Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Acute Tox. Cat. 4 H302
Repr. Cat. 1B H360FD
STOT RE Cat. 2 H373

GHS Pictograms

GHS07 - Health hazard

GHS07

GHS08 - Serious health hazard

GHS08

Hazard Statements

H302 Harmful if swallowed.
H360FD May damage fertility. May damage the unborn child.
H373 May cause damage to organs (Immune system) through prolonged or repeated exposure.

Precautionary Statements

P202 Do not handle until all safety precautions have been read and understood.
P260 Do not breathe mist or vapours.
P264 Wash skin thoroughly after handling.
P280 Wear protective gloves/ protective clothing/ eye protection/ face protection.
P301 + P312 IF SWALLOWED: Call a POISON CENTER/ doctor if you feel unwell.
P308 + P313 IF exposed or concerned: Get medical advice/ attention.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
sulpholane; tetrahydrothiophene 1,1-dioxide EC: 204-783-1 126-33-0 90 - 100% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

After inhalation: fresh air. Call in physician.

Skin contact

In case of skin contact: Take off immediately all contaminated clothing. Rinse skin with water/ shower. Consult a physician.

Eye contact

After eye contact: rinse out with plenty of water. Call in ophthalmologist. Remove contact lenses.

Ingestion

After swallowing: immediately make victim drink water (two glasses at most). Consult a physician.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water, Foam, Carbon dioxide (CO2), Dry powder

Unsuitable media

For this substance/mixture no limitations of extinguishing agents are given.

Specific hazards

Combustible. Vapours are heavier than air and may spread along floors. Forms explosive mixtures with air on intense heating. Development of hazardous combustion gases or vapours possible in the event of fire.

Instructions

Suppress (knock down) gases/vapours/mists with a water spray jet.

Firefighter Protection

Stay in danger area only with self-contained breathing apparatus. Prevent skin contact by keeping a safe distance or by wearing suitable protective clothing.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Evacuate the danger area, observe emergency procedures, consult an expert.

Environmental

Do not let product enter drains.

Cleanup methods

Cover drains. Collect, bind, and pump off spills. Observe possible material restrictions (see sections 7 and 10). Take up carefully with liquid-absorbent material (e.g. Chemizorb®). Dispose of properly. Clean up affected area.

Materials: liquid-absorbent material (e.g. Chemizorb®)

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Work under hood. Do not inhale substance/mixture. Avoid generation of vapours/aerosols.

Storage

Tightly closed. Keep in a well-ventilated place. Keep locked up or in an area accessible only to qualified or authorised persons.

Hygiene

Immediately change contaminated clothing. Apply preventive skin protection. Wash hands and face after working with substance.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Material : Chloroprene, Break through time : 480 min, Glove thickness : 0,65 mm, Protective index : Full contact, Manufacturer : KCL 720 Camapren®; Material : Latex gloves, Break through time : 30 min, Glove thickness : 0,6 mm, Protective index : Splash contact, Manufacturer : Lapren® (KCL 706 / Aldrich Z677558, Size M). Remarks : This recommendation applies only to the product stated in the safety data sheet, supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN 16523-1 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de).

Eyes

Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Safety glasses

Respiratory

required when dusts/vapours/aerosols are generated. Our recommendations on filtering respiratory protection are based on the following standards: DIN EN 143, DIN 14387 and other accompanying standards relating to the used respiratory protection system. Recommended Filter : Filter A-(P2) type: The entrepreneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.

Skin/Body

protective clothing

Environmental

Do not let product enter drains.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Voc Content
---
Evaporation Rate
No data available
Lower Explosive Limit
No data available
Flammability
---
Melting Point
20 - 26 °C
Kinematic Viscosity
No data available
State Under Standard Conditions
---
Decomposition Temperature
No data available
Density
1,261 g/cm3 (25 °C)
Solubility In Water
100 g/l (25 °C)
Solidification Point
---
Boiling Point
104 °C (0,3 hPa); 285 °C
Vapor Density
---
Odor
No data available
Freezing Point
---
Form
crystalline
Flash Point
closed cup: 177 °C
Odor Threshold
---
Metal Corrosion
---
Cloud Point
---
Crystallisation Point
---
Appearance
---
Vapor Pressure
0,035 hPa (30 °C)
Bulk Density
---
Ph
No data available
Physical State
liquid (20 °C, 1.013 hPa)
Dynamic Viscosity
10,34 mPa.s (30 °C)
Physical State Data
liquid
Molecular Weight
120,17 g/mol
Explosive Limits
---
Auto Ignition Temperature
No data available
Solubility
---
Relative Evaporation Rate
---
Partition Coefficient
log Pow: < 0 (20 °C)
Solubility In Fat
---
Relative Density
---
Colour Intensity
---
Colour
colourless
Properties Status
---
Upper Explosive Limit
No data available
Softening Point
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is chemically stable under standard ambient conditions (room temperature).

Reactivity

Forms explosive mixtures with air on intense heating. A range from approx. 15 Kelvin below the flash point is to be rated as critical.

Hazardous reactions

Violent reactions possible with: Strong oxidizing agents

Avoid

Strong heating.

Incompatible

No data available

Decomposition

For Hazardous combustion products in the event of fire: see section 5

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Sulfolane?

The signal word is danger.

What is the physical form of Sulfolane?

Sulfolane is a liquid (20 °c, 1.013 hpa) with colourless color. It has no data available odor.

What is Sulfolane used for?

Laboratory chemicals, Manufacture of substances

What are the hazard statements for Sulfolane?

This substance has 3 hazard statements:

  • H302: Harmful if swallowed.
  • H360FD: May damage fertility. May damage the unborn child.
  • H373: May cause damage to organs (Immune system) through prolonged or repeated exposure.

What is the melting point of Sulfolane?

The melting point is 20 - 26 °C and the boiling point is 104 °C (0,3 hPa); 285 °C.