Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Hypower HVI 32
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Hydraulic fluid
Uses advised against
Processes involving extreme heat use advised against.
Manufacturers & Suppliers
Smith & Allan
manufacturer
Valley Street North, Darlington, County Durham, DL1 1QE
01325 462228
Emergency Contacts
UK National Poisons Information Service
+44 (0)344 892 0111
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
A blend of highly refined mineral oils with multifunctional additives.
For the wording of the listed hazard phrases refer to section 16.
First Aid Measures
Emergency procedures for chemical exposure incidents
Supply fresh air; consult doctor in case of complaints.
Immediately wash with water and soap and rinse thoroughly. If skin irritation continues, consult a doctor.
Check for and remove any contact lenses. Rinse opened eye for several minutes under running water. Then consult a doctor.
Wash mouth out with water. Do not induce vomiting; call for medical help immediately. If vomiting occurs spontaneously, keep head below hips to prevent aspiration.
Immediate Medical Attention
Call for medical help immediately (in case of swallowing). High pressure injection injuries of mineral and synthetic oils through the skin require prompt surgical intervention.
Medical Treatment
High pressure injection injuries of mineral and synthetic oils through the skin require prompt surgical intervention and possibly steroid therapy, to minimise tissue damage and loss of function. Because entry wounds are small and do not reflect the seriousness of the underlying damage, surgical exploration to determine the extent of involvement may be necessary. Prompt surgical decompression, debridement and evacuation of foreign material should be performed under general anaesthetics, and wide exploration is essential.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
CO2, powder or water spray. Fight larger fires with water spray or alcohol resistant foam.
Water with full jet
Combustible
Firefighter Protection
Wear self-contained respiratory protective device. Wear fully protective suit.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Particular danger of slipping on leaked/spilled product.
Do not allow to penetrate the ground/soil. Do not allow to enter sewers/ surface or ground water.
Absorb with liquid-binding material
Materials: sand, diatomite, acid binders, universal binders, sawdust
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Prevent formation of aerosols. Ensure good ventilation/exhaustion at the workplace.
Store in cool, dry conditions in well sealed receptacles.
No special measures required.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.
Safety glasses. Goggles recommended during refilling
Not necessary if room is well-ventilated.
Oil resistant protective clothing. Body protection must be chosen depending on product properties, activity and possible exposure.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No decomposition if used and stored according to specifications.
No further relevant information available.
No dangerous reactions known.
No decomposition if used and stored according to specifications.
Strong oxidising agents.
Carbon monoxide and carbon dioxide
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Hypower HVI 32?
The signal word is no signal word.
What is the physical form of Hypower HVI 32?
Hypower HVI 32 is a liquid appearing as brown with brown color. It has characteristic odor.
What is Hypower HVI 32 used for?
Hydraulic fluid
What is the melting point of Hypower HVI 32?
The melting point is Undetermined. and the boiling point is Undetermined..