Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Methanol AnalaR NORMAPUR® Reag. Ph.Eur., ACS Analytical Reagent
- Product Code
- 20847
- Chemical Name
- Methanol
- Synonyms
- Carbinol, Hydroxy methane, Methyl alcohol, Wood alcohol
Regulatory Identifiers
- CAS Number
- 67-56-1 Check regulations →
- REACH No.
- 01-2119433307-44-XXXX
Identified Uses
General chemical reagent
Manufacturers & Suppliers
VWR International Ltd.
distributor
Hunter Boulevard, Magna Park, Lutterworth, LE17 4XN
0800 22 33 44
Emergency Contacts
CareChem24
+44 (0) 1270 502894
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS06
GHS08
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Substance name: Methanol Molecular formula: H₃COH
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Methanol EC: 200-659-6 | 67-56-1 | --- | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Immediately call a POISON CENTRE/doctor. Remove casualty to fresh air and keep warm and at rest. If breathing is irregular or stopped, administer artificial respiration.
Symptoms: Respiratory disorders.
After contact with skin, wash immediately with plenty of water and soap. Remove contaminated, saturated clothing immediately. In case of skin reactions, consult a physician.
In case of contact with eyes flush immediately with plenty of flowing water for 10 to 15 minutes holding eyelids apart and consult an ophthalmologist. Protect uninjured eye. Remove contact lenses, if present and easy to do. Continue rinsing.
Symptoms: Risk of blindness.
Immediately call a POISON CENTRE/doctor. Do NOT induce vomiting. Rinse mouth thoroughly with water. Give nothing to eat or drink.
Symptoms: Nausea.
Immediate Medical Attention
Immediately call a POISON CENTRE/doctor.
Medical Treatment
Treat symptomatically. Following ingestion: Administer 50 ml of pure ethanol in a drinkable concentration.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water spray, ABC-powder, Carbon dioxide (CO2), Nitrogen
Full water jet
In case of fire may be liberated: Carbon monoxide, Carbon dioxide (CO2). Vapours are heavier than air, spread along floors and form explosive mixtures with air.
In case of fire and/or explosion do not breathe fumes. Use water spray jet to protect personnel and to cool endangered containers. DO NOT fight fire when fire reaches explosives. In case of fire: Evacuate area.
Firefighter Protection
Wear a self-contained breathing apparatus and chemical protective clothing. Use water spray jet to protect personnel and to cool endangered containers.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Avoid contact with skin, eyes and clothes. Avoid inhalation of the product. Take off immediately all contaminated clothing.
Discharge into the environment must be avoided.
Collect in closed and suitable containers for disposal.
Related Products
Similar products with comparable safety profiles
Ethanol absolute AnalaR NORMAPUR® Reag. Ph. Eur., Reag. USP, ACS
CAS: 64-17-5
4-Methyl-2-pentanone AnalaR NORMAPUR® ACS, Reag. Ph. Eur. analytical reagent
CAS: 108-10-1
Acetone AnalaR NORMAPUR® Reag. Ph. Eur., Reag. USP, ACS
CAS: 67-64-1
Methanol for analysis EMSURE® ACS,ISO,Reag. Ph Eur
CAS: 67-56-1
Ethylenediaminetetraacetic acid disodium salt dihydrate AnalaR NORMAPUR® Reag. Ph.Eur., ACS Analytical Reagent
CAS: 6381-92-6
Ammonium acetate AnalaR NORMAPUR® Reag. Ph.Eur., ACS
CAS: 631-61-8
Cyclohexane AnalaR NORMAPUR® Reag. Ph.Eur., ACS
CAS: 110-82-7
Ammonium thiocyanate AnalaR NORMAPUR® Reag. Ph. Eur. analytical reagent
CAS: 1762-95-4
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid inhalation of the product. Avoid contact with eyes and skin. Wear protective gloves/protective clothing and eye/face protection. Use extractor hood (laboratory). If handled uncovered, arrangements with local exhaust ventilation have to be used. If local exhaust ventilation is not possible or not sufficient, the entire working area must be ventilated by technical means. Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. Take precautionary measures against static discharges.
Recommended storage temperature: 15-25°C. Keep container tightly closed and in a well-ventilated place. Keep cool. Protect from sunlight. Store in a place accessible by authorized persons only. Keep/Store away from combustible materials. Ground and bond container and receiving equipment. Provide adequate ventilation.
Wash hands before breaks and after work. Avoid contact with eyes and skin. When using do not eat, drink or smoke. Provide eye shower and label its location conspicuously.
Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. Take precautionary measures against static discharges. Usual measures for fire prevention.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is chemically stable under standard ambient conditions (room temperature).
This material is non-reactive under normal conditions.
Formation of explosive mixtures with: Oxidising agent Nitrogen oxides (NOx) Chlorates Nitric acid Sulphuric acid. Exothermic reaction with: Reducing agent Acid Acid halides Alkali (lye), concentrated Violent reaction with: Alkali metals Alkaline earth metal Formation of: Hydrogen
UV-radiation/sunlight Heat Sparks. Flame
Acids Alkali metals Oxidising agent
Formaldehyde
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1230
- Shipping Name
- METHANOL
- Transport Class
- 3 (6.1)
- Packing Group
- II
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is Methanol AnalaR NORMAPUR® Reag. Ph.Eur., ACS Analytical Reagent known by?
Methanol AnalaR NORMAPUR® Reag. Ph.Eur., ACS Analytical Reagent is also known as: Carbinol, Hydroxy methane, Methyl alcohol, Wood alcohol
What is the hazard signal word for Methanol AnalaR NORMAPUR® Reag. Ph.Eur., ACS Analytical Reagent?
The signal word is danger.
What is the physical form of Methanol AnalaR NORMAPUR® Reag. Ph.Eur., ACS Analytical Reagent?
Methanol AnalaR NORMAPUR® Reag. Ph.Eur., ACS Analytical Reagent is a liquid appearing as liquid colourless characteristic with colourless color. It has characteristic odor.
What is Methanol AnalaR NORMAPUR® Reag. Ph.Eur., ACS Analytical Reagent used for?
General chemical reagent
What are the hazard statements for Methanol AnalaR NORMAPUR® Reag. Ph.Eur., ACS Analytical Reagent?
This substance has 3 hazard statements:
- H225: Highly flammable liquid and vapour.
- H301 + H311 + H331: Toxic if swallowed, in contact with skin or if inhaled.
- H370: Causes damage to organs.
What is the melting point of Methanol AnalaR NORMAPUR® Reag. Ph.Eur., ACS Analytical Reagent?
The melting point is -98 °C and the boiling point is 64.6 °C (1013 hPa).