Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Tracer (iodine 125 Ab)
- Product Form
- Mixture
- Product Code
- 3104263
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Laboratory reagent, Immunoassays Use by professionals
Uses advised against
No additional information available
Manufacturers & Suppliers
DIAsource ImmunoAssays S.A.
manufacturer
Rue du Bosquet, 2 B-1348 Louvain-la-Neuve Belgium
+32 (0)10/84.99.11
Emergency Contacts
DIAsource
+32 (0)10/84.99.23
only office hours
Centre Anti-Poisons (BE)
070 245 245
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Sodium Azide EC: 247-852-1 | 26628-22-8 | 0.05% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove victim to fresh air and keep at rest in a position comfortable for breathing.
Take off immediately all contaminated clothing. Gently wash with plenty of soap and water.
IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
Rinse mouth. Do NOT induce vomiting. Drink plenty of water as a precaution.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Adapt extinguishing agents to the environment. Carbon dioxide. Foam. Dry extinguishing powder. Water spray.
Do not use a heavy water stream.
Toxic gases may be formed.
Prevent firefighting water from entering the environment. Use water spray or fog for cooling exposed containers.
Firefighter Protection
Use a self-contained breathing apparatus and also a protective suit.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Evacuate unnecessary personnel.
Contain spill to prevent migration.
Absorb spills to prevent radioactive contamination. Absorb spills with absorbent material, such as paper towels. Decontaminate with suitable products.
Materials: absorbent material, such as paper towels
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Ensure good ventilation of the work station. Wear personal protective equipment. Avoid contact with skin and eyes. Do not breathe vapour/aerosol.
Store in original container. Keep container tightly closed. To maintain product quality, store according to the instructions in the product labeling.
Handle in accordance with good industrial hygiene and safety procedures. When using do not eat, drink or smoke. Wash hands and other exposed areas with mild soap and water before eating, drinking or smoking and when leaving work.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Provide local exhaust or general room ventilation to minimize vapour concentrations.
Wear suitable gloves (EN 374). Nitrile rubber, 0.35 mm. Butyl rubber, 0.5 mm. The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.
Wear safety glasses (EN 166).
Under normal conditions, the use of this product should not require respiratory protection.
Wear suitable protective clothing.
Avoid release to the environment.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under use and storage conditions as recommended in section 7.
No dangerous reactions known under normal conditions of use.
None under normal use.
Avoid exposure to heat and direct sunlight.
No additional information available.
No hazardous decomposition products known at room temperature. In case of fire: Toxic gases may be formed. Carbon dioxide. Carbon monoxide.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Tracer (iodine 125 Ab)?
The signal word is no signal word.
What is the physical form of Tracer (iodine 125 Ab)?
Tracer (iodine 125 Ab) is a liquid with red color. It has odorless odor.
What is the solubility of Tracer (iodine 125 Ab)?
No data available
What is Tracer (iodine 125 Ab) used for?
Laboratory reagent, Immunoassays Use by professionals
What is the melting point of Tracer (iodine 125 Ab)?
The melting point is No data available and the boiling point is No data available.