NextSDS Logo
Safety Data Sheet EN

Infineum V387

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Infineum V387
Product Code
80130

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Flow-improver and pour point depressant

Uses advised against

This material should not be used for any other purpose than that recommended without expert advice.

Manufacturers & Suppliers

M

Multisol Europe Limited

national supplier

5100 Daresbury Park, Daresbury, Warrington, WA4 4GE, United Kingdom

+44 (0) 01928 717071

Emergency Contacts

Emergency Contact

+44 (0) 1270 502894

24 hour

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Distillates (petroleum), solvent-dewaxed light paraffinic EC: 265-159-2 --- 1 - 10% Yes

Other ingredients are either not hazardous or are below the regulatory disclosure limit..

Notes

All concentrations are weight percent units for liquids or volume percent units for gaseous products.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

If unconscious, place in recovery position and seek medical advice. If symptoms persist, call a physician.

Skin contact

Take off contaminated clothing and shoes immediately. Wash off with soap and plenty of water. If symptoms persist, call a physician. In case of burns apply cold water until pain subsides then seek medical advice.

Eye contact

Flush eyes with water as a precaution. Remove contact lenses. Protect unharmed eye. Keep eye wide open while rinsing. If eye irritation persists: Get medical advice/ attention.

Ingestion

Clean mouth with water and drink afterwards plenty of water. Do not give milk or alcoholic beverages. Never give anything by mouth to an unconscious person. If symptoms persist, call a physician.

Medical Treatment

If a person vomits when lying on his back, place him in the recovery position. Keep patient warm and at rest.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use water fog, foam, dry chemical or carbon dioxide (CO2) to extinguish flames

Unsuitable media

Do NOT use water jet.

Specific hazards

Not classified as flammable or combustible, but will combust if ignited. Carbon monoxide, carbon dioxide and unburned hydrocarbons (smoke).

Instructions

Standard procedure for chemical fires. Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.

Firefighter Protection

Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Avoid contact with spilled material. Do not touch or walk through spilled material.

Small spill

Wipe up with absorbent material (e.g. cloth, fleece).

Large spill

Dyke far ahead of liquid spill for later recovery and disposal. Recover by pumping or with suitable absorbent

Environmental

No Exposure Scenario annex is attached to this safety data sheet as it is a non-classified mixture containing no hazardous substances.

Cleanup methods

Recover by pumping or with suitable absorbent. Wipe up with absorbent material (e.g. cloth, fleece).

Materials: absorbent material (e.g. cloth, fleece)

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

For personal protection see section 8.

Storage

Keep container tightly closed in a dry and well-ventilated place.

Hygiene

Smoking, eating and drinking should be prohibited in the application area.

Fire prevention

Normal measures for preventive fire protection.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No Exposure Scenario annex is attached to this safety data sheet as it is a non-classified mixture containing no hazardous substances. No special requirements under ordinary conditions of use and with adequate ventilation.

Hands

Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. Also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion, and the contact time. When handling hot material, use heat resistant gloves. For prolonged or repeated contact use protective gloves. The selected protective gloves have to satisfy the specifications of Regulation (EU) 2016/425 and the standard EN 374 derived from it.

Eyes

Safety glasses. The applicable European standard can be found in EN 166.

Respiratory

No personal respiratory protective equipment normally required. The applicable European standard can be found in EN 140, EN 137, EN 143, EN 14387.

Skin/Body

Long sleeved clothing. The applicable European standard can be found in EN 14605.

Environmental

No Exposure Scenario annex is attached to this safety data sheet as it is a non-classified mixture containing no hazardous substances. Prevent entry into waterways, sewers, basements or confined areas. Do not flush into surface water or sanitary sewer system. Prevent further leakage or spillage if safe to do so. Try to prevent the material from entering drains or water courses. If the product contaminates rivers and lakes or drains inform respective authorities.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
clear
Colour Intensity
---
Form
viscous
Odor
hydrocarbon-like
Odor Threshold
not determined
Ph
Not applicable
Melting Point
not determined
Boiling Point
not determined
Flash Point
Pensky-Martens Closed Cup (ASTM D93) 155 °C (311 ° F)
Freezing Point
not determined
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
negligible
Vapor Pressure
0.9 hPa (0.7 mmHg) at 20 °C (68 ° F)
Vapor Density
not determined
Relative Density
0.919 at 15.6 °C (60.1 ° F)
Bulk Density
Not applicable
Density
0.917 g/cm3 at 15 °C (59 ° F)
Flammability
not determined
Upper Explosive Limit
not determined
Lower Explosive Limit
not determined
Explosive Limits
---
Auto Ignition Temperature
Not applicable
Decomposition Temperature
not determined
Solubility
---
Partition Coefficient
not determined
Solubility In Water
< 0.0001 g/l estimated
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
93 mm2/s at 100 °C (212 ° F); 740 mm2/s at 40 °C (104 ° F)
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under recommended storage conditions.

Reactivity

No dangerous reaction known under conditions of normal use.

Hazardous reactions

No hazards to be specially mentioned.

Avoid

Excessive heat.

Incompatible

Strong oxidizing agents

Decomposition

No decomposition if used as directed.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Toxicity

Product: Toxicity to fish | : | No data is available on the product itself. Toxicity to daphnia and other : No data is available on the product itself. aquatic invertebrates Toxicity to algae | : | No data is available on the product itself.

12.2 Persistence and degradability

Product: Biodegradability | : | No data is available on the product itself.

12.3 Bioaccumulative potential

Product: Bioaccumulation | : | No data is available on the product itself. Partition coefficient: n- | : | not determined octanol/water

12.4 Mobility in soil

Product: Mobility | : | No data is available on the product itself. Components:

12.4 Mobility in soil

Distillates (petroleum), solvent-dewaxed light paraffinic : Mobility | : | After release, adsorbs onto soil.

12.5 Results of PBT and vPvB assessment

Assessment | : | No data is available on the product itself. This substance/mixture contains no components considered to be either persistent, bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at levels of 0.1% or higher.

The substance/mixture contains no components considered to be either persistent, bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at levels of 0.1% or higher.

12.5 Results of PBT and vPvB assessment

Distillates (petroleum), solvent-dewaxed light paraffinic : Assessment | : | This substance is not considered to be persistent, bioaccumulating and toxic (PBT)., This substance is not considered to be very persistent and very bioaccumulating (vPvB).

The substance is not considered to be persistent, bioaccumulating and toxic (PBT) or very persistent and very bioaccumulating (vPvB).

12.6 Endocrine Disrupting Properties

Product: Assessment | : | No data is available on the product itself.

No data is available on the product itself.

12.7 Other adverse effects

Additional ecological information: None known.

None known.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Dispose of contents/ container to an approved waste disposal plant.

Disposal

Disposal recommendations based on material as supplied, Disposal must be in accordance with applicable laws and regulations, and material characteristics at time of disposal

Waste Codes

13 02 XX waste engine, gear and lubricating oils EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

To import this product into the EU your company requires registrations for all constituent substances that are subject to REACH registration.

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Infineum V387?

The signal word is no signal word.

What is the physical form of Infineum V387?

Infineum V387 is a liquid with clear color. It has hydrocarbon-like odor.

What is Infineum V387 used for?

Flow-improver and pour point depressant

What is the melting point of Infineum V387?

The melting point is not determined and the boiling point is not determined.