Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Unleaded gasoline meeting EN228 (Oxygenated)
- Product Form
- Liquid
- Product Code
- STI2120
- Synonyms
- Gasoline in accordance with standard EN 228
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Use in fuel - Consumer (Benzene 0-1%) Use in fuel - Professional (Benzene 0-1%) Use in fuel - Industrial (Benzene 0-1%)
Uses advised against
NOT for aviation use. Should NOT be used as a solvent nor cleaning agent.
Manufacturers & Suppliers
BP Oil International
manufacturer
Chertsey Road, Sunbury on Thames, Middlesex, TW16 7BP, United Kingdom
Emergency Contacts
Emergency Contact
+44 (0)1865 407333
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS05
GHS07
GHS08
GHS09
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
A complex mixture of volatile hydrocarbons containing paraffins, naphthenes, olefins and aromatics with carbon numbers predominantly between C4 and C12. May contain oxygenates. May also contain small quantities of proprietary performance additives.
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Gasoline EC: 289-220-8 | 86290-81-5 | 80 - 100% | Yes |
| tert-butyl methyl ether EC: 216-653-1 | 1634-04-4 | 15% | Yes |
| 2-ethoxy-2-methylpropane (ETBE) EC: 211-309-7 | 637-92-3 | 15% | Yes |
| diisopropyl ether EC: 203-560-6 | 108-20-3 | 15% | Yes |
| Tertiary-amyl methyl ether (TAME) EC: 213-611-4 | 994-05-8 | 15% | Yes |
| 2-methylpropan-1-ol EC: 201-148-0 | 78-83-1 | 10% | Yes |
| Propan-2-ol EC: 200-661-7 | 67-63-0 | 10% | Yes |
| 2-methylpropan-2-ol EC: 200-889-7 | 75-65-0 | 7% | Yes |
| Ethanol EC: 200-578-6 | 64-17-5 | 5% | Yes |
| methanol EC: 200-659-6 | 67-56-1 | 3% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove to fresh air. Keep patient warm and at rest.
Symptoms: drowsiness, headache, blurred vision or irritation of the eyes, nose or throat
Immediately flush skin with plenty of water for at least 15 minutes while removing contaminated clothing and shoes. Drench contaminated clothing with water before removing. Contaminated leather, particularly footwear, must be discarded. Wash clothing before reuse. Clean shoes thoroughly before reuse.
Symptoms: Causes skin irritation. Prolonged or repeated contact can defat the skin and lead to irritation and/or dermatitis. Prolonged or repeated skin contact with methanol can also cause poisoning.
Immediately flush eyes with plenty of water for at least 15 minutes. Eyelids should be held away from the eyeball to ensure thorough rinsing. Check for and remove any contact lenses.
Symptoms: Causes serious eye damage. Vapour, mist or fume may cause eye irritation. Exposure to vapour, mist or fume may cause stinging, redness and watering of the eyes.
Never give anything by mouth to an unconscious person. If unconscious, place in recovery position.
Symptoms: Aspiration hazard if swallowed. Can enter lungs and cause damage.
Immediate Medical Attention
Get medical attention immediately.
Medical Treatment
Treatment should in general be symptomatic and directed to relieving any effects. Monitor for cardiac dysrhythmias. Gastric aspiration/lavage should be considered to prevent aspiration of vomit. Metabolic acidosis should be corrected. Metabolism of methanol may be blocked by administration of ethanol. Haemodialysis may be required in severe cases.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
In case of fire, use water fog, foam, dry chemical or carbon dioxide extinguisher or spray.
Do not use water jet. The use of a water jet may cause the fire to spread by splashing the burning product.
Extremely flammable liquid and vapour. In a fire or if heated, a pressure increase will occur and the container may burst, with the risk of a subsequent explosion. Runoff to sewer may create fire or explosion hazard. Vapours can form explosive mixtures with air. Vapours are heavier than air and can spread along the ground or float on water surfaces to remote ignition sources. Vapours may accumulate in low or confined areas or travel a considerable distance to a source of ignition and flash back. Liquid will float and may reignite on surface of water.
No action shall be taken involving any personal risk or without suitable training. Move containers from fire area if this can be done without risk. Use water spray to keep fire-exposed containers cool.
Firefighter Protection
Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Immediately contact emergency personnel. No action shall be taken involving any personal risk or without suitable training. Eliminate all ignition sources. Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilt material. Floors may be slippery; use care to avoid falling. No flares, smoking or flames in hazard area. Do not breathe vapour or mist. Provide adequate ventilation. Put on appropriate personal protective equipment.
In case of small spillages in closed waters (i.e. ports), contain product with floating barriers or other equipment.
