Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Rando HD LVZ 68
- Product Code
- 801354
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Hydraulic Oil
Uses advised against
Consult supplier when used other than those specified.
Manufacturers & Suppliers
Chevron Belgium BV
manufacturer
Zuiderpoort Office Park, Gaston Crommenlaan 4, 9050 Gent, Belgium
0032/(0)9 293 71 11
Emergency Contacts
CHEMTREC
+1 703 527 3887
Centre Antipoisons
+32022649636
Chevron Emergency Information Center
+1 510 231 0623
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Lubricating oils, petroleum, C20-50, hydrotreated neutral oil-based EC: 276-738-4 | 72623-87-1 | 70 - 99% | No |
| 2,6-di-tert-butylphenol EC: 204-884-0 | 128-39-2 | 0.1 - 1% | Yes |
| Benzenamine, N-phenyl-, reaction products with 2,4,4-trimethylpentene EC: 270-128-1 | 68411-46-1 | 0.1 - 1% | Yes |
In accordance with the Regulation (EC)No 1272/2008, Nota L, reference IP 346/92: "DMSO Extraction Method", we have determined that the base oils used in this preparation are not carcinogenic.
First Aid Measures
Emergency procedures for chemical exposure incidents
If exposed to excessive levels of material in the air, move the exposed person to fresh air.
Symptoms: Not expected to be harmful if inhaled. Contains a petroleum-based mineral oil. May cause respiratory irritation or other pulmonary effects following prolonged or repeated inhalation of oil mist at airborne levels above the recommended mineral oil mist exposure limit. Symptoms of respiratory irritation may include coughing and difficulty breathing.
As a precaution, remove clothing and shoes if contaminated. To remove the material from skin, use soap and water. Discard contaminated clothing and shoes or thoroughly clean before reuse.
Symptoms: High-Pressure Equipment Information: Accidental high-velocity injection under the skin of materials of this type may result in serious injury. The initial wound at the injection site may not appear to be serious at first; but, if left untreated, could result in disfigurement or amputation of the affected part. Contact with the skin is not expected to be harmful.
As a precaution, remove contact lenses, if worn, and flush eyes with water.
Symptoms: Not expected to cause prolonged or significant eye irritation.
Do not induce vomiting.
Symptoms: Not expected to be harmful if swallowed.
Immediate Medical Attention
Get medical attention if coughing or respiratory discomfort occurs. As a precaution, get medical advice if ingested.
Medical Treatment
Not applicable.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use water fog, foam, dry chemical or carbon dioxide (CO2) to extinguish flames.
A complex mixture of airborne solids, liquids, and gases including carbon monoxide, carbon dioxide, and unidentified organic compounds will be evolved when this material undergoes combustion.
For fires involving this material, do not enter any enclosed or confined fire space without proper protective equipment, including self-contained breathing apparatus.
Firefighter Protection
Do not enter any enclosed or confined fire space without proper protective equipment, including self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Observe all relevant local and international regulations. Keep out unnecessary and unprotected personnel. Persons entering the contaminated area to correct the problem or to determine whether it is safe to resume normal activities must comply with all instructions in the Exposure Controls/PersonalProtection section.
Stop the source of the release if you can do it without risk. Contain release to prevent further contamination of soil, surface water or groundwater.
Clean up spill as soon as possible, observing precautions in Exposure Controls/Personal Protection.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Do not get in eyes, on skin, or on clothing. Do not taste or swallow. Wash thoroughly after handling.
Not Applicable
Wash thoroughly after handling.
Review all operations which have the potential of generating and accumulating an electrostatic charge and/or a flammable atmosphere (including tank and container filling, splash filling, tank cleaning, sampling, gauging, switch loading, filtering, mixing, agitation, and vacuum truck operations) and use appropriate mitigating procedures.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Use in a well-ventilated area.
Selection of chemical protective clothing should be performed by an Occupational Hygienist or Safety Professional and be based upon applicable standards (ASTM F739 or EN 374). Using chemical PPE depends upon operations conducted and may include chemical gloves. Refer to PPE manufacturers to obtain breakthrough time information. Chemical Glove Material: Butyl (0.7 mm, 120 minutes), Neoprene (0.61 mm, 120 minutes), Nitrile (0.8 mm, 120 minutes), Polyvinyl Chloride (PVC) (1.1 mm, 120 minutes), Viton Butyl (0.3 mm, 120 minutes).
Wear protective equipment to prevent eye contact. Selection of protective equipment may include safety glasses, chemical goggles, face shields, or a combination depending on the work operations conducted.
No respiratory protection is normally required. If user operations generate an oil mist, determine if airborne concentrations are below the occupational exposure limit for mineral oil mist. If not, wear an approved respirator that provides adequate protection from the measured concentrations of this material. For air-purifying respirators use a particulate cartridge.
Wear chemical personal protective equipment (PPE) to prevent skin contact. Selection of chemical protective clothing should be performed by an Occupational Hygienist or Safety Professional and be based upon applicable standards (ASTM F739 or EN 374). Using chemical PPE depends upon operations conducted and may include chemical gloves, boots, chemical apron, chemical suit, and complete facial protection.
See relevant Community environmental protection legislation or the Annex, as applicable.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
This material is considered stable under normal ambient and anticipated storage and handling conditions of temperature and pressure.
May react with strong acids or strong oxidizing agents, such as chlorates, nitrates, peroxides, etc.
Hazardous polymerization will not occur.
Not applicable
Not applicable
None known (None expected)
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
12.1 Toxicity
12.2 Persistence and degradability
12.2 Persistence and degradability
12.2 Persistence and degradability
12.1 Toxicity
12.2 Persistence and degradability
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
The product is not, or does not contain, a substance that is a potential PBT or a vPvB.
12.6 Endocrine Disrupting Properties
The mixture does not contain any substances that are assessed as having endocrine disrupting properties.
12.1 Toxicity
12.7 Other adverse effects
12.1 Toxicity
12.1 Toxicity
Based on available data, the classification criteria are not met
12.1 Toxicity
No test data available for long-term toxicity.
Bioaccumulative Potential
Based on available data, the classification criteria are not met
Bioaccumulative Potential
Bioaccumulative Potential
No test data available for bioaccumulative potential.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Use material for its intended purpose or recycle if possible. Oil collection services are available for used oil recycling or disposal.
Contact your sales representative or local environmental or health authorities for approved disposal or recycling methods.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
No components of this material were found on the regulatory lists above.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Rando HD LVZ 68?
The signal word is no signal word.
What is the physical form of Rando HD LVZ 68?
Rando HD LVZ 68 is a liquid appearing as colorless to yellow with colorless to yellow color. It has petroleum odor odor.
What is the solubility of Rando HD LVZ 68?
Soluble in hydrocarbons; insoluble in water
What is Rando HD LVZ 68 used for?
Hydraulic Oil
What are the hazard statements for Rando HD LVZ 68?
This substance has 1 hazard statement:
- H412: Harmful to aquatic life with long lasting effects
What is the melting point of Rando HD LVZ 68?