Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
MONO ETHYLENE GLYCOL
Product Form
Substance
Chemical Name
ethane-1,2-diol

Regulatory Identifiers

CAS Number
107-21-1 Check regulations →
EC Number
203-473-3 Check regulations →
REACH No.
01-2119456816-28-XXXX

Identified Uses

Solvent

Uses advised against

No additional information available

Manufacturers & Suppliers

S

SOLVENTIS EUROPE NV

Sint Maartenstraat 1 2000 Antwerpen - BELGIUM

+32 3 205 16 66

S

Solventis Ltd

Compton House, The Guildway, Old Portsmouth Road, Guildford GU3 1LR Surrey - UK

+44 1483 203224

Emergency Contacts

Emergency Contact

+32 (0)3 575 55 55

24 hours per day, 7 days per week

National Poisons Information Centre Beaumont Hospital

+353 1 809 2566

National Poisons Information Centre Beaumont Hospital

+353 1 809 2166

8am - 10pm,7/7

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Acute Tox. Cat. 4 H302
STOT RE Cat. 2 H373

GHS Pictograms

GHS07 - Health hazard

GHS07

GHS08 - Serious health hazard

GHS08

Hazard Statements

H302 Harmful if swallowed.
H373 May cause damage to organs through prolonged or repeated exposure.

Precautionary Statements

P260 Do not breathe vapours.
P264 Wash Skin thoroughly after handling.
P270 Do not eat, drink or smoke when using this product.
P301 + P312 IF SWALLOWED: Call a POISON CENTER, a doctor if you feel unwell.
P330 Rinse mouth.
P501 Dispose of contents and container to an approved waste disposal plant.

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
ethanediol; ethylene glycol EC: 203-473-3 107-21-1 100% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove casualty to fresh air and keep warm and at rest. Give oxygen or artificial respiration if necessary. In case of doubt or persistent symptoms, consult always a physician. If unconscious place in recovery position and seek medical advice.

Symptoms: Cough, Dizziness, Headache.

Skin contact

Remove contaminated clothing and shoes. Gently wash with plenty of soap and water. Wash contaminated clothing before reuse. In case of doubt or persistent symptoms, consult always a physician.

Symptoms: Dry skin.

Eye contact

Rinse immediately carefully and thoroughly with eye-bath or water. Remove contact lenses, if present and easy to do. Continue rinsing. In case of doubt or persistent symptoms, consult always a physician.

Symptoms: erythema (redness), Pain.

Ingestion

Get immediate medical advice/attention. Rinse mouth thoroughly with water. Rinse mouth immediately and drink plenty of water. If swallowed, do not induce vomiting: seek medical advice immediately and show this container or label. If a person vomits when lying on his back, place him in the recovery position. Never give anything by mouth to an unconscious person.

Symptoms: Abdominal pain, Drowsiness, Dizziness, Nausea, Headache, Vomiting, Unconsciousness, Impairment of the nervous system, Liver and kidney injuries may occur.

Immediate Medical Attention

Get immediate medical advice/attention. In case of doubt or persistent symptoms, consult always a physician.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

carbon dioxide (CO2), powder, alcohol-resistant foam, water spray.

Unsuitable media

Strong water jet.

Specific hazards

Not flammable. Heating will cause a rise in pressure with a risk of bursting.

Instructions

Evacuate area. Use water spray or fog for cooling exposed containers. Contain the extinguishing fluids by bunding. Prevent fire fighting water from entering the environment.

Firefighter Protection

Do not attempt to take action without suitable protective equipment. Self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Evacuate unnecessary personnel. Keep upwind. Provide adequate ventilation. Do not breathe vapours. Avoid contact with skin, eyes and clothing. Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.

Small spill

Small quantities of liquid spill: take up in non-combustible absorbent material and shovel into container for disposal.

Large spill

Recover large spills by pumping (use an explosion proof or hand pump).

Environmental

Do not allow to enter into surface water or drains.

Cleanup methods

Stop leak if safe to do so. Dam up the liquid spill. Small quantities of liquid spill: take up in non-combustible absorbent material and shovel into container for disposal. Recover large spills by pumping (use an explosion proof or hand pump). Place in a suitable container for disposal in accordance with the waste regulations (see Section 13).

