Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Formaldehyde 35 % TECHNICAL stabilized with 10-15 % of methanol
- Product Code
- 90240
Regulatory Identifiers
- CAS Number
- 50-00-0 Check regulations →
Identified Uses
General chemical reagent
Manufacturers & Suppliers
VWR International Ltd.
distributor
Hunter Boulevard, Magna Park, Lutterworth, LE17 4XN
0800 22 33 44
Emergency Contacts
CareChem24
+44 (0) 1270 502894
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS05
GHS06
GHS08
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
First Aid Measures
Emergency procedures for chemical exposure incidents
Immediately call a POISON CENTRE/doctor. Remove casualty to fresh air and keep warm and at rest. If breathing is irregular or stopped, administer artificial respiration.
After contact with skin, wash immediately with plenty of water and soap. Remove contaminated, saturated clothing immediately. Immediate medical treatment required because corrosive injuries that are not treated are hard to cure.
In case of contact with eyes flush immediately with plenty of flowing water for 10 to 15 minutes holding eyelids apart and consult an ophthalmologist. Protect uninjured eye. Remove contact lenses, if present and easy to do. Continue rinsing.
Immediately call a POISON CENTRE/doctor. Do NOT induce vomiting. Rinse mouth thoroughly with water. Give nothing to eat or drink.
Immediate Medical Attention
Immediate medical treatment required because corrosive injuries that are not treated are hard to cure.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
The product itself does not burn. Co-ordinate fire-fighting measures to the fire surroundings.
no restriction
In case of fire may be liberated: Carbon monoxide, Carbon dioxide (CO2)
Use water spray jet to protect personnel and to cool endangered containers.
Firefighter Protection
Wear a self-contained breathing apparatus and chemical protective clothing.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Do not breathe gas/vapour/aerosol. Provide adequate ventilation. Use personal protection equipment. In case of major fire and large quantities: Remove persons to safety.
In case of major fire and large quantities: Remove persons to safety. Wear a self-contained breathing apparatus and chemical protective clothing.
Do not allow to enter into surface water or drains. Make sure spills can be contained, e.g. in sump pallets or kerbed areas. Discharge into the environment must be avoided.
Clean contaminated articles and floor according to the environmental legislation.
Related Products
Similar products with comparable safety profiles
Formaldehyde solution about 37% stabilized with about 10% methanol Ph Eur,BP,USP
---
Formaldehyde in Methanol
---
Formaldehyde solution 37-41%
UFI: F5US-FQ5M-VS2M-YVU4
Formaldehyde 37% solution
CAS: Mixture.
Formaldehyde solution min. 37% free from acid stabilized with about 10% methanol and calcium carbonate for histology
---
Formaldehyde 37% Solution
---
Formaldehyde, 37% w/w in aqueous solution
UFI: 3YU0-N349-FX0C-MHMQ
Formaldehyde solution
CAS: 50-00-0
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid inhalation. Avoid contact with eyes and skin. Protect from moisture.
Keep container tightly closed and in a well-ventilated place.
Wash hands before breaks and after work. When using do not eat, drink or smoke.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Technical measures and the application of suitable work processes have priority over personal protection equipment. If handled uncovered, arrangements with local exhaust ventilation have to be used.
When handling with chemical substances, protective gloves must be worn with the CE-label including the four control digits. Recommended glove articles DIN-/EN-Norms EN ISO 374 In the case of wanting to use the gloves again, clean them before taking off and air them well. By short-term hand contact Suitable material: NBR (Nitrile rubber) Thickness of the glove material: 0,12 mm Breakthrough time:: 240-480 min Recommended glove articles: VWR 112-0998 By long-term hand contact Suitable material: NBR (Nitrile rubber) Thickness of the glove material: 0,38 mm Breakthrough time:: Recommended glove articles: VWR 112-3717 / 112-1381
Eye glasses with side protection DIN-/EN-Norms DIN EN 166 Recommendation: VWR 111-0432
Respiratory protection necessary at: aerosol or mist formation Suitable respiratory protection apparatus: Full-/half-/quarter-face masks (DIN EN 136/140) Recommendation: VWR 111-0206 Suitable material: A1 Recommendation: VWR 111-8930
Wear suitable protective clothing. When handling with chemical substances, protective clothing with CE-labels including the four control digits must be worn.
no data available
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is chemically stable under standard ambient conditions (room temperature).
Vapours can form explosive mixtures with air.
Formation of explosive mixtures with: Oxidising agent, Nitrogen oxides (NOx), Material, oxygen-rich, Oxidising, Nitric acid, Chlorine, Bromine. Exothermic reaction with: Reducing agent, Acid, Acid halides, Alkali (lye), concentrated. Violent reaction with: Alkali metals, Alkaline earth metal. Formation of: Hydrogen.
UV-radiation/sunlight, Heat. This material is combustible and can be ignited by heat, sparks, flames, or other sources of ignition (e.g. static electricity, pilot lights, or mechanical/electrical equipment).
light metals, Plastic articles
no data available
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 2209
- Shipping Name
- FORMALDEHYDE SOLUTION
- Transport Class
- 8
- Packing Group
- III
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Formaldehyde 35 % TECHNICAL stabilized with 10-15 % of methanol?
The signal word is danger.
What is the physical form of Formaldehyde 35 % TECHNICAL stabilized with 10-15 % of methanol?
Formaldehyde 35 % TECHNICAL stabilized with 10-15 % of methanol is a liquid appearing as liquid, colourless with colourless color. It has pungent odor.
What is Formaldehyde 35 % TECHNICAL stabilized with 10-15 % of methanol used for?
General chemical reagent
What are the hazard statements for Formaldehyde 35 % TECHNICAL stabilized with 10-15 % of methanol?
This substance has 7 hazard statements:
- H301 + H311 + H331: Toxic if swallowed, in contact with skin or if inhaled.
- H314: Causes severe skin burns and eye damage.
- H317: May cause an allergic skin reaction.
- H335: May cause respiratory irritation.
- H341: Suspected of causing genetic defects.
- H350: May cause cancer.
- H370: Causes damage to organs.
What is the melting point of Formaldehyde 35 % TECHNICAL stabilized with 10-15 % of methanol?