NextSDS Logo
Safety Data Sheet EN

Q8 Antifreeze Long Life OAT

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Q8 Antifreeze Long Life OAT

Regulatory Identifiers

CAS Number
N/A
UFI Code
YV60-M0RQ-K00U-R75H

Identified Uses

Antifreeze and coolant for engines and industrial equipment

Manufacturers & Suppliers

K

Kuwait Petroleum Companies in the Benelux

national supplier

Brusselstraat 59, 2018 Antwerp, Belgium

+32 3 247 38 11

K

Kuwait Petroleum Belgium N.V./S.A.

manufacturer

Petroleumkaai 7, B-2020 Antwerp, Belgium

Q

Q8Oils Italia S.r.l.

manufacturer

Via Volpedo 2, 15050 Castellar Guidobono (AL), Italy

Emergency Contacts

CARECHEM24

+44 (0) 1235 239 670

CARECHEM24

+44 (0) 1865 407 333

Poisons Information Centre

+43 1 406 43 43

Poison Centre

+32 (0)70 245 245

National Toxicology Centre

+359 (0)2 9154 233

Poison Control Centre

+385 (0)1 23-48-342

Poison Centre

1401

Toxicological Information Centre

+420 224 919 293

Toxicological Information Centre

+420 224 915 402

Bispebjerg Hospital - poison line

+45 8212 1212

Emergency Contact

112

Poison Information Centre, Health Board

16662

Poison Information Centre, Health Board

+372 7943 794

Emergency Contact

112

Poison Information Center

+358 (0)9 471 977

Poison Control Centre (ORFILA)

+33 (0)1 45 42 59 59

Emergency Poison Centre telephone number, Aglaia Kyriakou Children's Hospital

+30 210 779 3777

Health Toxicological Information Service

+36 (06) 80 201-199

Poison Information Centre

+354 543 2222

NPIC Beaumont Hospital

+353 (0)1 809 2166

8am-10pm, 7 days a week

CAV "Osp. Pediatrico Bambino Gesù" Dip. Emergenza e Accettazione DEA (ROMA)

06 68593726

Az. Osp. Univ. Foggia (FOGGIA)

800183459

Az. Osp. "A. Cardarelli" (NAPOLI)

081-5453333

CAV Policlinico "Umberto I" (ROMA)

06-49978000

CAV Policlinico "A. Gemelli" (ROMA)

06-3054343

Az. Osp. "Careggi" U.O. Tossicologia Medica (FIRENZE)

055-7947819

CAV Centro Nazionale di Informazione Tossicologica (PAVIA)

0382-24444

Osp. Niguarda Ca' Granda (MILANO)

02-66101029

Azienda Ospedaliera Papa Giovanni XXII (BERGAMO)

800883300

Azienda Ospedaliera Integrata Verona (VERONA)

800011858

State Fire and Rescue Service

112

State Toxicology Center, Poisoning and Drug Information Center

+371 67042473

Tox InfoSuisse

145

Tox InfoSuisse

+41 44 251 51 51

Emergency Contact

112

Poison Information Office

+370 (8)5 236 20 52

Poison Information Office

+370 (8)6 875 33 78

Belgian Poison Centre

8002 5500

Emergency Contact

112

Poison Centre

+356 2545 6504

Nationaal Vergiftigingen Informatie Centrum, Utrecht

+31 (0)88 755 8000

Poison Centre

+47 22 59 13 00

Poison Information Centre

+351 800 250 250

National Institute of Public Health

+40 (0)21 318 36 06

08:00 - 15:00

National Toxicological Information Centre

+421 (0)2 54 774 166

Emergency Contact

112

Toxicological Information Service

+34 91 562 04 20

Emergency Contact

112

Tox Info Suisse

145

Tox Info Suisse

+41 44 251 51 51

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Acute Tox. Cat. 4 H302
STOT RE Cat. 2 H373

GHS Pictograms

GHS07 - Health hazard

GHS07

GHS08 - Serious health hazard

GHS08

Hazard Statements

H302 Harmful if swallowed.
H373 May cause damage to organs through prolonged or repeated exposure.

Precautionary Statements

P101 If medical advice is needed, have product container or label at hand.
P102 Keep out of reach of children.
P103 Read carefully and follow all instructions.
P260 Do not breathe vapor.
P264 Wash thoroughly after handling.
P270 Do not eat, drink or smoke when using this product.
P301 + P310 IF SWALLOWED: Immediately call a POISON CENTER or doctor.
P501 Dispose of contents and container in accordance with all local, regional, national and international regulations.