Materials: non-combustible absorbent material

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Provide adequate ventilation. Do not breathe vapours. Avoid contact with skin, eyes and clothing. Use personal protective equipment as required. Concerning personal protective equipment to use, see section 8. Take any precaution to avoid mixing with Incompatible materials, Refer to Section 10 on Incompatible Materials. Ensure proper process control to avoid excess waste discharge (temperature, concentration, pH, time). Avoid release to the environment. Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.

Storage

Store in a dry, cool and well-ventilated place. Do not store near or with any of the incompatible materials listed in section 10. Bund storage facilities to prevent soil and water pollution in the event of spillage. Take precautionary measures against static discharge. Hydroscopic.

Hygiene

Keep good industrial hygiene. Wash hands and other exposed areas with mild soap and water before eating, drinking or smoking and when leaving work. Do not eat, drink or smoke when using this product. Keep away from food, drink and animal feedingstuffs. Remove contaminated clothes. Separate working clothes from town clothes. Launder separately. Wash contaminated clothing before reuse.

Fire prevention

Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Provide adequate ventilation. Use only in area provided with appropriate exhaust ventilation. Emergency eye wash fountains and safety showers should be available in the immediate vicinity of any potential exposure. Provide adequate precautions, such as electrical grounding and bonding, or inert atmospheres. Take precautionary measures against static discharges. Organisational measures to prevent /limit releases, dispersion and exposure. See Section 7 for information on safe handling.

Hands

Wear chemically resistant gloves (tested to EN374) . Suitable material: Polyvinyl alcohol. neoprene gloves. NBR (Nitrile rubber). Breakthrough time : : > 480 m. Thickness of the glove material: : 0,11 mm. The quality of the protective gloves resistant to chemicals must be chosen as a function of the specific working place concentration and quantity of hazardous substances.

Eyes

Use suitable eye protection (EN166): Safety glasses. During splash contact: face shield

Respiratory

Not required for normal conditions of use. In case of insufficient ventilation, wear suitable respiratory equipment. full face mask (DIN EN 136). Half-face mask (DIN EN 140). Filter type: A/P (EN 14387). The filter class must be suitable for the maximum contaminant concentration (gas/vapour/aerosol/particulates) that may arise when handling the product. If the concentration is exceeded, self-contained breathing apparatus must be used. (EN 137)

Skin/Body

Wear suitable protective clothing. Wear suitable coveralls to prevent exposure to the skin

Environmental

Avoid release to the environment. Comply with applicable Community environmental protection legislation.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
viscous liquid.
Colour
Colourless.
Colour Intensity
---
Form
---
Odor
odourless.
Odor Threshold
No data available
Ph
No data available
Melting Point
-13 °C
Boiling Point
197,4 °C
Flash Point
111 °C
Freezing Point
No data available
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
0,123 hPa (25 °C)
Vapor Density
No data available
Relative Density
1,11 (20 °C)
Bulk Density
---
Density
1110 kg/m³
Flammability
Not applicable,liquid,Not applicable,liquid
Upper Explosive Limit
43 vol %
Lower Explosive Limit
3,2 vol %
Explosive Limits
---
Auto Ignition Temperature
398 °C
Decomposition Temperature
No data available
Solubility
Water: No data available
Partition Coefficient
-1,36
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
16,1 mPa.s (25 °C)
Kinematic Viscosity
24,8 mm²/s (20 °C)
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Hygroscopic.

Reactivity

None under normal conditions. Reference to other sections: 10.4 & 10.5.

Hazardous reactions

Risk of explosion. : Perchloric acid. Incompatible materials. Reference to other sections 10.5. Vapours may form explosive mixture with air. Reference to other sections 10.4.

Avoid

Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. Protect from sunlight. See Section 7 for information on safe handling.

