NextSDS Logo
Safety Data Sheet EN

Synfluid® PAO 8 cSt

CAS 872-05-9
EC 212-819-2

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Synfluid® PAO 8 cSt
Product Code
1111743, 1111742, 1111735, 1079836, 1079942, 1079666
Chemical Name
1-Decene

Regulatory Identifiers

CAS Number
872-05-9 Check regulations →
EC Number
212-819-2 Check regulations →
REACH No.
01-2119486878-12-0006

Identified Uses

Manufacture Use as an intermediate Formulation Use in coatings – industrial Use in coatings – professional Use in Coatings - Consumer Lubricants - Industrial Lubricants - Professional Lubricants - Consumer Metal working fluids / rolling oils - Industrial Metal working fluids / rolling oils – Professional Functional Fluids - Industrial Functional Fluids - Professional Functional Fluids - Consumer Use in polymer production – industrial Agrochemical uses Agrochemical uses Other consumer uses

Uses advised against

This material should not be used for purposes other than the identified uses in section 1 without expert advice.

Manufacturers & Suppliers

C

Chevron Phillips Chemical Company LP

manufacturer

9500 Lakeside Blvd., The Woodlands, TX 77381

Chevron Phillips Chemicals International N.V. logo

Chevron Phillips Chemicals International N.V.

local supplier

Airport Plaza (Stockholm Building), Leonardo Da Vincilaan 19, 1831 Diegem, Belgium

(800) 852-5530

http://www.CPChem.com

Emergency Contacts

Emergency Contact

866.442.9628

Emergency Contact

1.832.813.4984

CHEMTREC

800.424.9300

CHEMTREC

703.527.3887

CHEMWATCH

+612 9186 1132

Emergency Contact

0532 8388 9090

CHEMTREC

01-800-681-9531

24 hours

SOS-Cotec

0800.111.767

SOS-Cotec

+55.19.3467.1600

Emergency Contact

+(54)-1159839431

BIG

+32.14.584545

BIG

+32.14583516

VIZ

+43 1 406 43 43

24 hours/day, 7 days/week

Emergency Contact

070 245 245

24 hours/day, 7 days/week

Emergency Contact

+359 2 9154 233

Emergency Contact

+3851 2348 342

24 hours/day, 7 days/week

Emergency Contact

1401

Toxicological Information Center

+420 224 919 293

Toxicological Information Center

+420 224 915 402

Danish Poison Center (Giftlinjen)

+45 8212 1212

BIG

+32.14.584545

BIG

+32.14583516

Emergency Contact

0800 147 111

24 hours/day

Emergency Contact

09 471 977

24 hours/day

ORFILA number (INRS)

+33 (0) 1 45 42 59 59

24 hours/day, 7 days/week

BIG

+32.14.584545

BIG

+32.14583516

Emergency Contact

(0030) 2107793777

24 hours/day, 7 days/week

Emergency Contact

+36-80-201-199

24 hours/day, 7 days/week

Emergency Contact

543 2222

24 hours/day, 7 days/week

BIG

+32.14.584545

BIG

+32.14583516

POISON CENTER MILAN

+39 02 66101029

POISON CENTER ROME

+39 06 3054343

POISON CENTER ROME

+39 06 68593726

POISON CENTER ROME

+39 06 4997 8000

POISON CENTER FOGGIA

+39 0881 732326

POISON CENTER NAPLES

+39 081 7472870

POISON CENTER FLORENCE

+39 055 7947819

POISON CENTER PAVIA

+39 0382 24444

POISON CENTER BERGAMO

800 883 300

POISON CENTER VERONA

800 011 858

Emergency Contact

112

Toxicology and Sepsis Clinic Poisoning and Drug Information Center

+371 67042473

24 hours

BIG

+32.14.584545

BIG

+32.14583516

Emergency Contact

+370 (85) 2362052

Emergency Contact

(+352) 8002 5500

24 hours/day, 7 days/week

Emergency Contact

+356 2395 2000

NVIC

+31 (0)88 755 8000

Emergency Contact

22 59 13 00

24 hours/day, 7 days/week

BIG

+32.14.584545

BIG

+32.14583516

CIAV

+351 800 250 250

Emergency Contact

+40213183606

Emergency Contact

+421 2 5477 4166

Emergency Contact

112

National Emergency Telephone Number of Spanish Poison Centre

+34 91 562 04 20

24 hours/day, 7 days/week

Emergency Contact

112

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance

Synonyms : Polyalphaolefin PAO Molecular formula : Polymer

Chemical Name CAS Number Concentration Hazardous
1-Decene Homopolymer Hydrogenated --- 100% No

Notes

Contains no ingredients hazardous to health according to GHS.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

If unconscious, place in recovery position and seek medical advice. If symptoms persist, call a physician.

Eye contact

Remove contact lenses. Protect unharmed eye. If eye irritation persists, consult a specialist.

Ingestion

Keep respiratory tract clear. Never give anything by mouth to an unconscious person. If symptoms persist, call a physician.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.

Unsuitable media

High volume water jet.

Specific hazards

Standard procedure for chemical fires.

Instructions

Standard procedure for chemical fires.

Firefighter Protection

Wear self-contained breathing apparatus for firefighting if necessary.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Use personal protective equipment. Ensure adequate ventilation. Evacuate personnel to safe areas. Material can create slippery conditions.

Environmental

No special environmental precautions required.

Cleanup methods

Wipe up with absorbent material (e.g. cloth, fleece).

Materials: cloth, fleece

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

For personal protection see section 8. Smoking, eating and drinking should be prohibited in the application area.

Storage

Electrical installations / working materials must comply with the technological safety standards.

Hygiene

Smoking, eating and drinking should be prohibited in the application area.

