoid risk of fire or explosion, keep sparks or other sources of ignition away from batteries. Do not allow metallic materials to simultaneously contact negative and positive terminals of cells and batteries. Follow manufacturer's instructions for installation and service.
If batteries are on charge, shut off power. Note that strings of series connected batteries may still pose risk of electric shock even when charging equipment is shut down.
Firefighter Protection
Use positive pressure, self-contained breathing apparatus. Wear acid-resistant clothing, gloves, face and eye protection.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Stop flow of material, contain/absorb small spills with dry sand, earth, and vermiculite. Do not use combustible materials. If possible, carefully neutralize spilled electrolyte with soda ash, sodium bicarbonate, lime, etc.
contain/absorb small spills with dry sand, earth, and vermiculite
Acid must be managed in accordance with local, state, and federal requirements.
contain/absorb small spills with dry sand, earth, and vermiculite. Do not use combustible materials. If possible, carefully neutralize spilled electrolyte with soda ash, sodium bicarbonate, lime, etc.
Materials: dry sand, earth, and vermiculite, soda ash, sodium bicarbonate, lime
Related Products
Similar products with comparable safety profiles
Selemix Direct binder GL 80% Leadfree Variable Pack Size
---
Lead plate
CAS: 7439-92-1
SUPA-FLEX
---
Pluriol® E 400 LS-FLEX
CAS: 25322-68-3
Products Containing FLEX Antibody Diluent
---
K-FLEX K-425
---
Lead foil for analysis about 0.25 mm thick EMSURE®
CAS: 7439-92-1
CLEARFIL AP-X, CLEARFIL AP-X PLT
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Unless involved in recycling operations, do not breach the casing or empty the contents of the battery. There may be increasing risk of electric shock from strings of connected batteries. Keep containers tightly closed when not in use. If battery case is broken, avoid contact with internal components. Keep vent caps on and cover terminals to prevent short circuits. Place cardboard between layers of stacked automotive batteries to avoid damage and short circuits. Keep away from combustible materials, organic chemicals, reducing substances, metals, strong oxidizers and water. Use banding or stretch wrap to secure items for shipping.
Store batteries in cool, dry, well-ventilated areas with impervious surfaces and adequate containment in the event of spills. Batteries should also be stored under roof for protection against adverse weather conditions.
Wear face and eye protection when near batteries being charged.
Keep away from fire, sparks and heat. Prohibit smoking and avoid creation of flames and sparks nearby.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
This product is stable under normal conditions at ambient temperature
Will not occur
Prolonged overcharge; sources of ignition
Sulfuric Acid: Contact with combustibles and organic materials may cause fire and explosion. Also reacts violently with strong reducing agents, metals, sulfur trioxide gas, strong oxidizers and water. Contact with metals may produce toxic sulfur dioxide fumes and may release flammable hydrogen gas. Lead Compounds: Avoid contact with strong acids, bases, halides, halogenates, potassium nitrate, permanganate, peroxides, nascent hydrogen and reducing agents.
Sulfuric Acid: Sulfur trioxide, carbon monoxide, sulfuric acid mist, sulfur dioxide, and hydrogen sulfide. Lead Compounds: High temperatures likely to produce toxic metal fume, vapor, or dust; contact with strong acid or base or presence of nascent hydrogen may generate highly toxic arsine gas.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN2800
- Shipping Name
- BATTERIES, WET, NON-SPILLABLE
- Transport Class
- 8
Battery terminals must be protected against short circuits.
Battery Terminals must be protected against short circuits. The words " NOT RESTRICTED" , SPECIAL PROVISION A67" must be provided when the air waybill is issued.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is FlexPak & Flex Thin Plate Pure Lead known by?
FlexPak & Flex Thin Plate Pure Lead is also known as: Sealed Lead Acid Battery, TPPL Battery
What is the hazard signal word for FlexPak & Flex Thin Plate Pure Lead?
The signal word is danger.
What is the physical form of FlexPak & Flex Thin Plate Pure Lead?
FlexPak & Flex Thin Plate Pure Lead is a liquid appearing as manufactured article; no apparent odor. electrolyte is a clear liquid with a sharp, penetrating, pungent odor. . It has sharp, penetrating, pungent odor odor.
What are the hazard statements for FlexPak & Flex Thin Plate Pure Lead?
This substance has 9 hazard statements:
- H203: Explosive, fire, blast, or projection hazard.
- H242: May form explosive air/gas mixture during charging.
- H302 + H312 + H332: Harmful if swallowed, inhaled, or contact with skin
- H314: Causes severe skin burns and serious eye damage.
- H318: Causes skin irritation, serious eye damage.
- H350: May cause cancer if ingested or inhaled.
- H360: May damage fertility or the unborn child if ingested or inhaled.
- H362: May cause harm to breast-fed children
- H372: Causes damage to central nervous system, blood and kidneys through prolonged or repeated exposure.