NextSDS Logo
Safety Data Sheet EN

Techniclean AS 105

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Techniclean AS 105
Product Form
Liquid
Product Code
457568-FR01

Regulatory Identifiers

CAS Number
N/A
REACH No.
01-2119453414-43

Identified Uses

Cleaner.

Manufacturers & Suppliers

C

Castrol Industrial - divisie BP Europa SE - BP Belgium

national supplier

Amocolaan 2, 2440 Geel, BELGIUM

+32 (0)800 40752

Emergency Contacts

Carechem

+44 (0) 1235 239 670

24/7

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Asp. Tox. Cat. 1 H304

GHS Pictograms

GHS08 - Serious health hazard

GHS08

Hazard Statements

H304 May be fatal if swallowed and enters airways.

Precautionary Statements

P301 + P310 + P331 IF SWALLOWED: Immediately call a POISON CENTER or physician. Do NOT induce vomiting.
P405 Store locked up.
P501 Dispose of contents and container in accordance with all local, regional, national and international regulations.

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type uvcb
Chemical Name CAS Number Concentration Hazardous
Hydrocarbons, C12-C15, n-alkanes, isoalkanes, cyclics, <2% aromatics --- 100% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

If inhaled, remove to fresh air. Get medical attention if symptoms appear.

Skin contact

Wash skin thoroughly with soap and water or use recognised skin cleanser. Remove contaminated clothing and shoes. Wash clothing before reuse. Clean shoes thoroughly before reuse. Get medical attention if irritation develops.

Eye contact

In case of contact, immediately flush eyes with plenty of water for at least 15 minutes. Eyelids should be held away from the eyeball to ensure thorough rinsing. Check for and remove any contact lenses. Get medical attention.

Ingestion

Do not induce vomiting. Never give anything by mouth to an unconscious person. If unconscious, place in recovery position and get medical attention immediately. Get medical attention immediately.

Symptoms: Aspiration hazard if swallowed. Aspiration hazard Can enter lungs and cause damage.

Immediate Medical Attention

Get medical attention. Get medical attention if irritation develops. Get medical attention if symptoms appear. Get medical attention immediately.

Medical Treatment

Treatment should in general be symptomatic and directed to relieving any effects. Gastric lavage should be undertaken only after endotracheal intubation.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

In case of fire, use foam, dry chemical or carbon dioxide extinguisher or spray.

Unsuitable media

Do not use water jet.

Specific hazards

In a fire or if heated, a pressure increase will occur and the container may burst.

Instructions

Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training.

Firefighter Protection

Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode. Clothing for fire-fighters (including helmets, protective boots and gloves) conforming to European standard EN 469 will provide a basic level of protection for chemical incidents. Fire-fighters' protective clothing will only provide limited protection. Fire fighters should wear positive pressure self-contained breathing apparatus (SCBA) and full turnout gear.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

No action shall be taken involving any personal risk or without suitable training. Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilt material. Floors may be slippery; use care to avoid falling. Avoid breathing vapour or mist. Provide adequate ventilation. Put on appropriate personal protective equipment. Contact emergency personnel.

Small spill

Stop leak if without risk. Move containers from spill area. Absorb with an inert material and place in an appropriate waste disposal container. Dispose of via a licensed waste disposal contractor.

Large spill

Stop leak if without risk. Move containers from spill area. Approach the release from upwind. Prevent entry into sewers, water courses, basements or confined areas. Contain and collect spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations. Contaminated absorbent material may pose the same hazard as the spilt product. Dispose of via a licensed waste disposal contractor.

Environmental

Avoid dispersal of spilt material and runoff and contact with soil, waterways, drains and sewers.

Cleanup methods

Absorb with an inert material and place in an appropriate waste disposal container. Dispose of via a licensed waste disposal contractor.

Materials: inert material, non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Put on appropriate personal protective equipment. Do not swallow. Aspiration hazard if swallowed. Can enter lungs and cause damage. Never siphon by mouth. Avoid contact with eyes, skin and clothing. Avoid breathing vapour or mist. Keep in the original container or an approved alternative made from a compatible material, kept tightly closed when not in use. Do not reuse container. Empty containers retain product residue and can be hazardous. Avoid prolonged or repeated contact with skin. During metal working, solid particles from workpieces or tools will contaminate the fluid and may cause abrasions of the skin. Where such abrasions result in a penetration of the skin, first aid treatment should be applied as soon as reasonably possible. The presence of certain metals in the workpiece or tool, such as chromium, cobalt and nickel, can contaminate the metalworking fluid and as a result may induce allergic skin reactions.

Storage

Store in a dry, cool and well-ventilated area, away from incompatible materials (see Section 10). Store locked up. Keep away from heat and direct sunlight. Keep container tightly closed and sealed until ready for use. Containers that have been opened must be carefully resealed and kept upright to prevent leakage. Store and use only in equipment/ containers designed for use with this product. Do not store in unlabelled containers.

Hygiene

Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Wash thoroughly after handling. Remove contaminated clothing and protective equipment before entering eating areas.

