Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Frostox® HT12
- Product Code
- 10330
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Radiator anti-freeze
Manufacturers & Suppliers
HAERTOL Chemie GmbH
manufacturer
Havelstr. 21 39126 Magdeburg
+49 391 2800 231
Emergency Contacts
Emergency Contact
+49 6132 / 84463
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
GHS08
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Ethylene glycol EC: 203-473-3 | 107-21-1 | 90 - 100% | Yes |
| Disodium sebacate EC: 241-300-3 | 17265-14-4 | 1 - 10% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
If inhaled, remove to fresh air. Get medical attention if symptoms occur.
Wash with water and soap as a precaution. Get medical attention if symptoms occur.
Flush eyes with water as a precaution. Get medical attention if irritation develops and persists.
If swallowed, DO NOT induce vomiting unless directed to do so by medical personnel. Get medical attention. Rinse mouth thoroughly with water. Never give anything by mouth to an unconscious person.
Symptoms: Harmful if swallowed.
Immediate Medical Attention
Get medical attention if symptoms occur or if irritation develops and persists.
Medical Treatment
Treat symptomatically and supportively.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water spray, Alcohol-resistant foam, Carbon dioxide (CO2), Dry chemical
None known.
Exposure to combustion products may be a hazard to health.
Use extinguishing measures that are appropriate to local circumstances and the surrounding environment. Use water spray to cool unopened containers. Remove undamaged containers from fire area if it is safe to do so.
Firefighter Protection
In the event of fire, wear self-contained breathing apparatus. Use personal protective equipment.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Use personal protective equipment. Follow safe handling advice and personal protective equipment recommendations.
For large spills, provide dyking or other appropriate containment to keep material from spreading. If dyked material can be pumped, store recovered material in appropriate container.
Discharge into the environment must be avoided. Prevent further leakage or spillage if safe to do so.
Soak up with inert absorbent material. Clean up remaining materials from spill with suitable absorbent.
Materials: inert absorbent material, suitable absorbent
Related Products
Similar products with comparable safety profiles
TYFOCOR® G-LS –ready-to-use, frost protection –28 °C
---
Anti-Frost -70°C
UFI: 8W7D-S0SQ-500Y-WGT4
Frigutec® OAT+
UFI: 1QD4-GRJ1-M30W-4S6A
Frigutec® X-OAT
UFI: GYD4-0RM7-J30D-4SXH
Kilfrost Cooltrans Plus CTL
---
Frigutec® OAT-Si++
UFI: 48XS-8URT-R00P-TKUY
Frigutec® OAT-EVO
UFI: JH0T-EUQ4-Q00J-0G0N
Frigutec® OAT-EVO
UFI: JH0T-EUQ4-Q00J-0G0N
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid inhalation of vapour or mist. Do not swallow. Avoid contact with eyes. Avoid prolonged or repeated contact with skin. Handle in accordance with good industrial hygiene and safety practice, based on the results of the workplace exposure assessment
Keep in properly labelled containers. Store in accordance with the particular national regulations. Keep in a dry place.
Ensure that eye flushing systems and safety showers are located close to the working place. When using do not eat, drink or smoke. Wash contaminated clothing before re-use.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Ensure adequate ventilation, especially in confined areas. Minimize workplace exposure concentrations.
Material: butyl-rubber, Break through time: > 30 min, Glove thickness: 0,7 mm, Directive: DIN EN 374, Protective index: Class 2; Material: Nitrile rubber, Break through time: > 30 min, Glove thickness: 0,4 mm, Directive: DIN EN 374, Protective index: Class 2. Remarks: Choose gloves to protect hands against chemicals depending on the concentration and quantity of the hazardous substance and specific to place of work. For special applications, we recommend clarifying the resistance to chemicals of the aforementioned protective gloves with the glove manufacturer.
Wear the following personal protective equipment: Safety glasses Equipment should conform to DIN EN 166
Use respiratory protection unless adequate local exhaust ventilation is provided or exposure assessment demonstrates that exposures are within recommended exposure guidelines. Filter type: Combined particulates and organic vapour type (A-P)
Skin should be washed after contact.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
Not classified as a reactivity hazard.
Can react with strong oxidizing agents.
None known.
Oxidizing agents
No hazardous decomposition products are known.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
12.1 Toxicity
12.2 Persistence and degradability
12.2 Persistence and degradability
12.2 Persistence and degradability
12.3 Bioaccumulative potential
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
12.6 Other adverse effects
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Dispose of in accordance with local regulations.
According to the European Waste Catalogue, Waste Codes are not product specific, but application specific. Waste codes should be assigned by the user, preferably in discussion with the waste disposal authorities.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Take note of Law on the protection of mothers at work, in education and in studies (Maternity Protection Act - MuSchG). Take note of Directive 94/33/EC on the protection of young people at work or stricter national regulations, where applicable.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Frostox® HT12?
The signal word is warning.
What is the physical form of Frostox® HT12?
Frostox® HT12 is a liquid appearing as liquid with customer specific color. It has characteristic odor.
What is Frostox® HT12 used for?
Radiator anti-freeze
What are the hazard statements for Frostox® HT12?
This substance has 2 hazard statements:
- H302: Harmful if swallowed.
- H373: May cause damage to organs through prolonged or repeated exposure.
What is the melting point of Frostox® HT12?
The melting point is No data available and the boiling point is > 170 °C Method: ASTM D 1120-72.