Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- LD-90
- Product Form
- Aerosol
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Gas leak detector
Manufacturers & Suppliers
CRC Industries UK Ltd.
manufacturer
Wylds Road, Castlefield Industrial Estate, TA6 4DD Bridgwater Somerset, United Kingdom
+44 1278 727200
Emergency Contacts
Emergency Contact
(+44)(0)1278 72 7200
office hours
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| 2-amino-2-methylpropanol EC: 204-709-8 | 124-68-5 | 1% | Yes |
| dinitrogen oxide EC: 233-032-0 | 10024-97-2 | 2.5% | Yes |
| (Z)-N-methyl-N-(1-oxo-9-octadecenyl)glycine EC: 203-749-3 | 110-25-8 | 2.5% | Yes |
| Amines, C12-14 (even numbered)-alkyldimethyl, N-oxides EC: 931-292-6 | 308062-28-4 | 0.25% | Yes |
| Oxazolidine, 4,4-dimethyl- EC: 257-048-2 | 51200-87-4 | 0.1% | Yes |
| 1-Butanol, 2-amino- EC: 202-488-2 | 96-20-8 | 0.1% | Yes |
| 1,2-benzisothiazol-3(2H)-one EC: 220-120-9 | 2634-33-5 | 0.005% | Yes |
| 2-methyl-2H-isothiazol-3-one EC: 220-239-6 | 2682-20-4 | 0.0015 - 0.005% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
IF INHALED: Remove person to fresh air and keep comfortable for breathing. Call a POISON CENTER or doctor/physician if you feel unwell.
Symptoms: No harmful effects known if used for its intended purpose
Take off contaminated clothing and wash before reuse. IF ON SKIN: Rinse cautiously with water for several minutes. If skin irritation occurs: Get medical advice/attention.
Symptoms: May cause an allergic skin reaction. Symptoms : redness and pain
IF IN EYES: Rinse cautiously with water for several minutes. If eye irritation persists: Get medical advice/attention.
Symptoms: Causes serious eye irritation. Symptoms : redness and pain
Seek medical attention if ill effects occur
Symptoms: May cause gastrointestinal disturbances
Immediate Medical Attention
If skin or eye irritation occurs: Get medical advice/attention.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
foam, carbon dioxide or dry agent
Aerosols may explode if heated above 50°C
Keep container(s) exposed to fire cool, by spraying with water
Firefighter Protection
In case of fire, do not breathe fumes
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Do not allow to enter public sewers and watercourses
Absorb spillage in suitable inert material
Materials: suitable inert material
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Do not pierce or burn aerosols, even after use. Do not breathe aerosols or vapours. Avoid contact with skin and eyes. Wear protective gloves/protective clothing/eye protection/face protection.
Pressurized container : protect from sunlight and do not expose to temperatures exceeding 50°C. Keep out of reach of children.
Wash thoroughly after use
Keep away from heat and sources of ignition. Do not spray on a naked flame or incandescent material.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Ensure adequate ventilation Keep away from heat and sources of ignition
When handling the product wear chemical-resistant gloves (standard EN 374). Use a reusable glove with a minimum breakthrough time of 30 minutes. The breakthrough time of the glove should be longer than the total duration of product use. If work lasts longer than the breakthrough time, gloves should be changed part-way through. Nitrile recommended breakthrough time > 480 minutes. Recommended thickness < 0.45 mm
Wear safety eyewear according to EN 166.
In case of insufficient ventilation, wear suitable respiratory equipment. Air purifying respirator equipped with organic gas/vapor cartridge (type A)
When handling the product wear chemical-resistant gloves (standard EN 374).
Avoid release to the environment. Collect spillage.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable
No hazardous reactions known if used for its intended purpose
No hazardous reactions known if used for its intended purpose
Avoid overheating
Strong oxidising agent
CO,CO2
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1950
- Shipping Name
- AEROSOLS
- Transport Class
- 2.2
- Packing Group
- Not applicable.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for LD-90?
The signal word is warning.
What is the physical form of LD-90?
LD-90 is a n2o propelled liquid. appearing as n2o propelled liquid. with colorless. color. It has neutral. odor.
What is LD-90 used for?
Gas leak detector
What are the hazard statements for LD-90?
This substance has 3 hazard statements:
- H229: Pressurised container: May burst if heated.
- H317: May cause an allergic skin reaction.
- H319: Causes serious eye irritation.