NextSDS Logo
Safety Data Sheet EN

ACRYSOL™ RM-8 Rheology Modifier

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
ACRYSOL™ RM-8 Rheology Modifier

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Coatings product

Manufacturers & Suppliers

D

DOW BENELUX B.V.

manufacturer

HERBERT H.DOWWEG 5 HOEK 4542 NM TERNEUZEN NETHERLANDS

(31) 115 67 2626

Emergency Contacts

Emergency Contact

31-(0)115 694982

Emergency Contact

00 32 3575 0330

Belgium Poison Center

070/245.245

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Polyurethane resin water based

Chemical Name CAS Number Concentration Hazardous
Propane-1,2-diol EC: 200-338-0 57-55-6 36 - 38% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move person to fresh air and keep comfortable for breathing; consult a physician.

Skin contact

Wash off with plenty of water.

Eye contact

Flush eyes thoroughly with water for several minutes. Remove contact lenses after the initial 1-2 minutes and continue flushing for several additional minutes. If effects occur, consult a physician, preferably an ophthalmologist.

Ingestion

Rinse mouth with water. No emergency medical treatment necessary.

Medical Treatment

Treatment of exposure should be directed at the control of symptoms and the clinical condition of the patient.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Alcohol-resistant foam. Carbon dioxide (CO2). Dry chemical. Water spray.

Unsuitable media

None known..

Specific hazards

Exposure to combustion products may be a hazard to health.

Instructions

Remove undamaged containers from fire area if it is safe to do so.

Firefighter Protection

Wear self-contained breathing apparatus for firefighting if necessary. Use personal protective equipment.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Follow safe handling advice and personal protective equipment recommendations.

Large spill

For large spills, provide dyking or other appropriate containment to keep material from spreading. If dyked material can be pumped, store recovered material in appropriate container.

Environmental

Discharge into the environment must be avoided. Prevent further leakage or spillage if safe to do so. Prevent spreading over a wide area (e.g. by containment or oil barriers). Retain and dispose of contaminated wash water.

Cleanup methods

Soak up with inert absorbent material. Clean up remaining materials from spill with suitable absorbant.

Materials: inert absorbent material

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Take care to prevent spills, waste and minimize release to the environment. Handle in accordance with good industrial hygiene and safety practice.

Storage

Keep in properly labelled containers. Store in accordance with the particular national regulations.

Hygiene

Handle in accordance with good industrial hygiene and safety practice.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Use local exhaust ventilation, or other engineering controls to maintain airborne levels below exposure limit requirements or guidelines. If there are no applicable exposure limit requirements or guidelines, general ventilation should be sufficient for most operations. Local exhaust ventilation may be necessary for some operations.

Hands

Use gloves chemically resistant to this material when prolonged or frequently repeated contact could occur. Use chemical resistant gloves classified under Standard EN374: Protective gloves against chemicals and micro-organisms. Examples of preferred glove barrier materials include: Butyl rubber. Natural rubber ("latex"). Nitrile/butadiene rubber ("nitrile" or "NBR"). Polyethylene. Ethyl vinyl alcohol laminate ("EVAL"). Polyvinyl chloride ("PVC" or "vinyl"). Examples of acceptable glove barrier materials include: Neoprene. Avoid gloves made of: Polyvinyl alcohol ("PVA"). When prolonged or frequently repeated contact may occur, a glove with a protection class of 3 or higher (breakthrough time greater than 60 minutes according to EN 374) is recommended. Glove thickness alone is not a good indicator of the level of protection a glove provides against a chemical substance as this level of protection is also highly dependent on the specific composition of the material that the glove is fabricated from. The thickness of the glove must, depending on model and type of material, generally be more than 0.35 mm to offer sufficient protection for prolonged and frequent contact with the substance. As an exception to this general rule it is known that multilayer laminate gloves may offer prolonged protection at thicknesses less than 0.35 mm. Other glove materials with a thickness of less than 0.35 mm may offer sufficient protection when only brief contact is expected. NOTICE: The selection of a specific glove for a particular application and duration of use in a workplace should also take into account all relevant workplace factors such as, but not limited to: Other chemicals which may be handled, physical requirements (cut/puncture protection, dexterity, thermal protection), potential body reactions to glove materials, as well as the instructions/specifications provided by the glove supplier.

Eyes

Use safety glasses (with side shields). Safety glasses (with side shields) should be consistent with EN 166 or equivalent.

Respiratory

Respiratory protection should be worn when there is a potential to exceed the exposure limit requirements or guidelines. If there are no applicable exposure limit requirements or guidelines, wear respiratory protection when adverse effects, such as respiratory irritation or discomfort have been experienced, or where indicated by your risk assessment process. In misty atmospheres, use an approved particulate respirator. Use the following CE approved air-purifying respirator: Organic vapor cartridge with a particulate pre-filter, type AP2 (meeting standard EN 14387).

Skin/Body

Wear clean, body-covering clothing.

