Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- PRIMOL 352
- Product Code
- 406949, 451010202010, 730515-60
- Chemical Name
- White mineral oil (petroleum)
Regulatory Identifiers
- CAS Number
- 8042-47-5 Check regulations →
- REACH No.
- 01-2119487078-27
Identified Uses
Manufacture of substance Distribution of substance Formulation and (re)packing of substances and mixtures Use in Coatings - Industrial Lubricants - Industrial Functional Fluids - Industrial Use in laboratories - Industrial Rubber production and processing Polymer production - Industrial Use in Coatings - Professional Lubricants - Professional (Low Release) Lubricants - Professional (High Release) Agrochemical uses - Professional Functional Fluids - Professional Use in laboratories - Professional Use in Coatings - Consumer Lubricants - Consumer (Low Release) Lubricants - Consumer (High Release) Agrochemical uses - Consumer Uses in cosmetics/personal care products, perfumes and fragrances – Consumer
Uses advised against
None unless specified elsewhere in this SDS.
Manufacturers & Suppliers
ExxonMobil Petroleum & Chemical BV
manufacturer
POLDERDIJKWEG B-2030 Antwerpen Belgium
0800 028 2851
http://www.msds.exxonmobil.com
Emergency Contacts
Emergency Contact
(+44) 870 8200418
24 Hour
National Poison Control Centre
111
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
No Hazardous Substance(s) required for disclosure.
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove from further exposure. For those providing assistance, avoid exposure to yourself or others. Use adequate respiratory protection. If breathing has stopped, assist ventilation with a mechanical device or use mouth-to-mouth resuscitation.
Symptoms: respiratory irritation, dizziness, nausea, or unconsciousness
Wash contact areas with soap and water. If product is injected into or under the skin, or into any part of the body, regardless of the appearance of the wound or its size, the individual should be evaluated immediately by a physician as a surgical emergency.
Symptoms: initial symptoms from high pressure injection may be minimal or absent
Flush thoroughly with water.
Symptoms: irritation
First aid is normally not required.
Symptoms: discomfort
Immediate Medical Attention
If respiratory irritation, dizziness, nausea, or unconsciousness occurs, seek immediate medical assistance. If product is injected into or under the skin, or into any part of the body, the individual should be evaluated immediately by a physician as a surgical emergency. Seek medical attention if discomfort occurs after ingestion.
Medical Treatment
Early surgical treatment within the first few hours may significantly reduce the ultimate extent of injury for high pressure injection.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use water fog, foam, dry chemical or carbon dioxide (CO2) to extinguish flames.
Straight streams of water
Evacuate area. Prevent run-off from fire control or dilution from entering streams, sewers or drinking water supply. Use water spray to cool fire exposed surfaces and to protect personnel.
Firefighter Protection
Fire-fighters should use standard protective equipment and in enclosed spaces, self-contained breathing apparatus (SCBA).
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Avoid contact with spilled material.
normal antistatic work clothes are usually adequate.
full body suit of chemical resistant, antistatic material is recommended.
Dyke far ahead of liquid spill for later recovery and disposal. Prevent entry into waterways, sewers, basements or confined areas.
Recover by pumping or with suitable absorbent. Remove from the surface by skimming or with suitable absorbents.
Materials: absorbent, booms, skimming
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Prevent small spills and leakage to avoid slip hazard. Material can accumulate static charges which may cause an electrical spark (ignition source). When the material is handled in bulk, an electrical spark could ignite any flammable vapors from liquids or residues that may be present (e.g., during switch-loading operations). Use proper bonding and/or earthing procedures. However, bonding and earthing may not eliminate the hazard from static accumulation.
The type of container used to store the material may affect static accumulation and dissipation. Do not store in open or unlabelled containers.
Use proper bonding and/or earthing procedures. Consult local applicable standards for guidance. Additional references include American Petroleum Institute 2003 (Protection Against Ignitions Arising out of Static, Lightning and Stray Currents) or National Fire Protection Agency 77 (Recommended Practice on Static Electricity) or CENELEC CLC/TR 50404 (Electrostatics - Code of practice for the avoidance of hazards due to static electricity).
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
No special requirements under ordinary conditions of use and with adequate ventilation.
No protection is ordinarily required under normal conditions of use.
If contact is likely, safety glasses with side shields are recommended.
If engineering controls do not maintain airborne contaminant concentrations at a level which is adequate to protect worker health, an approved respirator may be appropriate. Respirator selection, use, and maintenance must be in accordance with regulatory requirements, if applicable. Types of respirators to be considered for this material include: No special requirements under ordinary conditions of use and with adequate ventilation. For high airborne concentrations, use an approved supplied-air respirator, operated in positive pressure mode. Supplied air respirators with an escape bottle may be appropriate when oxygen levels are inadequate, gas/vapour warning properties are poor, or if air purifying filter capacity/rating may be exceeded.
No skin protection is ordinarily required under normal conditions of use. In accordance with good industrial hygiene practices, precautions should be taken to avoid skin contact.
Comply with applicable environmental regulations limiting discharge to air, water and soil. Protect the environment by applying appropriate control measures to prevent or limit emissions.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Material is stable under normal conditions.
See sub-sections below.
Hazardous polymerization will not occur.
Excessive heat. High energy sources of ignition.
Strong oxidisers
Material does not decompose at ambient temperatures.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1. TOXICITY
12.2. PERSISTENCE AND DEGRADABILITY
12.3. BIOACCUMULATIVE POTENTIAL
12.4. MOBILITY IN SOIL
12.5. PERSISTENCE, BIOACCUMULATION AND TOXICITY FOR SUBSTANCE(S)
The material does not meet the REACH Annex XIII criteria for PBT or vPvB.
12.6. OTHER ADVERSE EFFECTS
No adverse effects are expected.
Ecotoxicity
Persistence, Degradability and Bioaccumulation Potential
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Product is suitable for burning in an enclosed controlled burner for fuel value or disposal by supervised incineration at very high temperatures to prevent formation of undesirable combustion products.
Dispose of used oil at designated sites. Minimize skin contact. Do not mix used oils with solvents, brake fluids or coolants.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Applicable UK legislation: REACH, CLP
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for PRIMOL 352?
The signal word is no signal word.
What is the physical form of PRIMOL 352?
PRIMOL 352 is a liquid with colourless color. It has odourless odor.
What is PRIMOL 352 used for?
Manufacture of substance Distribution of substance Formulation and (re)packing of substances and mixtures Use in Coatings - Industrial Lubricants - Industrial Functional Fluids - Industrial Use in laboratories - Industrial Rubber production and processing Polymer production - Industrial Use in Coatings - Professional Lubricants - Professional (Low Release) Lubricants - Professional (High Release) Agrochemical uses - Professional Functional Fluids - Professional Use in laboratories - Professional Use in Coatings - Consumer Lubricants - Consumer (Low Release) Lubricants - Consumer (High Release) Agrochemical uses - Consumer Uses in cosmetics/personal care products, perfumes and fragrances – Consumer
What is the melting point of PRIMOL 352?
The melting point is Not technically feasible and the boiling point is No data available.