If possible, large spillages in open waters should be contained with floating barriers or other mechanical means. If this is not possible, control the spreading of the spillage, and collect the product by skimming or other suitable mechanical means.
Avoid dispersal of spilt material and runoff and contact with soil, waterways, drains and sewers.
Collect spillage. Collect spilled product by absorbing with specific floating absorbents. If this is not possible, control the spreading of the spillage, and collect the product by skimming or other suitable mechanical means. The use of dispersants should be advised by an expert, and, if required, approved by local authorities.
Materials: specific floating absorbents
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Put on appropriate personal protective equipment. Avoid exposure - obtain special instructions before use. Avoid exposure during pregnancy. Do not handle until all safety precautions have been read and understood. Do not get in eyes or on skin or clothing. Do not breathe vapour or mist. Do not swallow. Aspiration hazard if swallowed. Can enter lungs and cause damage. Never siphon by mouth. Avoid contact of spilt material and runoff with soil and surface waterways. Use only with adequate ventilation. Wear appropriate respirator when ventilation is inadequate. Keep in the original container or an approved alternative made from a compatible material, kept tightly closed when not in use.
Keep in the original container or an approved alternative made from a compatible material, kept tightly closed when not in use. Store and use away from heat, sparks, open flame or any other ignition source.
Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Wash thoroughly after handling. Remove contaminated clothing and protective equipment before entering eating areas.
Store and use away from heat, sparks, open flame or any other ignition source. Use explosion-proof electrical (ventilating, lighting and material handling) equipment. Use only non-sparking tools. Take precautionary measures against electrostatic discharges.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Provide exhaust ventilation or other engineering controls to keep the relevant airborne concentrations below their respective occupational exposure limits.
Wear chemical resistant gloves. Do not re-use gloves. Protective gloves will deteriorate over time due to physical and chemical damage. Inspect and replace gloves on a regular basis. Protective gloves must give suitable protection against mechanical risks (i.e. abrasion, blade cut and puncture). Recommended: Nitrile gloves. The presence of aromatic hydrocarbons in the product will significantly shorten the length of time that nitrile gloves will provide protection. Do not re-use nitrile gloves if exposed to aromatic hydrocarbons. Gloves made from fluoroelastomer resistant to hydrocarbons and a wide range of chemicals. Wear a chemically resistant multi-layer laminate inner glove inside an outer nitrile glove. The purpose of the outer glove is to protect the inner glove from cuts and mechanical damage. Continuous contact: Gloves with a minimum breakthrough time of 240 minutes, or >480 minutes if suitable gloves can be obtained. Short-term / splash protection: Recommended breakthrough times as above. For general applications, we recommend gloves with a thickness typically greater than 0.35 mm. Refer to standards: Gloves: EN 420, EN 374.
Chemical splash goggles. Refer to standards: Eye protection: EN 166.
If local exhaust ventilation or other methods of ventilation are not possible or are insufficient, wear suitable respiratory protective devices. Wear suitable respiratory protective devices if there is a risk of exposure limits being exceeded. If required, the respiratory device must be certified as safe in defined explosive atmospheres (EX Label). Suitable breathing apparatus (independent of ambient atmosphere) must be worn if any of the following situations apply: When the workplace atmosphere is considered to be immediately dangerous to life and health; When there is a risk of the workplace atmosphere being oxygen deficient; When the workplace atmosphere is uncontrolled; When the workplace atmosphere is unknown; When there is a risk of loss of consciousness or asphyxiation; When entry into a confined space is required; When there is a risk of gases being released that could be a fire or explosion hazard; When the concentration of contaminants in the atmosphere exceeds the level of protection (maximum allowed concentration) given by a filtering device; When the contaminants have a low odour that would not be tasted or smelt by the wearer of a filtering device if the filter became exhausted or saturated; When there is a risk of hydrogen sulphide exposure limits being exceeded. Use with adequate ventilation. If there is a requirement for the use of a respiratory protective device, but the use of breathing apparatus (independent of ambient atmosphere) is not required, then a suitable filtering device must be worn. The filter class must be suitable for the maximum contaminant concentration (gas/vapour/aerosol/particulates) that may arise when handling the product. Recommended: Gas filter suitable for gases and vapours. Filter type: AX; Gas filter suitable for gases and vapours. Filter type: A; Combined filter suitable for gases, vapours and particles (dust, smoke, mist, aerosol). Filter type: AP. Refer to standards: Respiratory protection: EN 529, Filtering half-mask: EN 149, Filtering half-mask with valve: EN 405, Half-mask: EN 140 plus filter, Full-face mask: EN 136 plus filter, Particulate filters: EN 143, Gas/combined filters: EN 14387.