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
ethanediol EC: 203-473-3 107-21-1 90% Yes
sodium benzoate EC: 208-534-8 532-32-1 5% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove victim to fresh air and keep at rest in a position comfortable for breathing. If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel. It may be dangerous to the person providing aid to give mouth-to-mouth resuscitation. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.

Skin contact

Flush contaminated skin with plenty of water. Remove contaminated clothing and shoes. Continue to rinse for at least 10 minutes. Wash clothing before reuse. Clean shoes thoroughly before reuse.

Eye contact

Immediately flush eyes with plenty of water, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Continue to rinse for at least 10 minutes.

Ingestion

Wash out mouth with water. Remove dentures if any. The product contains bitrex. Have conscious person drink several glasses of water or milk. Induce vomiting by sticking finger in throat. If vomiting occurs, the head should be kept low so that vomit does not enter the lungs. Never give anything by mouth to an unconscious person. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.

Immediate Medical Attention

Get medical attention following exposure or if feeling unwell. If unconscious, place in recovery position and get medical attention immediately. If necessary, call a poison center or physician.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use dry chemical, CO₂, alcohol-resistant foam or water spray (fog).

Unsuitable media

Do not use water jet.

Specific hazards

In a fire or if heated, a pressure increase will occur and the container may burst.

Instructions

Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training.

Firefighter Protection

Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode. Clothing for fire-fighters (including helmets, protective boots and gloves) conforming to European standard EN 469 will provide a basic level of protection for chemical incidents.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

No action shall be taken involving any personal risk or without suitable training. Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilled material. Avoid breathing vapor or mist.

Small spill

Stop leak if without risk. Move containers from spill area. Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material and place in an appropriate waste disposal container. Dispose of via a licensed waste disposal contractor.

Large spill

Stop leak if without risk. Move containers from spill area. Approach release from upwind. Prevent entry into sewers, water courses, basements or confined areas. Wash spillages into an effluent treatment plant or proceed as follows. Contain and collect spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations. Dispose of via a licensed waste disposal contractor. Contaminated absorbent material may pose the same hazard as the spilled product.

Environmental

Avoid dispersal of spilled material and runoff and contact with soil, waterways, drains and sewers.

Cleanup methods

Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material. Wash spillages into an effluent treatment plant.

Materials: inert dry material, non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Put on appropriate personal protective equipment (see Section 8). Do not breathe vapor or mist. Do not ingest. Avoid contact with eyes, skin and clothing. Keep in the original container or an approved alternative made from a compatible material, kept tightly closed when not in use. Empty containers retain product residue and can be hazardous. Do not reuse container.

Storage

Store in original container protected from direct sunlight in a dry, cool and well-ventilated area, away from incompatible materials (see Section 10) and food and drink. Keep container tightly closed and sealed until ready for use. Containers that have been opened must be carefully resealed and kept upright to prevent leakage. Do not store in unlabeled containers.

Hygiene

Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Remove contaminated clothing and protective equipment before entering eating areas. See also Section 8 for additional information on hygiene measures.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

If user operations generate dust, fumes, gas, vapor or mist, use process enclosures, local exhaust ventilation or other engineering controls to keep worker exposure to airborne contaminants below any recommended or statutory limits.

Hands

Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary. Considering the parameters specified by the glove manufacturer, check during use that the gloves are still retaining their protective properties. It should be noted that the time to breakthrough for any glove material may be different for different glove manufacturers. In the case of mixtures, consisting of several substances, the protection time of the gloves cannot be accurately estimated. Wear suitable gloves tested to EN374. Recommended: < 1 hour (breakthrough time): nitrile rubber 0.17 mm.

Eyes

Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists, gases or dusts. If contact is possible, the following protection should be worn, unless the assessment indicates a higher degree of protection: safety glasses with side-shields.

Respiratory

Based on the hazard and potential for exposure, select a respirator that meets the appropriate standard or certification. Respirators must be used according to a respiratory protection program to ensure proper fitting, training, and other important aspects of use. Recommended: Boiling point > 65 °C: A1; Boiling point < 65 °C: AX1; Hot material: A1P2.

Skin/Body

Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.