Fire prevention

Normal measures for preventive fire protection.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Adequate ventilation to control airborne concentrations below the exposure guidelines/limits. Consider the potential hazards of this material (see Section 2), applicable exposure limits, job activities, and other substances in the work place when designing engineering controls and selecting personal protective equipment. If engineering controls or work practices are not adequate to prevent exposure to harmful levels of this material, the personal protective equipment listed below is recommended. The user should read and understand all instructions and limitations supplied with the equipment since protection is usually provided for a limited time or under certain circumstances.

Hands

The suitability for a specific workplace should be discussed with the producers of the protective gloves. Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. Also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion, and the contact time. Gloves should be discarded and replaced if there is any indication of degradation or chemical breakthrough.

Eyes

Eye wash bottle with pure water. Tightly fitting safety goggles.

Respiratory

If ventilation or other engineering controls are not adequate to maintain minimal oxygen content of 19.5% by volume under normal atmospheric pressure, a supplied-air NIOSH approved respirator may be appropriate.

Skin/Body

Choose body protection according to the amount and concentration of the substance and the task performed at the work place. Appropriate PPE may include: Lightweight protective clothing.

Environmental

A quantitative risk assessment is not required for the environment.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
Clear, Colorless
Colour
Clear, Colorless
Colour Intensity
---
Form
---
Odor
Odorless
Odor Threshold
---
Ph
Not applicable
Melting Point
Not applicable
Boiling Point
430°C (806°F)
Flash Point
252-265°C (486-509°F) Method: ASTM D-92
Freezing Point
Not applicable
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
3 Method: ASTM D5800
Vapor Pressure
0,10 MMHG at 232°C (450°F)
Vapor Density
---
Relative Density
0,83 at 15,6 °C (60,1 °F)
Bulk Density
---
Density
---
Flammability
---
Upper Explosive Limit
Not applicable
Lower Explosive Limit
Not applicable
Explosive Limits
---
Auto Ignition Temperature
369°C (696°F)
Decomposition Temperature
No data available
Solubility
---
Partition Coefficient
---
Solubility In Water
insoluble in water
Solubility In Fat
---
Molecular Weight
Varies
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
46 cSt at 40°C (104°F)
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

This material is considered stable under normal ambient and anticipated storage and handling conditions of temperature and pressure.

Reactivity

Stable at normal ambient temperature and pressure.

Hazardous reactions

No hazards to be specially mentioned.

Avoid

No data available.

Incompatible

No data available.

Decomposition

No data available.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Toxicity

Ecotoxicity effects Toxicity to fish : LL50: > 1.000 mg/l Exposure time: 96 h Species: Oncorhynchus mykiss (rainbow trout) Toxicity to daphnia and other aquatic invertebrates : EL50: > 1.000 mg/l Exposure time: 48 h Species: Daphnia magna (Water flea) static test Method: OECD Test Guideline 202 Toxicity to algae : NOELR: 1.000 mg/l Exposure time: 72 h Species: Scenedesmus capricornutum (fresh water algae) static test Method: OECD Test Guideline 201

12.2 Persistence and degradability

Biodegradability : This material is not expected to be readily biodegradable. Expected to be inherently biodegradable.

12.3 Bioaccumulative potential

Elimination information (persistence and degradability) Bioaccumulation : This material is not expected to bioaccumulate.

12.4 Mobility in soil

Mobility : No data available

Results of PBT and vPvB assessment

Results of PBT assessment : This substance/mixture contains no components considered to be either persistent, bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at levels of 0.1% or higher.

The substance/mixture contains no components considered to be either persistent, bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at levels of 0.1% or higher.

Endocrine disrupting properties

Endocrine disrupting properties : The substance/mixture does not contain components considered to have endocrine disrupting properties according to REACH Article 57(f) or Commission Delegated regulation (EU) 2017/2100 or Commission Regulation (EU) 2018/605 at levels of 0.1% or higher.

The substance/mixture does not contain components considered to have endocrine disrupting properties according to REACH Article 57(f) or Commission Delegated regulation (EU) 2017/2100 or Commission Regulation (EU) 2018/605 at levels of 0.1% or higher.

12.7 Other adverse effects

No data available
13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Use material for its intended purpose or recycle if possible.

Disposal

This material, if it must be discarded, may meet the criteria of a hazardous waste as defined by US EPA under RCRA (40 CFR 261) or other State and local regulations. Measurement of certain physical properties and analysis for regulated components may be necessary to make a correct determination. If this material is classified as a hazardous waste, federal law requires disposal at a licensed hazardous waste disposal facility.

Waste Codes

40 CFR 261 Criteria for hazardous waste RCRA
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Commission Regulation (EU) 2020/878 of 18 June 2020 amending Regulation (EC) No 1907/2006 of the European Parliament and of the Council on the Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH)

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Synfluid® PAO 8 cSt?

The signal word is no signal word.

What is the physical form of Synfluid® PAO 8 cSt?

Synfluid® PAO 8 cSt is a liquid appearing as clear, colorless with clear, colorless color. It has odorless odor.

What is Synfluid® PAO 8 cSt used for?

Manufacture Use as an intermediate Formulation Use in coatings – industrial Use in coatings – professional Use in Coatings - Consumer Lubricants - Industrial Lubricants - Professional Lubricants - Consumer Metal working fluids / rolling oils - Industrial Metal working fluids / rolling oils – Professional Functional Fluids - Industrial Functional Fluids - Professional Functional Fluids - Consumer Use in polymer production – industrial Agrochemical uses Agrochemical uses Other consumer uses

What is the melting point of Synfluid® PAO 8 cSt?

The melting point is Not applicable and the boiling point is 430°C (806°F).