NextSDS Logo
Safety Data Sheet EN

LUBRIZOL® MF9145D

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
LUBRIZOL® MF9145D

Regulatory Identifiers

CAS Number
N/A
UFI Code
D5GM-V2V5-100C-P7H0

Identified Uses

Miscellaneous fuel additive

Uses advised against

None identified.

Manufacturers & Suppliers

LUBRIZOL FRANCE logo

LUBRIZOL FRANCE

manufacturer

25 QUAI DE FRANCE CS 61062 76173 ROUEN CEDEX, 76173 FR

(33) 02.35.58.14.00

http://www.mylubrizol.com

Emergency Contacts

CHEMTREC

(+1) 703 527 3887

Emergency Contact

09.75.18.14.07

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Hydrocarbons, C10-C13, n-alkanes, isoalkanes, cyclics, less than 2% aromatics EC: 918-481-9 --- 20 - 50% Yes
2-Ethylhexan-1-ol EC: 203-234-3 --- 5 - 10% Yes
Distillates (petroleum), hydrotreated heavy paraffinic EC: 265-157-1 --- 1 - 10% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove exposed person to fresh air if adverse effects are observed.

Skin contact

Take off contaminated clothing and wash before re-use. Wash with soap and water. If skin irritation occurs, get medical attention. Get medical attention if symptoms occur. Launder contaminated clothing before reuse.

Eye contact

Flush thoroughly with water. If irritation occurs, get medical assistance. Remove contact lenses, if present and easy to do. Continue rinsing.

Ingestion

Rinse mouth. Get medical attention if symptoms occur.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

CO2, Dry chemical or Foam. Water can be used to cool and protect exposed material.

Unsuitable media

Do not use water jet as an extinguisher, as this will spread the fire.

Specific hazards

Vapors may cause a flash fire or ignite explosively. Prevent buildup of vapors or gases to explosive concentrations. Vapors may travel considerable distance to a source of ignition and flash back. Water may cause splattering. Container may rupture on heating. Material creates a special hazard because it floats on water. See section 10 for additional information.

Instructions

Move containers from fire area if you can do so without risk.

Firefighter Protection

Firefighters must use standard protective equipment including flame retardant coat, helmet with face shield, gloves, rubber boots, and in enclosed spaces, SCBA.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

ELIMINATE all ignition sources (no smoking, flares, sparks or flames in immediate area).

Large spill

Dike far ahead of larger spill for later recovery and disposal.

Environmental

Prevent further leakage or spillage if safe to do so.

Cleanup methods

Pick up free liquid for recycle and/or disposal. Residual liquid can be absorbed on inert material.

Materials: inert material

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. Observe good industrial hygiene practices. Provide adequate ventilation. Wear appropriate personal protective equipment. Material can accumulate static charges which may cause an electrical spark (ignition source). In case of spills, beware of slippery floors and surfaces.

Storage

Keep cool. Store in a well-ventilated place. Store away from incompatible materials. See section 10 for incompatible materials. Do not store near potential sources of ignition.

Hygiene

Observe good industrial hygiene practices.

Fire prevention

Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No special requirements under ordinary conditions of use and with adequate ventilation. Adequate ventilation should be provided so that exposure limits are not exceeded.

Hands

Use nitrile or neoprene gloves. Chemical resistant gloves. For typical use and handling of chemical substances, gloves should meet the standards set out in EN 374. For applications involving mechanical risks with potential for abrasion or puncture, the standards set out in EN 388 should be considered. For continuous contact, we suggest gloves with a minimum breakthrough time of 240 minutes, or > 480 minutes if suitable gloves can be obtained. For general applications, we recommend gloves with a thickness typically greater than 0.35 mm.

Eyes

Safety glasses. If potential for splash or mist exists, wear chemical goggles or faceshield. Eye protection should meet the standards set out in EN 166.

Respiratory

A respiratory protection program compliant with all applicable regulations must be followed whenever workplace conditions require the use of a respirator. Under normal use conditions, respirator is not usually required. Use appropriate respiratory protection if exposure to dust particles, mist or vapors is likely. Use self-contained breathing apparatus for entry into confined space, for other poorly ventilated areas and for large spill clean-up sites. Use respirator with a combination organic vapor and dust/mist cartridge. Use disposable dust/mist mask if the recommended exposure limit is exceeded. Respiratory Protective Equipment (RPE) is not normally required where there is adequate natural or local exhaust ventilation to control exposure. In case of insufficient ventilation, wear suitable respiratory equipment.

Skin/Body

Wear apron or protective clothing in case of contact. Gloves, coveralls, apron, boots as necessary to minimize contact.

Environmental

No data available. See section 6 for details.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
liquid
Colour
Amber
Colour Intensity
---
Form
liquid
Odor
Characteristic
Odor Threshold
No data available.
Ph
Not applicable
Melting Point
---
Boiling Point
No data available.
Flash Point
61 °C (Pensky-Martens Closed Cup)
Freezing Point
No data available.
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
---
Vapor Density
---
Relative Density
0.862 - 0.902 (15.6 °C)
Bulk Density
7.35 lb/gal (15.6 °C)
Density
---
Flammability
---
Upper Explosive Limit
No data available.
Lower Explosive Limit
No data available.
Explosive Limits
---
Auto Ignition Temperature
No data available.
Decomposition Temperature
No data available.
Solubility
---
Partition Coefficient
---
Solubility In Water
Insoluble in water
Solubility In Fat
---
Molecular Weight
---
Voc Content
No data available.
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
135.3 mm2/s (40 °C); 2072 mm2/s (0 °C) 14950 mm2/s (-18 °C)
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Material is stable under normal conditions.