Environmental

Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid.
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
Clear.
Colour
Red.
Colour Intensity
Light
Form
---
Odor
Mild.
Odor Threshold
Not available.
Ph
8.6
Melting Point
<-37°C (<-34.6°F)
Boiling Point
>170°C (>338°F)
Flash Point
Closed cup: 122°C (251.6°F) [Pensky-Martens]
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
0.09226 mm Hg (0.012 kPa) (ethanediol)
Vapor Density
2.1 [Air = 1]
Relative Density
---
Bulk Density
---
Density
1.2 g/cm³ [20°C (68°F)]
Flammability
Not applicable.
Upper Explosive Limit
---
Lower Explosive Limit
---
Explosive Limits
---
Auto Ignition Temperature
398°C (748.4°F)
Decomposition Temperature
---
Solubility
---
Partition Coefficient
Not applicable.
Solubility In Water
Easily soluble
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
Not available.
Kinematic Viscosity
Not available.
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is stable.

Reactivity

No specific test data related to reactivity available for this product or its ingredients.

Hazardous reactions

Under normal conditions of storage and use, hazardous reactions will not occur.

Avoid

No specific data.

Incompatible

No specific data.

Decomposition

Under normal conditions of storage and use, hazardous decomposition products should not be produced.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Toxicity

| Product/ingredient name | Result | Species | Exposure | | ethanediol | Acute LC50 6900000 μg/l Fresh water | Crustaceans - Ceriodaphnia dubia - Neonate | 48 hours | | | Acute LC50 41000 mg/l Fresh water | Daphnia - Daphnia magna - Neonate | 48 hours | | | Acute LC50 8050000 μg/l Fresh water | Fish - Pimephales promelas | 96 hours |

12.1 Toxicity

| Product/ingredient name | Result | Species | Exposure | | sodium benzoate | Acute LC50 484000 μg/l Fresh water | Fish - Pimephales promelas | 96 hours |

12.2 Persistence and degradability

Product/ingredient name | Test | Result | Dose | Inoculum | | --- | --- | --- | --- | --- |

12.2 Persistence and degradability

| Product/ingredient name | Test | Result | Dose | Inoculum | | ethanediol | OECD 301A 301A Ready Biodegradability - DOC Die-Away Test | >70 % - 28 days | - | - |

12.2 Persistence and degradability

| Product/ingredient name | Aquatic half-life | Photolysis | Biodegradability | | ethanediol | - | - | Readily |

12.3 Bioaccumulative potential

| Product/ingredient name | LogP_{ow} | BCF | Potential | | ethanediol | -1.36 | - | Low |

12.3 Bioaccumulative potential

| Product/ingredient name | LogP_{ow} | BCF | Potential | | sodium benzoate | -2.27 | - | Low |

12.4 Mobility in soil

Soil/water partition coefficient (Koc) : Not available. Mobility : Not available.

12.5 Results of PBT and vPvB assessment

This mixture does not contain any substances that are assessed to be a PBT or a vPvB.

The mixture does not contain any substances that are assessed to be a PBT or a vPvB.

12.6 Endocrine disrupting properties

Not available.

12.7 Other adverse effects

No known significant effects or critical hazards.

No known significant effects or critical hazards.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

The generation of waste should be avoided or minimized wherever possible. Disposal of this product, solutions and any by-products should at all times comply with the requirements of environmental protection and waste disposal legislation and any regional local authority requirements. Dispose of surplus and non-recyclable products via a licensed waste disposal contractor. Waste should not be disposed of untreated to the sewer unless fully compliant with the requirements of all authorities with jurisdiction.

Disposal

Dispose of surplus and non-recyclable products via a licensed waste disposal contractor.

Waste Codes

16 01 14* antifreeze fluids containing hazardous substances EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

ADR

Transport within user's premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.

IMDG

Transport within user's premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.

IATA

Transport within user's premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

EU Regulation (EC) No. 1907/2006 (REACH)

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Q8 Antifreeze Long Life OAT?

The signal word is warning.

What is the physical form of Q8 Antifreeze Long Life OAT?

Q8 Antifreeze Long Life OAT is a liquid. appearing as clear. with red. color. It has mild. odor.

What is Q8 Antifreeze Long Life OAT used for?

Antifreeze and coolant for engines and industrial equipment

What are the hazard statements for Q8 Antifreeze Long Life OAT?

This substance has 2 hazard statements:

  • H302: Harmful if swallowed.
  • H373: May cause damage to organs through prolonged or repeated exposure.

What is the melting point of Q8 Antifreeze Long Life OAT?

The melting point is <-37°C (<-34.6°F) and the boiling point is >170°C (>338°F).