NextSDS Logo
Safety Data Sheet EN

Sodium hydrogen carbonate AnalaR NORMAPUR® Reag. Ph.Eur.

CAS 144-55-8

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Sodium hydrogen carbonate AnalaR NORMAPUR® Reag. Ph.Eur.
Product Code
27778
Chemical Name
Sodium hydrogen carbonate
Synonyms
Sodium bicarbonate

Regulatory Identifiers

CAS Number
144-55-8 Check regulations →
REACH No.
01-2119457606-32-XXXX

Identified Uses

General chemical reagent

Uses advised against

The product, as such or as a component of a mixture, is not intended to be used by consumers (as defined by the REACH Regulation).

Manufacturers & Suppliers

V

VWR International Ltd.

national supplier

Hunter Boulevard, Magna Park, Lutterworth, LE17 4XN, UK

0800 22 33 44

Emergency Contacts

CareChem24

+44 (0) 1270 502894

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance

Substance name: Sodium hydrogen carbonate Molecular formula: NaHCO₃ Molecular weight: 84.01 g/mol CAS No.: 144-55-8 EU REACH registration No.: 01-2119457606-32-XXXX EC No.: 205-633-8 ATE, SCL and/or M-factor: none

Chemical Name CAS Number Concentration Hazardous
Sodium hydrogen carbonate EC: 205-633-8 144-55-8 --- No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove casualty to fresh air and keep warm and at rest. Obtain medical attention if symptoms appear.

Skin contact

Gently wash with plenty of soap and water. In case of skin reactions, consult a physician.

Eye contact

Rinse immediately carefully and thoroughly with eye-bath or water. Obtain medical attention if symptoms appear.

Ingestion

Rinse mouth thoroughly with water. Call a doctor if you feel unwell.

Medical Treatment

No special information on medical attention and special treatment available.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

ABC-powder, Carbon dioxide (CO2), Dry sand, Nitrogen

Unsuitable media

Full water jet

Specific hazards

Non-combustible solids. The product itself does not burn. Fire may produce irritating, corrosive and/or toxic gases.

Instructions

Co-ordinate fire-fighting measures to the fire surroundings. In case of fire and/or explosion do not breathe fumes. In case of fire: Evacuate area.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Do not breathe dust. Remove victim out of the danger area. Remove victim to fresh air and keep at rest in a position comfortable for breathing.

Environmental

No special environmental measures are necessary.

Cleanup methods

Take up mechanically, placing in appropriate containers for disposal. Rinse affected areas with water.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Wash hands before breaks and after work. Avoid contact with eyes and skin. When using do not eat, drink or smoke. Provide eye shower and label its location conspicuously.

Storage

Store in a dry place. Store in a closed container. Keep the packing dry and well sealed to prevent contamination and absorbtion of humidity. Keep away from heat.

Hygiene

Wash hands before breaks and after work. Avoid contact with eyes and skin. When using do not eat, drink or smoke. Provide eye shower and label its location conspicuously.

Fire prevention

No special measures are necessary.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Technical measures and the application of suitable work processes have priority over personal protection equipment. If handled uncovered, arrangements with local exhaust ventilation have to be used.

Hands

When handling with chemical substances, protective gloves must be worn with the CE-label including the four control digits. Recommended glove articles DIN-/EN-Norms EN ISO 374 In the case of wanting to use the gloves again, clean them before taking off and air them well. By short-term hand contact Suitable material: NBR (Nitrile rubber) Thickness of the glove material: 0,12 mm Breakthrough time: > 480 min Recommended glove articles: VWR 112-0998

Eyes

Eye glasses with side protection DIN-/EN-Norms EN 166 Recommendation: VWR 111-0432

Respiratory

Usually no personal respirative protection necessary. Suitable respiratory protection apparatus: no data available Recommendation: no data available Suitable material: no data available Recommendation: no data available

Skin/Body

Wear suitable protective clothing. When handling with chemical substances, protective clothing with CE-labels including the four control digits must be worn.

Environmental

no data available

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
solid
Physical State Data
solid
State Under Standard Conditions
---
Appearance
---
Colour
white
Colour Intensity
---
Form
---
Odor
no data available
Odor Threshold
---
Ph
8-9 (50 g/l; H2O; 20 °C)
Melting Point
270 °C
Boiling Point
400 °C (1013 hPa)
Flash Point
no data available
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
no data available
Vapor Pressure
8.3 hPa (30 °C)
Vapor Density
---
Relative Density
---
Bulk Density
no data available
Density
2.159 g/cm³ (20 °C)
Flammability
Not applicable
Upper Explosive Limit
no data available
Lower Explosive Limit
no data available
Explosive Limits
---
Auto Ignition Temperature
no data available
Decomposition Temperature
50 °C (1013 hPa)
Solubility
---
Partition Coefficient
no data available
Solubility In Water
95 g/l (20 °C)
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
no data available
Kinematic Viscosity
no data available
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is chemically stable under standard ambient conditions (room temperature).

Reactivity

This material is non-reactive under normal conditions.

Hazardous reactions

Reaction with: Acids.

Avoid

Keep away from heat.

Incompatible

No further relevant information available.

Decomposition

Decomposition products in case of fire: see section 5.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What other names is Sodium hydrogen carbonate AnalaR NORMAPUR® Reag. Ph.Eur. known by?

Sodium hydrogen carbonate AnalaR NORMAPUR® Reag. Ph.Eur. is also known as: Sodium bicarbonate

What is the hazard signal word for Sodium hydrogen carbonate AnalaR NORMAPUR® Reag. Ph.Eur.?

The signal word is no signal word.

What is the physical form of Sodium hydrogen carbonate AnalaR NORMAPUR® Reag. Ph.Eur.?

Sodium hydrogen carbonate AnalaR NORMAPUR® Reag. Ph.Eur. is a solid with white color. It has no data available odor.

What is Sodium hydrogen carbonate AnalaR NORMAPUR® Reag. Ph.Eur. used for?

General chemical reagent

What is the melting point of Sodium hydrogen carbonate AnalaR NORMAPUR® Reag. Ph.Eur.?

The melting point is 270 °C and the boiling point is 400 °C (1013 hPa).