Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Synfluid® PAO 8 cSt
- Product Code
- 1111743, 1111742, 1111735, 1079836, 1079942, 1079666
- Chemical Name
- 1-Decene
Regulatory Identifiers
- CAS Number
- 872-05-9 Check regulations →
- EC Number
- 212-819-2 Check regulations →
- REACH No.
- 01-2119486878-12-0006
Identified Uses
Manufacture Use as an intermediate Formulation Use in coatings – industrial Use in coatings – professional Use in Coatings - Consumer Lubricants - Industrial Lubricants - Professional Lubricants - Consumer Metal working fluids / rolling oils - Industrial Metal working fluids / rolling oils – Professional Functional Fluids - Industrial Functional Fluids - Professional Functional Fluids - Consumer Use in polymer production – industrial Agrochemical uses Agrochemical uses Other consumer uses
Uses advised against
This material should not be used for purposes other than the identified uses in section 1 without expert advice.
Manufacturers & Suppliers
Chevron Phillips Chemical Company LP
manufacturer
9500 Lakeside Blvd., The Woodlands, TX 77381
Chevron Phillips Chemicals International N.V.
local supplier
Airport Plaza (Stockholm Building), Leonardo Da Vincilaan 19, 1831 Diegem, Belgium
(800) 852-5530
http://www.CPChem.com
Emergency Contacts
Emergency Contact
866.442.9628
Emergency Contact
1.832.813.4984
CHEMTREC
800.424.9300
CHEMTREC
703.527.3887
CHEMWATCH
+612 9186 1132
Emergency Contact
0532 8388 9090
CHEMTREC
01-800-681-9531
24 hours
SOS-Cotec
0800.111.767
SOS-Cotec
+55.19.3467.1600
Emergency Contact
+(54)-1159839431
BIG
+32.14.584545
BIG
+32.14583516
VIZ
+43 1 406 43 43
24 hours/day, 7 days/week
Emergency Contact
070 245 245
24 hours/day, 7 days/week
Emergency Contact
+359 2 9154 233
Emergency Contact
+3851 2348 342
24 hours/day, 7 days/week
Emergency Contact
1401
Toxicological Information Center
+420 224 919 293
Toxicological Information Center
+420 224 915 402
Danish Poison Center (Giftlinjen)
+45 8212 1212
BIG
+32.14.584545
BIG
+32.14583516
Emergency Contact
0800 147 111
24 hours/day
Emergency Contact
09 471 977
24 hours/day
ORFILA number (INRS)
+33 (0) 1 45 42 59 59
24 hours/day, 7 days/week
BIG
+32.14.584545
BIG
+32.14583516
Emergency Contact
(0030) 2107793777
24 hours/day, 7 days/week
Emergency Contact
+36-80-201-199
24 hours/day, 7 days/week
Emergency Contact
543 2222
24 hours/day, 7 days/week
BIG
+32.14.584545
BIG
+32.14583516
POISON CENTER MILAN
+39 02 66101029
POISON CENTER ROME
+39 06 3054343
POISON CENTER ROME
+39 06 68593726
POISON CENTER ROME
+39 06 4997 8000
POISON CENTER FOGGIA
+39 0881 732326
POISON CENTER NAPLES
+39 081 7472870
POISON CENTER FLORENCE
+39 055 7947819
POISON CENTER PAVIA
+39 0382 24444
POISON CENTER BERGAMO
800 883 300
POISON CENTER VERONA
800 011 858
Emergency Contact
112
Toxicology and Sepsis Clinic Poisoning and Drug Information Center
+371 67042473
24 hours
BIG
+32.14.584545
BIG
+32.14583516
Emergency Contact
+370 (85) 2362052
Emergency Contact
(+352) 8002 5500
24 hours/day, 7 days/week
Emergency Contact
+356 2395 2000
NVIC
+31 (0)88 755 8000
Emergency Contact
22 59 13 00
24 hours/day, 7 days/week
BIG
+32.14.584545
BIG
+32.14583516
CIAV
+351 800 250 250
Emergency Contact
+40213183606
Emergency Contact
+421 2 5477 4166
Emergency Contact
112
National Emergency Telephone Number of Spanish Poison Centre
+34 91 562 04 20
24 hours/day, 7 days/week
Emergency Contact
112
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Synonyms : Polyalphaolefin PAO Molecular formula : Polymer
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| 1-Decene Homopolymer Hydrogenated | --- | 100% | No |
Notes
Contains no ingredients hazardous to health according to GHS.