Fire prevention

Keep away from ignition sources such as heat/sparks/open flame. - No smoking.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Provide exhaust ventilation or other engineering controls to keep the relevant airborne concentrations below their respective occupational exposure limits.

Hands

Recommended: Nitrile gloves. Gloves with a minimum breakthrough time of 240 minutes, or >480 minutes if suitable gloves can be obtained. For general applications, we recommend gloves with a thickness typically greater than 0.35 mm. Standards: EN 420, EN 374. Glove selection should be based on consideration of the task requirements and knowledge of breakthrough times; thinner gloves (down to 0.1 mm or less) may be required where a high degree of manual dexterity is needed, while thicker gloves (up to 3 mm or more) may be required where there is a mechanical (as well as a chemical) risk.

Eyes

Safety glasses with side shields. Standards: EN 166.

Respiratory

Use with adequate ventilation. In case of insufficient ventilation, wear suitable respiratory equipment. Recommended: half-face mask - organic vapor filter (Type A). For protection against metal working fluids, respiratory protection that is classified as "resistant to oil" (class R) or oil proof (class P) should be selected where appropriate. Depending on the level of airborne contaminants, an air-purifying, half-mask respirator (with HEPA filter) including disposable (P- or R-series) (for oil mists less than 50mg/m3), or any powered, air-purifying respirator equipped with hood or helmet and HEPA filter (for oil mists less than 125 mg/m3). Where organic vapours are a potential hazard during metalworking operations, a combination particulate and organic vapour filter may be necessary. Standards: EN 529.

Skin/Body

Use of protective clothing is good industrial practice. Wear clothing and footwear that cannot be penetrated by chemicals or oil. Cotton or polyester/cotton overalls will only provide protection against light superficial contamination that will not soak through to the skin. Overalls should be laundered on a regular basis. When the risk of skin exposure is high (e.g. when cleaning up spillages or if there is a risk of splashing) then chemical resistant aprons and/or impervious chemical suits and boots will be required.

Environmental

Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid.
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
Colourless.
Colour Intensity
---
Form
---
Odor
Mild
Odor Threshold
Not available.
Ph
Not available.
Melting Point
Not available.
Boiling Point
Not available.
Flash Point
Closed cup: 102°C (215.6°F) [Pensky-Martens.]
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
<0.01 (1 (Butyl acetate = 1). = 1)
Vapor Pressure
Not available.
Vapor Density
>1 [Air = 1]
Relative Density
---
Bulk Density
---
Density
<1000 kg/m³ (<1 g/cm³) at 15°C
Flammability
---
Upper Explosive Limit
---
Lower Explosive Limit
---
Explosive Limits
---
Auto Ignition Temperature
Not available.
Decomposition Temperature
Not available.
Solubility
insoluble in water.
Partition Coefficient
---
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
Kinematic: <7 mm²/s (<7 cSt) at 40°C Kinematic: 2.2 to 5 mm²/s (2.2 to 5 cSt) at 20°C
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is stable.

Reactivity

No specific test data available for this product. Refer to Conditions to avoid and Incompatible materials for additional information.

Hazardous reactions

Under normal conditions of storage and use, hazardous reactions will not occur. Under normal conditions of storage and use, hazardous polymerisation will not occur.

Avoid

Avoid excessive heat.

Incompatible

Reactive or incompatible with the following materials: oxidising materials.

Decomposition

Under normal conditions of storage and use, hazardous decomposition products should not be produced.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Toxicity

Environmental hazards Not classified as dangerous

12.2 Persistence and degradability

Expected to be biodegradable.

12.3 Bioaccumulative potential

Not available.

12.4 Mobility in soil

Soil/water partition coefficient (Koc) Not available. Mobility Volatile. Liquid. insoluble in water.

The substance is volatile, liquid, and insoluble in water. Soil/water partition coefficient (Koc) is not available.

12.5 Results of PBT and vPvB assessment

PBT No. vPvB No.

The substance is not considered to be PBT or vPvB.

12.6 Other adverse effects

No known significant effects or critical hazards.
13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Dispose of via an authorised person/ licensed waste disposal contractor in accordance with local regulations.

Disposal

Where possible, arrange for product to be recycled. Dispose of via an authorised person/ licensed waste disposal contractor in accordance with local regulations.

Waste Codes

14 06 03* other solvents and solvent mixtures EWC
15 01 10* packaging containing residues of or contaminated by hazardous substances EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The company, as identified in Section 1, sells this product in the EU in compliance with the current requirements of REACH.

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Techniclean AS 105?

The signal word is danger.

What is the physical form of Techniclean AS 105?

Techniclean AS 105 is a liquid. with colourless. color. It has mild odor.

What is the solubility of Techniclean AS 105?

insoluble in water.

What is Techniclean AS 105 used for?

Cleaner.

What are the hazard statements for Techniclean AS 105?

This substance has 1 hazard statement:

  • H304: May be fatal if swallowed and enters airways.

What is the melting point of Techniclean AS 105?

The melting point is Not available. and the boiling point is Not available..