Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- KPA 2346
Regulatory Identifiers
- CAS Number
- N/A
- UFI Code
- RYMU-34SP-000K-2F5Y
Identified Uses
Additive for Off-Highway.
Uses advised against
None identified.
Manufacturers & Suppliers
LUBRIZOL FRANCE
manufacturer
25 QUAI DE FRANCE CS 61062 76173 ROUEN CEDEX. 76173 FR
(33) 02.35.58.14.00
http://www.mylubrizol.com
Emergency Contacts
Emergency Contact
(+1) 703 527 3887
Osp. Niguarda Ca' Granda
(+39) 02-66101029
24/7
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
GHS09
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Mineral oil | --- | 20 - 50% | Yes |
| zinc bis[O,O-bis(2-ethylhexyl)] bis(dithiophosphate) EC: 224-235-5 | --- | 10 - 25% | Yes |
| 2-tetradecyloxirane, reaction products with boric acid EC: 701-392-2 | --- | 5 - 10% | Yes |
| Triphenyl phosphite EC: 202-908-4 | --- | 1 - 2.5% | Yes |
| O,O,O-triphenyl phosphorothioate EC: 209-909-9 | --- | 0.25 - 1% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove exposed person to fresh air if adverse effects are observed.
Take off contaminated clothing and wash before re-use. Wash skin thoroughly with soap and water. Wash with soap and water. If skin irritation or rash occurs: Get medical attention. If skin irritation occurs, get medical attention. Get medical attention if symptoms occur. Launder contaminated clothing before reuse.
Flush thoroughly with water. If irritation occurs, get medical assistance. Remove contact lenses, if present and easy to do. Continue rinsing.
Rinse mouth. Get medical attention if symptoms occur.
Immediate Medical Attention
No data available.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
CO2, Dry chemical or Foam. Water can be used to cool and protect exposed material.
Not determined.
Elevated temperatures may liberate toxic gases. See section 10 for additional information.
No data available.
Firefighter Protection
Wear full protective firegear including self-containing breathing apparatus operated in the positive pressure mode with full facepiece, coat, pants, gloves and boots.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Ensure adequate ventilation and take proper precautions if decomposition is suspected. Do not touch damaged containers or spilled material unless wearing appropriate protective clothing. Keep unauthorized personnel away. Ventilate area if spilled in confined space or other poorly ventilated areas.
Dike far ahead of larger spill for later recovery and disposal.
Avoid release to the environment. Prevent further leakage or spillage if safe to do so.
Pick up free liquid for recycle and/or disposal. Residual liquid can be absorbed on inert material.
Materials: inert material
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Do not breathe dust/fume/gas/mist/vapors/spray. Avoid contact with eyes, skin, and clothing. Observe good industrial hygiene practices. Provide adequate ventilation. Wear appropriate personal protective equipment. Wash hands thoroughly after handling. Contaminated work clothing should not be allowed out of the workplace. Launder contaminated clothing before reuse. Avoid environmental contamination. Avoid inhalation of vapors upon opening container. Keep container closed when not in use.
Do not reheat or store over maximum handling and storage temperatures.
Wash hands thoroughly after handling. Contaminated work clothing should not be allowed out of the workplace. Launder contaminated clothing before reuse.
Material can accumulate static charges which may cause an electrical spark (ignition source). Use proper bonding and/or grounding procedures.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Ensure proper monitoring, enclosure and ventilation of any bulk container unloading, storage and all storage tank activities, as overheating could lead to hydrogen sulfide (H2S) in headspace. Observe all occupational exposure limits. No special requirements under ordinary conditions of use and with adequate ventilation. Material should be handled in enclosed vessels and equipment, in which case general (mechanical) room ventilation should be sufficient. Local exhaust ventilation should be used at points where dust, mist, vapors or gases can escape into the room air.
Use nitrile or neoprene gloves. Use good industrial hygiene practices. In case of skin contact, wash hands and arms with soap and water. Chemical resistant gloves When material is heated, wear gloves to protect against thermal burns. Gloves should always be inspected before each use and discarded if they show tears, pinholes, or signs of wear. For typical use and handling of chemical substances, gloves should meet the standards set out in EN 374. For applications involving mechanical risks with potential for abrasion or puncture, the standards set out in EN 388 should be considered. For continuous contact, we suggest gloves with a minimum breakthrough time of 240 minutes, or > 480 minutes if suitable gloves can be obtained. For general applications, we recommend gloves with a thickness typically greater than 0.35 mm.