Incompatible

Perchloric acid

Decomposition

Reference to other sections 5.2.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1. Toxicity

Environmental properties : According to the criteria of the European classification and labelling system, the substance/the product has not to be labelled as "dangerous for the environment". Hazardous to the aquatic environment, short– term (acute) : Not classified Hazardous to the aquatic environment, long– term (chronic) : Not classified

The substance is not classified as dangerous for the environment according to European criteria.

12.1. Toxicity

Environmental properties : According to the criteria of the European classification and labelling system, the substance/the product has not to be labelled as "dangerous for the environment". |ethanediol; ethyleneglycol(107-21-1)|| |---|---| |LC50 - Fish [1]|41000 mg/l (Exposure time: 96 h - Species: Oncorhynchus mykiss)| |LC50 - Fish [2]|14 – 18 ml/l (Exposure time: 96 h - Species: Oncorhynchus mykiss [static])| |EC50 - Crustacea [1]|46300 mg/l (Exposure time: 48 h - Species: Daphnia magna)| |EC50 96h - Algae [1]|6500 – 13000 mg/l (Species: Pseudokirchneriella subcapitata)| |NOEC (chronic)|15380 mg/l (7d, Pimephales promelas)|

12.2. Persistence and degradability

12.2. Persistence and degradability

MONO ETHYLENE GLYCOL(107-21-1) | Persistence and degradability | Readily biodegradable.

Readily biodegradable.

12.2. Persistence and degradability

Persistence and degradability: Readily biodegradable. Biodegradation: 90-100 Experimental data

12.3. Bioaccumulative potential

|**MONO ETHYLENE GLYCOL(107-21-1)**|| |---|---| |Partition coefficient n-octanol/water|-1,36| |Bioaccumulative potential|No additional information available.|

12.3. Bioaccumulative potential

|**ethanediol; ethyleneglycol(107-21-1)**|| |---|---| |Partition coefficient n-octanol/water|-1,36| |Bioaccumulative potential|Does not bioaccumulate.|

Does not bioaccumulate.

12.4. Mobility in soil

MONO ETHYLENE GLYCOL(107-21-1) Mobility in soil: No data available Ecology - soil: Expected to be highly mobile in soil. ethanediol; ethyleneglycol(107-21-1) Mobility in soil: Not expected to adsorb on soil.

12.5. Results of PBT and vPvB assessment

This substance/mixture does not meet the PBT criteria of REACH regulation, annex XIII This substance/mixture does not meet the vPvB criteria of REACH regulation, annex XIII

The substance does not meet the PBT or vPvB criteria of REACH regulation, annex XIII.

12.6. Endocrine disrupting properties

Adverse effects on the environment caused by endocrine disrupting properties - : The substance is not included in the list established in accordance with Article 59(1) of REACH for having endocrine disrupting properties, or is not identified as having endocrine disrupting properties in accordance with the criteria set out in Commission Delegated Regulation (EU) 2017/2100 or Commission Regulation (EU) 2018/605

12.7. Other adverse effects

Other adverse effects - : No data available
13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Avoid release to the environment. Dispose of empty containers and wastes safely. See Section 7 for information on safe handling. Refer to manufacturer/supplier for information on recovery/recycling. Recycling is preferred to disposal or incineration. If recycling is not possible, eliminate in accordance with local valid waste disposal regulations.

Disposal

Dispose of contaminated materials in accordance with current regulations.

Waste Codes

070104* The following Waste Codes are only suggestions EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

This safety datasheet has been prepared according to Polish legislation.

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for MONO ETHYLENE GLYCOL?

The signal word is warning.

What is the physical form of MONO ETHYLENE GLYCOL?

MONO ETHYLENE GLYCOL is a liquid appearing as viscous liquid. with colourless. color. It has odourless. odor.

What is the solubility of MONO ETHYLENE GLYCOL?

Water: No data available

What is MONO ETHYLENE GLYCOL used for?

Solvent

What are the hazard statements for MONO ETHYLENE GLYCOL?

This substance has 2 hazard statements:

  • H302: Harmful if swallowed.
  • H373: May cause damage to organs through prolonged or repeated exposure.

What is the melting point of MONO ETHYLENE GLYCOL?

The melting point is -13 °C and the boiling point is 197,4 °C.