Reactivity

No data available.

Hazardous reactions

Will not occur.

Avoid

Heat, sparks, flames. Do not expose to excessive heat, ignition sources, or oxidizing materials.

Incompatible

oxidizing materials

Decomposition

Thermal decomposition or combustion may generate smoke, carbon monoxide, carbon dioxide, and other products of incomplete combustion.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.7 Other adverse effects

No data available

12.1 Ecotoxicity

Fish Hydrocarbons, C10-C13, n-alkanes, isoalkanes, cyclics, less than 2% aromatics LL 50 (Oncorhynchus mykiss, 96 h): > 1,000 mg/l

12.1 Ecotoxicity

Fish 2-Ethylhexan-1-ol LC 50 (Fathead Minnow, 4 d): 28.2 mg/l LC 50 (Golden Orfe, 4 d): 17.1 mg/l

12.1 Ecotoxicity

Fish Distillates (petroleum), hydrotreated heavy paraffinic LC 50 (Fathead Minnow, 96 h): > 100 mg/l

12.1 Ecotoxicity

Aquatic Invertebrates Hydrocarbons, C10-C13, n-alkanes, isoalkanes, cyclics, less than 2% aromatics EC 50 (Water Flea (Daphnia Magna), 48 h): > 1,000 mg/l

12.1 Ecotoxicity

Aquatic Invertebrates 2-Ethylhexan-1-ol EC 50 (Water flea (Daphnia magna), 2 d): 39 mg/l

12.1 Ecotoxicity

Aquatic Invertebrates Distillates (petroleum), hydrotreated heavy paraffinic EC 50 (Water flea (Daphnia magna), 48 h): > 10,000 mg/l EC 50 (Water flea (Daphnia magna), 21 d): > 10 mg/l NOEC (Water flea (Daphnia magna), 21 d): 10 mg/l

12.1 Ecotoxicity

Toxicity to Aquatic Plants Hydrocarbons, C10-C13, n-alkanes, isoalkanes, cyclics, less than 2% aromatics EC 50 (Algae (Pseudokirchneriella subcapitata), 72 h): > 1,000 mg/l

12.1 Ecotoxicity

Toxicity to Aquatic Plants 2-Ethylhexan-1-ol EC 50 (Green algae (Scenedesmus quadricauda), 3 d): 16.6 mg/l

12.1 Ecotoxicity

Toxicity to Aquatic Plants Distillates (petroleum), hydrotreated heavy paraffinic EC 50 (Algae (Pseudokirchneriella subcapitata), 72 h): > 100 mg/l NOEC (Algae (Pseudokirchneriella subcapitata), 72 h): >= 100 mg/l

12.1 Ecotoxicity

Toxicity to microorganisms 2-Ethylhexan-1-ol EC 50 (Pseudomonas putida, 0.1 d): 540 mg/l EC 50 (Sludge, 0.5 d): > 100 mg/l

12.2 Persistence and Degradability

Biodegradation Hydrocarbons, C10-C13, n-alkanes, isoalkanes, cyclics, less than 2% aromatics OECD TG 301 F, 80 %, 28 d, Readily biodegradable

12.2 Persistence and Degradability

Biodegradation 2-Ethylhexan-1-ol OECD TG 302 B, 95 %, 5 d, Readily biodegradable OECD TG 301 C, 100 %, 14 d, Readily biodegradable

12.2 Persistence and Degradability

Biodegradation Distillates (petroleum), hydrotreated heavy paraffinic OECD TG 301 F, 31 %, 28 d, Not readily degradable.

12.2 Persistence and degradability

BOD/COD Ratio No data available

12.3 Bioaccumulative potential

Bioconcentration Factor (BCF)

12.3 Bioaccumulative potential

Bioconcentration Factor (BCF) 2-Ethylhexan-1-ol Bioconcentration Factor (BCF): 25.35 (calculated)

12.3 Bioaccumulative potential

Partition Coefficient n-octanol / water (log Kow) 2-Ethylhexan-1-ol Log Kow: 2.9 (Measured)

12.4 Mobility:

2-Ethylhexan-1-ol soil - 1.42

12.5 Results of PBT and vPvB assessment

No data available

12.6 Endocrine Disruption:

The substance/mixture does not contain components considered to have endocrine disrupting properties according to REACH Article 57(f) or Commission Delegated regulation (EU) 2017/2100 or Commission Regulation (EU) 2018/605 at levels of 0.1% or higher.

The substance/mixture does not contain components considered to have endocrine disrupting properties according to REACH Article 57(f) or Commission Delegated regulation (EU) 2017/2100 or Commission Regulation (EU) 2018/605 at levels of 0.1% or higher.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Treatment, storage, transportation, and disposal must be in accordance with applicable Federal, State/Provincial, and Local regulations.

Disposal

Dispose of packaging or containers in accordance with local, regional, national and international regulations.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Regulatory status for LUBRIZOL® MF9145D based on EU regulations and global inventory status.

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for LUBRIZOL® MF9145D?

The signal word is no signal word.

What is the physical form of LUBRIZOL® MF9145D?

LUBRIZOL® MF9145D is a liquid appearing as liquid with amber color. It has characteristic odor.

What is LUBRIZOL® MF9145D used for?

Miscellaneous fuel additive