Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Formaldehyde solution 4%, buffered, pH 6.9 (approx. 10% Formalin solution) for histology
- Product Code
- 1.00496
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
In vitro diagnostic reagent, Reagent for analysis
Uses advised against
This product is not intended for consumer use.
Manufacturers & Suppliers
Merck Life Science BV
manufacturer
Ildefonse Vandammestraat 5/7B, B-1560 HOEILAART
+32 (0)3 899-1301
Emergency Contacts
CHEMTREC
+(32) 28 083237
Anti-poison centre
070 245245
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
GHS08
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
First Aid Measures
Emergency procedures for chemical exposure incidents
After inhalation: fresh air. Immediately call in physician. If breathing stops: immediately apply artificial respiration, if necessary also oxygen.
In case of skin contact: Take off immediately all contaminated clothing. Rinse skin with water/ shower. Consult a physician.
After eye contact: rinse out with plenty of water. Call in ophthalmologist. Remove contact lenses.
After swallowing: immediately make victim drink water (two glasses at most). Consult a physician.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.
For this substance/mixture no limitations of extinguishing agents are given.
Not combustible. Ambient fire may liberate hazardous vapours.
Firefighter Protection
Stay in danger area only with self-contained breathing apparatus. Prevent skin contact by keeping a safe distance or by wearing suitable protective clothing.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Do not breathe vapours, aerosols. Avoid substance contact. Ensure adequate ventilation. Evacuate the danger area, observe emergency procedures, consult an expert. Render harmless: Treatment with excess sodium hydrogen sulfite solution.
Do not let product enter drains.
Take up carefully with liquid-absorbent material (e.g. Chemizorb®). Dispose of properly. Clean up affected area.
Materials: liquid-absorbent material (e.g. Chemizorb®)
Related Products
Similar products with comparable safety profiles
Formaldehyde solution min. 37% free from acid stabilized with about 10% methanol and calcium carbonate for histology
---
Formaldehyde Solution 36% Histology Grade
---
Formaldehyde 4% aqueous solution, buffered Q path® Formalin 10%
CAS: 50-00-0
Formaldehyde Solution, 36%, For Histology, Glassware Washing and other General Applications
---
Formaldehyde solution
CAS: 50-00-0
4 – 6 % BUFFERED FORMALIN
---
Paraformaldehyde solution, 4% in PBS
---
Paraformaldehyde, 4% in PBS
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Work under hood. Do not inhale substance/mixture. Avoid generation of vapours/aerosols.
Tightly closed. Keep in a well-ventilated place. Keep locked up or in an area accessible only to qualified or authorised persons.
Immediately change contaminated clothing. Apply preventive skin protection. Wash hands and face after working with substance.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Material : Nitrile rubber, Break through time : 480 min, Glove thickness : 0,11 mm, Protective index : Full contact, Manufacturer : KCL 741 Dermatril® L; Material : Nitrile rubber, Break through time : 480 min, Glove thickness : 0,11 mm, Protective index : Splash contact, Manufacturer : KCL 741 Dermatril® L. Remarks : This recommendation applies only to the product stated in the safety data sheet, supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN 16523-1 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de).
Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Safety glasses
required when vapours/aerosols are generated. Our recommendations on filtering respiratory protection are based on the following standards: DIN EN 143, DIN 14387 and other accompanying standards relating to the used respiratory protection system. Recommended Filter type : Filter type ABEK. The entrepreneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.
protective clothing
Do not let product enter drains.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is chemically stable under standard ambient conditions (room temperature). Contains the following stabiliser(s): Methanol(1,082 %)
Explosible with air in a vaporous/gaseous state when heated.
tends to polymerise
Heating.
various metals, various alloys, various plastics, Magnesium, zinc alloys
In the event of fire: see section 5
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Formaldehyde solution 4%, buffered, pH 6.9 (approx. 10% Formalin solution) for histology?
The signal word is danger.
What is the physical form of Formaldehyde solution 4%, buffered, pH 6.9 (approx. 10% Formalin solution) for histology?
Formaldehyde solution 4%, buffered, pH 6.9 (approx. 10% Formalin solution) for histology is a liquid with colourless color. It has characteristic odor.
What is Formaldehyde solution 4%, buffered, pH 6.9 (approx. 10% Formalin solution) for histology used for?
In vitro diagnostic reagent, Reagent for analysis
What are the hazard statements for Formaldehyde solution 4%, buffered, pH 6.9 (approx. 10% Formalin solution) for histology?
This substance has 4 hazard statements:
- H317: May cause an allergic skin reaction.
- H332: Harmful if inhaled.
- H341: Suspected of causing genetic defects.
- H350: May cause cancer.
What is the melting point of Formaldehyde solution 4%, buffered, pH 6.9 (approx. 10% Formalin solution) for histology?
The melting point is No data available and the boiling point is ca. 100 °C (1,013 hPa).