Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Rando HD 10
- Product Code
- 831448
Regulatory Identifiers
- CAS Number
- N/A
- UFI Code
- PF87-802E-900K-W8GW
Identified Uses
Hydraulic Oil
Manufacturers & Suppliers
Uno-X Smøreolje AS
national supplier
Gladengveien 2, NO-0661 Oslo, Norway
http://www.olje.unox.no
Emergency Contacts
CHEMTREC
+1 703 527 3887
Chevron Emergency Information Center
+1 510 231 0623
International calls accepted 24 hours
Poison Control Centre Norway
0047/22591300
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS08
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
This material is a mixture.
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Distillates (petroleum), hydrotreated middle EC: 265-148-2 | 64742-46-7 | 70 - 99% | Yes |
| 2,6-di-tert-butylphenol EC: 204-884-0 | 128-39-2 | 0.25% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
No specific first aid measures are required. If exposed to excessive levels of material in the air, move the exposed person to fresh air. Get medical attention if coughing or respiratory discomfort occurs.
Symptoms: Not expected to be harmful if inhaled. Contains a petroleum-based mineral oil. May cause respiratory irritation or other pulmonary effects following prolonged or repeated inhalation of oil mist at airborne levels above the recommended mineral oil mist exposure limit. Symptoms of respiratory irritation may include coughing and difficulty breathing.
No specific first aid measures are required. As a precaution, remove clothing and shoes if contaminated. To remove the material from skin, use soap and water. Discard contaminated clothing and shoes or thoroughly clean before reuse.
Symptoms: High-Pressure Equipment Information: Accidental high-velocity injection under the skin of materials of this type may result in serious injury. The initial wound at the injection site may not appear to be serious at first; but, if left untreated, could result in disfigurement or amputation of the affected part. Contact with the skin is not expected to be harmful.
No specific first aid measures are required. As a precaution, remove contact lenses, if worn, and flush eyes with water.
Symptoms: Not expected to cause prolonged or significant eye irritation.
If swallowed, get immediate medical attention. Do not induce vomiting. Never give anything by mouth to an unconscious person.
Symptoms: Because of its low viscosity, this material can directly enter the lungs, if swallowed, or if subsequently vomited. Once in the lungs it is very difficult to remove and can cause severe injury or death.
Immediate Medical Attention
If swallowed, get immediate medical attention.
Medical Treatment
Note to Physicians: Ingestion of this product or subsequent vomiting may result in aspiration of light hydrocarbon liquid, which may cause pneumonitis.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use water fog, foam, dry chemical or carbon dioxide (CO2) to extinguish flames.
A complex mixture of airborne solids, liquids, and gases including carbon monoxide, carbon dioxide, and unidentified organic compounds will be evolved when this material undergoes combustion.
For fires involving this material, do not enter any enclosed or confined fire space without proper protective equipment, including self-contained breathing apparatus.
Firefighter Protection
Do not enter any enclosed or confined fire space without proper protective equipment, including self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Refer to Sections 5 and 8 for more information.
Stop the source of the release if you can do it without risk. Contain release to prevent further contamination of soil, surface water or groundwater.
Clean up spill as soon as possible, using appropriate techniques such as applying non-combustible absorbent materials or pumping.
Materials: non-combustible absorbent materials
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Do not get in eyes, on skin, or on clothing. Do not taste or swallow. Wash thoroughly after handling.
Not Applicable
Wash thoroughly after handling.
Do not pressurize, cut, weld, braze, solder, drill, grind, or expose such containers to heat, flame, sparks, static electricity, or other sources of ignition.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Use in a well-ventilated area.
Selection of chemical protective clothing should be performed by an Occupational Hygienist or Safety Professional and be based upon applicable standards (ASTM F739 or EN 374). Using chemical PPE depends upon operations conducted and may include chemical gloves. Refer to PPE manufacturers to obtain breakthrough time information to determine how long PPE can be used before it needs to be replaced. Chemical Glove Material: Butyl (0.7 mm, 15 minutes), Neoprene (0.61 mm, 120 minutes), Nitrile (0.8 mm, 120 minutes), Polyvinyl Chloride (PVC) (1.1 mm, 30 minutes), Viton Butyl (0.3 mm, 120 minutes).
Wear protective equipment to prevent eye contact. Selection of protective equipment may include safety glasses, chemical goggles, face shields, or a combination depending on the work operations conducted.
No respiratory protection is normally required. If user operations generate an oil mist, determine if airborne concentrations are below the occupational exposure limit for mineral oil mist. If not, wear an approved respirator that provides adequate protection from the measured concentrations of this material. For air-purifying respirators use a particulate cartridge.
Wear chemical personal protective equipment (PPE) to prevent skin contact. Selection of chemical protective clothing should be performed by an Occupational Hygienist or Safety Professional and be based upon applicable standards (ASTM F739 or EN 374). Using chemical PPE depends upon operations conducted and may include chemical gloves, boots, chemical apron, chemical suit, and complete facial protection.
See relevant Community environmental protection legislation or the Annex, as applicable.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
This material is considered stable under normal ambient and anticipated storage and handling conditions of temperature and pressure.
May react with strong acids or strong oxidizing agents, such as chlorates, nitrates, peroxides, etc.
Hazardous polymerization will not occur.
Not applicable
Not applicable
None known (None expected)
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
The material is not expected to be harmful to aquatic organisms based on the properties of its individual components.
12.2 Persistence and degradability
The material is not expected to be readily biodegradable based on the properties of its individual components.
12.3 Bioaccumulative potential
No data available for Bioconcentration Factor or Octanol/Water Partition Coefficient.
12.4 Mobility in soil
No data available.
12.5 Results of PBT and vPvB assessment
The product is not, or does not contain, a substance that is a potential PBT or a vPvB.
12.6 Endocrine Disrupting Properties
The mixture does not contain any substances that are assessed as having endocrine disrupting properties.
12.1 Toxicity
12.7 Other adverse effects
12.7 Other adverse effects
Based on available data, the classification criteria are not met
12.7 Other adverse effects
12.7 Other adverse effects
Not applicable
Bioaccumulative Potential:
12.7 Other adverse effects
Based on available data, the classification criteria are not met
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Use material for its intended purpose or recycle if possible. Oil collection services are available for used oil recycling or disposal.
Contact your sales representative or local environmental or health authorities for approved disposal or recycling methods.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
All components comply with the following chemical inventory requirements: AIIC (Australia), DSL (Canada), ENCS (Japan), IECSC (China), KECI (Korea), NZIoC (New Zealand), PICCS (Philippines), TCSI (Taiwan), TSCA (United States).
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Rando HD 10?
The signal word is danger.
What is the physical form of Rando HD 10?
Rando HD 10 is a liquid appearing as yellow with yellow color. It has hydrocarbon odor odor.
What is the solubility of Rando HD 10?
Soluble in hydrocarbons; insoluble in water
What is Rando HD 10 used for?
Hydraulic Oil
What are the hazard statements for Rando HD 10?
This substance has 1 hazard statement:
- H304: May be fatal if swallowed and enters airways
What is the melting point of Rando HD 10?
The melting point is No data available and the boiling point is 260°C (500°F) (Minimum).