Environmental

See SECTION 7: Handling and storage and SECTION 13: Disposal considerations for measures to prevent excessive environmental exposure during use and waste disposal.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
Clear to cloudy
Colour
Clear to cloudy
Colour Intensity
---
Form
---
Odor
Mild odor
Odor Threshold
---
Ph
8,0 - 9,0
Melting Point
No data available.
Boiling Point
100,00 °C Water
Flash Point
110,00 °C _SETAFLASH CLOSED CUP_
Freezing Point
not determined
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
<1,00 Water = 1
Vapor Pressure
not determined
Vapor Density
---
Relative Density
1,0000 - 1,2000
Bulk Density
---
Density
---
Flammability
Not applicable, liquid
Upper Explosive Limit
12,50 % vol estimated
Lower Explosive Limit
2,60 % vol estimated
Explosive Limits
---
Auto Ignition Temperature
421,00 °C estimated
Decomposition Temperature
not determined
Solubility
---
Partition Coefficient
not determined
Solubility In Water
completely soluble
Solubility In Fat
---
Molecular Weight
not determined
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
60 000,000 mPa.s maximum
Kinematic Viscosity
not determined
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

Not classified as a reactivity hazard.

Hazardous reactions

Can react with strong oxidizing agents.

Avoid

None known.

Incompatible

Avoid contact with oxidizing materials.

Decomposition

No hazardous decomposition products are known.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Toxicity

Material is not classified as dangerous to aquatic organisms (LC50/EC50/IC50/LL50/EL50 greater than 100 mg/L in most sensitive species). For this family of materials: LC50, Rainbow trout (Oncorhynchus mykiss), 96 Hour, 741 mg/l, OECD Test Guideline 203

12.1 Toxicity

For this family of materials: EC50, Daphnia magna, 48 Hour, 897 mg/l, OECD Test Guideline 202 For this family of materials: NOEC, Daphnia magna, 48 Hour, 563 mg/l, OECD Test Guideline 202

12.1 Toxicity

Acute toxicity to algae/aquatic plants For this family of materials: EbC50, green alga Pseudokirchneriella subcapitata (formerly known as Selenastrum capricornutum), Static, 72 Hour, Biomass, 229 mg/l, OECD Test Guideline 201 For this family of materials: NOEC, green alga Pseudokirchneriella subcapitata (formerly known as Selenastrum capricornutum), Static, 72 Hour, 125 mg/l, OECD Test Guideline 201

12.2 Persistence and degradability

Biodegradability: Material is expected to biodegrade very slowly (in the environment). Fails to pass OECD/EEC tests for ready biodegradability.

Material is expected to biodegrade very slowly and fails to pass OECD/EEC tests for ready biodegradability.

12.3 Bioaccumulative potential

12.3 Bioaccumulative potential

Bioaccumulation: Bioconcentration potential is low (BCF < 100 or Log Pow < 3). Partition coefficient: n-octanol/water(log Pow): -1,07 Measured Bioconcentration factor (BCF): 0,09 Fish Estimated.

12.4 Mobility in soil

Given its very low Henry's constant, volatilization from natural bodies of water or moist soil is not expected to be an important fate process. Partition coefficient (Koc): < 1 Estimated.

12.5 Results of PBT and vPvB assessment

This mixture has not been assessed for persistence, bioaccumulation and toxicity (PBT).

12.6 Endocrine disrupting properties

The substance/mixture does not contain components considered to have endocrine disrupting properties according to REACH Article 57(f) or Commission Delegated regulation (EU) 2017/2100 or Commission Regulation (EU) 2018/605 at levels of 0.1% or higher. The substance is not considered to have endocrine disrupting properties according to REACH Article 57(f), Commission Regulation (EU) 2018/605 or Commission Delegated Regulation (EU) 2017/2100.

12.7 Other adverse effects

No relevant data found.
13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

For uncontaminated material the disposal options include mechanical and chemical recycling or energy recovery. In some countries landfill is also allowed. For contaminated material the options remain the same, although additional evaluation is required.

Disposal

Contact the authorized waste disposal services.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

This product contains only components that have been either registered, are exempt from registration, are regarded as registered or are not subject to registration according to Regulation (EC) No. 1907/2006 (REACH). Polymers are exempted from registration under REACH. All relevant starting materials and additives have been either registered or are exempt from registration according to Regulation (EC) No. 1907/2006 (REACH).

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for ACRYSOL™ RM-8 Rheology Modifier?

The signal word is no signal word.

What is the physical form of ACRYSOL™ RM-8 Rheology Modifier?

ACRYSOL™ RM-8 Rheology Modifier is a liquid appearing as clear to cloudy with clear to cloudy color. It has mild odor odor.

What is ACRYSOL™ RM-8 Rheology Modifier used for?

Coatings product

What is the melting point of ACRYSOL™ RM-8 Rheology Modifier?

The melting point is No data available. and the boiling point is 100,00 °C Water.