Wear suitable protective clothing. Footwear highly resistant to chemicals. When there is a risk of ignition wear inherently fire resistant protective clothes and gloves. Refer to standard: ISO 11612. When there is a risk of ignition from static electricity, wear anti-static protective clothing. For greatest effectiveness against static electricity, overalls, boots and gloves should all be anti-static. Refer to standard: EN 1149. Cotton or polyester/cotton overalls will only provide protection against light superficial contamination. When the risk of skin exposure is high (from experience this could apply to the following tasks: cleaning work, maintenance and service, filling and transfer, taking samples and cleaning up spillages) then a chemical protective suit and boots will be required. Work clothing / overalls should be laundered on a regular basis.
Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is stable.
No specific test data available for this product. Refer to Conditions to avoid and Incompatible materials for additional information.
Under normal conditions of storage and use, hazardous reactions will not occur. Under normal conditions of storage and use, hazardous polymerisation will not occur.
Avoid all possible sources of ignition (spark or flame). Do not pressurise, cut, weld, braze, solder, drill, grind or expose containers to heat or sources of ignition. Do not allow vapour to accumulate in low or confined areas.
Reactive or incompatible with the following materials: oxidising materials.
Under normal conditions of storage and use, hazardous decomposition products should not be produced.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.3 Bioaccumulative potential
12.3 Bioaccumulative potential
12.3 Bioaccumulative potential
12.1 Toxicity
12.2 Persistence and degradability
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
12.6 Endocrine disrupting properties
12.7 Other adverse effects
12.3 Bioaccumulative potential
12.3 Bioaccumulative potential
12.1 Toxicity
12.1 Toxicity
12.1 Toxicity
12.1 Toxicity
12.1 Toxicity
Toxic to aquatic life with long lasting effects.
12.2 Persistence and degradability
Expected to be biodegradable.
12.2 Persistence and degradability
12.2 Persistence and degradability
12.2 Persistence and degradability
12.2 Persistence and degradability
12.2 Persistence and degradability
12.2 Persistence and degradability
12.2 Persistence and degradability
12.3 Bioaccumulative potential
This product is not expected to bioaccumulate through food chains in the environment.
12.3 Bioaccumulative potential
12.3 Bioaccumulative potential
12.3 Bioaccumulative potential
12.3 Bioaccumulative potential
12.3 Bioaccumulative potential
12.4 Mobility in soil
The soil/water partition coefficient (Koc) is not available. Spillages may penetrate the soil causing ground water contamination.
12.5 Results of PBT and vPvB assessment
The product does not meet the criteria for PBT or vPvB according to Regulation (EC) No. 1907/2006, Annex XIII.
12.6 Other adverse effects
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Where possible, arrange for product to be recycled. Dispose of via an authorised person/licensed waste disposal contractor in accordance with local regulations.
Where possible, arrange for product to be recycled. Dispose of via an authorised person/licensed waste disposal contractor in accordance with local regulations.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN1203
- Shipping Name
- BASOLINE or MOTOR SPIRIT
- Transport Class
- 3
- Packing Group
- II
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The company, as identified in Section 1, sells this product in the EU in compliance with the current requirements of REACH.
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is Unleaded gasoline meeting EN228 (Oxygenated) known by?
Unleaded gasoline meeting EN228 (Oxygenated) is also known as: Gasoline in accordance with standard EN 228
What is the hazard signal word for Unleaded gasoline meeting EN228 (Oxygenated)?
The signal word is danger.
What is the physical form of Unleaded gasoline meeting EN228 (Oxygenated)?
Unleaded gasoline meeting EN228 (Oxygenated) is a liquid. with colourless to light yellow. color. It has petrol odor.
What is the solubility of Unleaded gasoline meeting EN228 (Oxygenated)?
Partially soluble in water (Gasoline: Very slightly soluble in water)
What is Unleaded gasoline meeting EN228 (Oxygenated) used for?
Use in fuel - Consumer (Benzene 0-1%) Use in fuel - Professional (Benzene 0-1%) Use in fuel - Industrial (Benzene 0-1%)
What are the hazard statements for Unleaded gasoline meeting EN228 (Oxygenated)?
This substance has 10 hazard statements:
- H224: Extremely flammable liquid and vapour.
- H304: May be fatal if swallowed and enters airways.
- H315: Causes skin irritation.
- H318: Causes serious eye damage.
- H336: May cause drowsiness or dizziness.
- H340: May cause genetic defects.
- H350: May cause cancer.
- H361f: Suspected of damaging fertility. Suspected of damaging the unborn child.
- H371: May cause damage to organs.
- H411: Toxic to aquatic life with long lasting effects.
What is the melting point of Unleaded gasoline meeting EN228 (Oxygenated)?
The melting point is <-60°C (<-76°F) (Based on Petrol) and the boiling point is 30 to 210°C (86 to 410°F).