Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Infineum R511
- Product Code
- 81450
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Additive for petroleum fuels
Uses advised against
This material should not be used for any other purpose than that recommended without expert advice.
Manufacturers & Suppliers
INFINEUM UK LIMITED
manufacturer
P. O. Box 1 Milton Hill Abingdon Oxfordshire OX13 6BB United Kingdom
http://www.infineum.com
Emergency Contacts
Emergency Contact
04-4274.4690
Emergency Contact
+33-4.4274.4690
Emergency Contact
0221-7499 3355
Emergency Contact
+49-221-7499 3355
Emergency Contact
019-2150 221
Emergency Contact
+39 019-2150 221
Emergency Contact
01235 549777
Emergency Contact
+44 1235 549777
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| solvent naphtha (petroleum), heavy arom. EC: 265-198-5 | --- | 30 - 50% | Yes |
| naphthalene EC: 202-049-5 | --- | 2.5 - 5% | Yes |
| kerosine (petroleum), hydrodesulfurized EC: 265-184-9 | --- | 1 - 5% | Yes |
| 1,2,4-trimethylbenzene EC: 202-436-9 | --- | 1 - 2.5% | Yes |
| 1,3,5-trimethylbenzene EC: 203-604-4 | --- | 0.25% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to fresh air. Consult a physician after significant exposure.
Take off contaminated clothing and shoes immediately. Wash off with soap and plenty of water. If symptoms persist, call a physician. In case of burns apply cold water until pain subsides then seek medical advice.
Flush eyes with water as a precaution. Remove contact lenses. Protect unharmed eye. Keep eye wide open while rinsing. If eye irritation persists, consult a specialist.
Clean mouth with water and drink afterwards plenty of water. Never give anything by mouth to an unconscious person. Obtain medical attention.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use water fog, foam, dry chemical or carbon dioxide (CO2) to extinguish flames
Combustible.
Collect contaminated fire extinguishing water separately. This must not be discharged into drains. Fire residues and contaminated fire extinguishing water must be disposed of in accordance with local regulations.
Firefighter Protection
In the event of fire, wear self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Avoid contact with spilled material. Do not touch or walk through spilled material.
Dyke far ahead of liquid spill for later recovery and disposal.
Prevent entry into waterways, sewers, basements or confined areas. Do not flush into surface water or sanitary sewer system. Prevent further leakage or spillage if safe to do so.
Recover by pumping or with suitable absorbent. Seek the advice of a specialist before using dispersants.
Materials: inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust)
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Smoking, eating and drinking should be prohibited in the application area. Dispose of rinse water in accordance with local and national regulations. Take precautionary measures against static discharges. Ensure all equipment is electrically grounded before beginning transfer operations. Normal measures for preventive fire protection.
Keep container tightly closed in a dry and well-ventilated place. Containers which are opened must be carefully resealed and kept upright to prevent leakage. No decomposition if stored and applied as directed.
Smoking, eating and drinking should be prohibited in the application area.
Normal measures for preventive fire protection.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
No special requirements under ordinary conditions of use and with adequate ventilation.
Solvent-resistant gloves. Before removing gloves clean them with soap and water. Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. Also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion, and the contact time. When handling hot material, use heat resistant gloves. The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it.
Eye wash bottle with pure water. Tightly fitting safety goggles.
In the case of vapour formation use a respirator with an approved filter.
impervious clothing. Choose body protection according to the amount and concentration of the dangerous substance at the work place. Long sleeved clothing.
Prevent entry into waterways, sewers, basements or confined areas. Do not flush into surface water or sanitary sewer system. Prevent further leakage or spillage if safe to do so. If the product contaminates rivers and lakes or drains inform respective authorities.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
Elevated temperatures. Open flames and high energy ignition sources.
Strong oxidizing agents
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
12.1 Toxicity
Bioaccumulative potential
The bioaccumulative potential is referred to Section 9.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The product should not be allowed to enter drains, water courses or the soil.
Offer surplus and non-recyclable solutions to a licensed disposal company.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN3082
- Shipping Name
- ENVIRONMENTALLY HAZARDOUS SUBSTANCE, LIQUID, N.O.S. (Alkyl (C3-C5) benzenes)
- Transport Class
- 9
- Packing Group
- III
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Risk classification according to VbF: Flash Point > 55 °C up to 100 °C, at 15 °C not miscible with water.
Take note of Dir 92/85/EEC on the safety and health at work of pregnant workers. Take note of Dir 94/33/EC on the protection of young people at work.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Infineum R511?
The signal word is na: r-phrases.
What is the physical form of Infineum R511?
Infineum R511 is a liquid appearing as light yellow with light yellow color. It has hydrocarbon-like odor.
What is Infineum R511 used for?
Additive for petroleum fuels
What is the melting point of Infineum R511?
The melting point is not determined and the boiling point is not determined.