NextSDS Logo
Safety Data Sheet EN

TECHNOMELT PUR CLEANER 2

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
TECHNOMELT PUR CLEANER 2
Product Form
Cleaner
Product Code
238987

Regulatory Identifiers

CAS Number
N/A

Manufacturers & Suppliers

Henkel Corporation logo

Henkel Corporation

manufacturer

One Henkel Way, Rocky Hill, Connecticut 06067

+1 (860) 571-5100

www.henkelna.com

Emergency Contacts

Poison Control Center

1-877-671-4608

Poison Control Center

1-303-592-1711

CHEMTREC

1-800-424-9300

CHEMTREC

1-703-527-3887

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Precautionary Statements

Not prescribed
Not prescribed
Not prescribed
Not prescribed

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Notes

Exact percentages may vary or are trade secret. Concentration range is provided to assist users in providing appropriate protections.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

If not breathing, give artificial respiration. If breathing is difficult, oxygen should be administered by qualified personnel. Move to fresh air. If symptoms persist, seek medical advice.

Symptoms: Asthmatic-type symptoms may develop and may be immediate or delayed up to several hours.

Skin contact

Cool skin rapidly with cold water after contact with molten material. Cover affected areas with clean sheeting or gauze and seek immediate medical attention. No attempt should be made to remove material from skin or to remove contaminated clothing as damaged skin can be easily torn.

Symptoms: Molten adhesive may cause severe burns.

Eye contact

If eye contact occurs with molten material immediately cool with water. Do not remove adhesive. Seek medical attention.

Ingestion

Seek immediate medical attention. Do not induce vomiting. Never give anything by mouth to an unconscious person.

Immediate Medical Attention

Seek immediate medical attention.

Medical Treatment

Persons with asthmatic-type conditions, chronic bronchitis, other chronic respiratory diseases or recurrent skin eczema or sensitization should be excluded from working with isocyanates.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use extinguishing measures appropriate to local circumstances and the surrounding environment. Dry chemical. Carbon dioxide.

Unsuitable media

Not available.

Instructions

Fire fighters should wear positive pressure self-contained breathing apparatus (SCBA). Wear full protective clothing.

Firefighter Protection

Fire fighters should wear positive pressure self-contained breathing apparatus (SCBA). Wear full protective clothing.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Use personal protection recommended in Section 8, isolate the hazard area and deny entry to unnecessary and unprotected personnel.

Environmental

No special environmental precautions required. Do not allow material to contaminate ground water system.

Cleanup methods

Spilled material will solidify. Scrape up spilled material and place in a closed container for disposal.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Always be careful around molten material. Avoid skin contact with molten resins. Follow suggested application temperature. Do not wear contact lenses. At elevated temperatures, irritating fumes may be emitted. Wash hands before breaks and immediately after handling the product.

Storage

Store in a cool, dry, well-ventilated area.

Hygiene

Wash hands before breaks and immediately after handling the product.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Work should be done in an adequately ventilated area (i.e., ventilation sufficient to maintain concentrations below one half of the PEL and other relevant standards). Local exhaust ventilation is recommended when general ventilation is not sufficient to control airborne contamination.

Hands

Insulated gloves are strongly recommended when working with molten adhesive.

Eyes

Safety goggles or safety glasses with side shields. Full face protection should be used if the potential for splashing or spraying of product exists. Do not wear contact lenses.

Respiratory

No personal respiratory protective equipment normally required. Where the potential exists for exposure to decomposition products due to heating or elevated temperatures, wear NIOSH approved respiratory protection as appropriate. Observe OSHA regulations for respirator use (29 CFR 1910.134).

Skin/Body

Long sleeved clothing are strongly recommended when working with molten adhesive.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Colour
Light blue
Relative Density
---
Metal Corrosion
---
Upper Explosive Limit
Not available.
Form
---
Cloud Point
---
Odor
Neutral
Physical State Data
solid
Ph
Product is non-soluble (in water),, Not applicable
Solubility In Water
---
Explosive Limits
---
Voc Content
Negligible
Molecular Weight
---
Appearance
---
Melting Point
70 °C (158°F)
Bulk Density
---
Relative Evaporation Rate
---
Colour Intensity
---
Dynamic Viscosity
5,500 - 7,500 mPa.s
State Under Standard Conditions
---
Odor Threshold
Not available.
Vapor Pressure
< 0.001 hPa (38 °C (100.4 °F)) < 0.001 hPa (20 °C (68°F))
Auto Ignition Temperature
Not applicable
Kinematic Viscosity
Not available.
Solidification Point
---
Evaporation Rate
Not applicable
Flammability
The product is not flammable.
Lower Explosive Limit
Not available.
Freezing Point
---
Crystallisation Point
---
Solubility
Insoluble Water
Softening Point
---
Flash Point
Not applicable
Properties Status
---
Solubility In Fat
---
Partition Coefficient
Not available.
Density
---
Boiling Point
340 - 390 °C (644°F - 734°F)
Physical State
Solid
Vapor Density
---
Decomposition Temperature
Not available.
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under recommended storage conditions.

Reactivity

Not available.

Hazardous reactions

Will not occur.

Avoid

To avoid thermal decomposition, do not overheat. Avoid temperatures above 200°C (392°F).

Incompatible

Oxidizing agents.

Decomposition

Thermal decomposition can lead to release of irritating gases and vapors. Carbon monoxide. Carbon dioxide.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for TECHNOMELT PUR CLEANER 2?

The signal word is no signal word.

What is the physical form of TECHNOMELT PUR CLEANER 2?

TECHNOMELT PUR CLEANER 2 is a solid with light blue color. It has neutral odor.

What is the solubility of TECHNOMELT PUR CLEANER 2?

Insoluble Water

What is the melting point of TECHNOMELT PUR CLEANER 2?

The melting point is 70 °C (158°F) and the boiling point is 340 - 390 °C (644°F - 734°F).