First Aid Measures
Emergency procedures for chemical exposure incidents
If unconscious, place in recovery position and seek medical advice. If symptoms persist, call a physician.
Remove contact lenses. Protect unharmed eye. If eye irritation persists, consult a specialist.
Keep respiratory tract clear. Never give anything by mouth to an unconscious person. If symptoms persist, call a physician.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.
High volume water jet.
Standard procedure for chemical fires.
Standard procedure for chemical fires.
Firefighter Protection
Wear self-contained breathing apparatus for firefighting if necessary.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Use personal protective equipment. Ensure adequate ventilation. Evacuate personnel to safe areas. Material can create slippery conditions.
No special environmental precautions required.
Wipe up with absorbent material (e.g. cloth, fleece).
Materials: cloth, fleece
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
For personal protection see section 8. Smoking, eating and drinking should be prohibited in the application area.
Electrical installations / working materials must comply with the technological safety standards.
Smoking, eating and drinking should be prohibited in the application area.
Normal measures for preventive fire protection.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Adequate ventilation to control airborne concentrations below the exposure guidelines/limits. Consider the potential hazards of this material (see Section 2), applicable exposure limits, job activities, and other substances in the work place when designing engineering controls and selecting personal protective equipment. If engineering controls or work practices are not adequate to prevent exposure to harmful levels of this material, the personal protective equipment listed below is recommended. The user should read and understand all instructions and limitations supplied with the equipment since protection is usually provided for a limited time or under certain circumstances.
The suitability for a specific workplace should be discussed with the producers of the protective gloves. Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. Also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion, and the contact time. Gloves should be discarded and replaced if there is any indication of degradation or chemical breakthrough.
Eye wash bottle with pure water. Tightly fitting safety goggles.
If ventilation or other engineering controls are not adequate to maintain minimal oxygen content of 19.5% by volume under normal atmospheric pressure, a supplied-air NIOSH approved respirator may be appropriate.
Choose body protection according to the amount and concentration of the substance and the task performed at the work place. Appropriate PPE may include: Lightweight protective clothing.
A quantitative risk assessment is not required for the environment.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
This material is considered stable under normal ambient and anticipated storage and handling conditions of temperature and pressure.
Stable at normal ambient temperature and pressure.
No hazards to be specially mentioned.
No data available.
No data available.
No data available.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
12.2 Persistence and degradability
12.3 Bioaccumulative potential
12.4 Mobility in soil
Results of PBT and vPvB assessment
The substance/mixture contains no components considered to be either persistent, bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at levels of 0.1% or higher.
Endocrine disrupting properties
The substance/mixture does not contain components considered to have endocrine disrupting properties according to REACH Article 57(f) or Commission Delegated regulation (EU) 2017/2100 or Commission Regulation (EU) 2018/605 at levels of 0.1% or higher.
12.7 Other adverse effects
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Use material for its intended purpose or recycle if possible.
This material, if it must be discarded, may meet the criteria of a hazardous waste as defined by US EPA under RCRA (40 CFR 261) or other State and local regulations. Measurement of certain physical properties and analysis for regulated components may be necessary to make a correct determination. If this material is classified as a hazardous waste, federal law requires disposal at a licensed hazardous waste disposal facility.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Commission Regulation (EU) 2020/878 of 18 June 2020 amending Regulation (EC) No 1907/2006 of the European Parliament and of the Council on the Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH)
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Synfluid® PAO 8 cSt?
The signal word is no signal word.
What is the physical form of Synfluid® PAO 8 cSt?
Synfluid® PAO 8 cSt is a liquid appearing as clear, colorless with clear, colorless color. It has odorless odor.
What is Synfluid® PAO 8 cSt used for?
Manufacture Use as an intermediate Formulation Use in coatings – industrial Use in coatings – professional Use in Coatings - Consumer Lubricants - Industrial Lubricants - Professional Lubricants - Consumer Metal working fluids / rolling oils - Industrial Metal working fluids / rolling oils – Professional Functional Fluids - Industrial Functional Fluids - Professional Functional Fluids - Consumer Use in polymer production – industrial Agrochemical uses Agrochemical uses Other consumer uses
What is the melting point of Synfluid® PAO 8 cSt?
The melting point is Not applicable and the boiling point is 430°C (806°F).