If contact is likely, safety glasses with side shields are recommended. Eye protection should meet the standards set out in EN 166.
A respiratory protection program compliant with all applicable regulations must be followed whenever workplace conditions require the use of a respirator. Under normal use conditions, respirator is not usually required. Use appropriate respiratory protection if exposure to dust particles, mist or vapors is likely. Use self-contained breathing apparatus for entry into confined space, for other poorly ventilated areas and for large spill clean-up sites. Use respirator with an organic vapor cartridge if exposure limit is exceeded. Use disposable dust/mist mask if the recommended exposure limit is exceeded. Respiratory Protective Equipment (RPE) is not normally required where there is adequate natural or local exhaust ventilation to control exposure. In case of insufficient ventilation, wear suitable respiratory equipment.
Thermally protective apron and long sleeves are recommended when volume of hot material is significant. Gloves, coveralls, apron, boots as necessary to minimize contact. Do not wear rings, watches or similar apparel that could entrap the material. Chemical resistant boots.
No data available. See section 6 for details.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Material is stable under normal conditions.
No data available.
Can decompose at elevated temperatures. At elevated temperature may liberate toxic gas.
Keep away from heat, sparks and open flame. Temperatures in excess of max handling and storage temperature guidance provided in "Handling and Storage" section. Steam. If heating is required take care to prevent the presence of localized hotspots which could lead to high skin temperatures and result in decomposition. Do not allow water to enter shipping container or transfer lines. Excessive heat. Do not expose to excessive heat, ignition sources, or oxidizing materials.
oxidizing materials
If heated to decomposition, the following substances may be formed: Hydrogen sulfide Alkyl mercaptans and sulfides may also be released. Thermal decomposition or combustion may generate smoke, carbon monoxide, carbon dioxide, sulfur oxides, mercaptans, sulfides, including hydrogen sulfide and other products of incomplete combustion. Thermal decomposition may generate phosphorus oxides and other phosphorus containing compounds. Thermal decomposition may generate zinc oxides and other zinc containing compounds.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
12.1 Toxicity
12.1 Toxicity
12.1 Toxicity
Aquatic Invertebrates
12.2 Persistence and degradability
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
12.6 Endocrine disrupting properties
12.7 Other adverse effects
12.1 Toxicity
12.2 Persistence and degradability
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
12.6 Endocrine disrupting properties
12.7 Other adverse effects
12.1 Toxicity
12.1 Toxicity
12.1 Toxicity
Toxicity to Aquatic Plants
Toxicity to Aquatic Plants
Toxicity to Aquatic Plants
Toxicity
Toxicity
12.1 Toxicity
Toxicity to microorganisms
12.2 Persistence and Degradability Biodegradation
12.2 Persistence and Degradability Biodegradation
12.2 Persistence and Degradability Biodegradation
12.2 Persistence and Degradability Biodegradation
12.2 Persistence and Degradability Biodegradation
Not readily degradable.
12.3 Bioaccumulative potential Bioconcentration Factor (BCF)
12.3 Bioaccumulative potential
12.3 Bioaccumulative potential
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
The substance/mixture contains no components considered to be either persistent, bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at levels of 0.1% or higher.
12.6 Endocrine disrupting properties:
12.7 Other adverse effects
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Treatment, storage, transportation, and disposal must be in accordance with applicable Federal, State/Provincial, and Local regulations.
Dispose of packaging or containers in accordance with local, regional, national and international regulations.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 3082
- Shipping Name
- ENVIRONMENTALLY HAZARDOUS SUBSTANCE, LIQUID, N.O.S.(Aryl thiophosphate, Zinc alkyldithiophosphate)
- Transport Class
- 9
- Packing Group
- III
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for KPA 2346?
The signal word is warning.
What is the physical form of KPA 2346?
KPA 2346 is a liquid with dark color. It has pungent odor.
What is KPA 2346 used for?
Additive for Off-Highway.
What are the hazard statements for KPA 2346?
This substance has 2 hazard statements:
- H317: May cause an allergic skin reaction.
- H411: Toxic to aquatic life with long lasting effects.