NextSDS Logo
Safety Data Sheet EN

Rando HD 10

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Rando HD 10
Product Code
831448

Regulatory Identifiers

CAS Number
N/A
UFI Code
PF87-802E-900K-W8GW

Identified Uses

Hydraulic Oil

Manufacturers & Suppliers

Uno-X Smøreolje AS logo

Uno-X Smøreolje AS

national supplier

Gladengveien 2, NO-0661 Oslo, Norway

http://www.olje.unox.no

Emergency Contacts

CHEMTREC

+1 703 527 3887

Chevron Emergency Information Center

+1 510 231 0623

International calls accepted 24 hours

Poison Control Centre Norway

0047/22591300

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Asp. Tox. Cat. 1 H304

GHS Pictograms

GHS08 - Serious health hazard

GHS08

Hazard Statements

H304 May be fatal if swallowed and enters airways

Precautionary Statements

P301 + P310 IF SWALLOWED: Immediately call a POISON CENTER or doctor/physician
P331 Do NOT induce vomiting
P405 Store locked up
P501 Dispose of contents/container in accordance with applicable local/regional/national/international regulations

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

This material is a mixture.

Chemical Name CAS Number Concentration Hazardous
Distillates (petroleum), hydrotreated middle EC: 265-148-2 64742-46-7 70 - 99% Yes
2,6-di-tert-butylphenol EC: 204-884-0 128-39-2 0.25% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

No specific first aid measures are required. If exposed to excessive levels of material in the air, move the exposed person to fresh air. Get medical attention if coughing or respiratory discomfort occurs.

Symptoms: Not expected to be harmful if inhaled. Contains a petroleum-based mineral oil. May cause respiratory irritation or other pulmonary effects following prolonged or repeated inhalation of oil mist at airborne levels above the recommended mineral oil mist exposure limit. Symptoms of respiratory irritation may include coughing and difficulty breathing.

Skin contact

No specific first aid measures are required. As a precaution, remove clothing and shoes if contaminated. To remove the material from skin, use soap and water. Discard contaminated clothing and shoes or thoroughly clean before reuse.

Symptoms: High-Pressure Equipment Information: Accidental high-velocity injection under the skin of materials of this type may result in serious injury. The initial wound at the injection site may not appear to be serious at first; but, if left untreated, could result in disfigurement or amputation of the affected part. Contact with the skin is not expected to be harmful.

Eye contact

No specific first aid measures are required. As a precaution, remove contact lenses, if worn, and flush eyes with water.

Symptoms: Not expected to cause prolonged or significant eye irritation.

Ingestion

If swallowed, get immediate medical attention. Do not induce vomiting. Never give anything by mouth to an unconscious person.

Symptoms: Because of its low viscosity, this material can directly enter the lungs, if swallowed, or if subsequently vomited. Once in the lungs it is very difficult to remove and can cause severe injury or death.

Immediate Medical Attention

If swallowed, get immediate medical attention.

Medical Treatment

Note to Physicians: Ingestion of this product or subsequent vomiting may result in aspiration of light hydrocarbon liquid, which may cause pneumonitis.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use water fog, foam, dry chemical or carbon dioxide (CO2) to extinguish flames.

Specific hazards

A complex mixture of airborne solids, liquids, and gases including carbon monoxide, carbon dioxide, and unidentified organic compounds will be evolved when this material undergoes combustion.

Instructions

For fires involving this material, do not enter any enclosed or confined fire space without proper protective equipment, including self-contained breathing apparatus.

Firefighter Protection

Do not enter any enclosed or confined fire space without proper protective equipment, including self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Refer to Sections 5 and 8 for more information.

Environmental

Stop the source of the release if you can do it without risk. Contain release to prevent further contamination of soil, surface water or groundwater.

Cleanup methods

Clean up spill as soon as possible, using appropriate techniques such as applying non-combustible absorbent materials or pumping.

Materials: non-combustible absorbent materials

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Do not get in eyes, on skin, or on clothing. Do not taste or swallow. Wash thoroughly after handling.

Storage

Not Applicable

Hygiene

Wash thoroughly after handling.

Fire prevention

Do not pressurize, cut, weld, braze, solder, drill, grind, or expose such containers to heat, flame, sparks, static electricity, or other sources of ignition.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Use in a well-ventilated area.

Hands

Selection of chemical protective clothing should be performed by an Occupational Hygienist or Safety Professional and be based upon applicable standards (ASTM F739 or EN 374). Using chemical PPE depends upon operations conducted and may include chemical gloves. Refer to PPE manufacturers to obtain breakthrough time information to determine how long PPE can be used before it needs to be replaced. Chemical Glove Material: Butyl (0.7 mm, 15 minutes), Neoprene (0.61 mm, 120 minutes), Nitrile (0.8 mm, 120 minutes), Polyvinyl Chloride (PVC) (1.1 mm, 30 minutes), Viton Butyl (0.3 mm, 120 minutes).

Eyes

Wear protective equipment to prevent eye contact. Selection of protective equipment may include safety glasses, chemical goggles, face shields, or a combination depending on the work operations conducted.

Respiratory

No respiratory protection is normally required. If user operations generate an oil mist, determine if airborne concentrations are below the occupational exposure limit for mineral oil mist. If not, wear an approved respirator that provides adequate protection from the measured concentrations of this material. For air-purifying respirators use a particulate cartridge.

Skin/Body

Wear chemical personal protective equipment (PPE) to prevent skin contact. Selection of chemical protective clothing should be performed by an Occupational Hygienist or Safety Professional and be based upon applicable standards (ASTM F739 or EN 374). Using chemical PPE depends upon operations conducted and may include chemical gloves, boots, chemical apron, chemical suit, and complete facial protection.

Environmental

See relevant Community environmental protection legislation or the Annex, as applicable.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
Yellow
Colour
Yellow
Colour Intensity
---
Form
---
Odor
Hydrocarbon odor
Odor Threshold
No data available
Ph
Not Applicable
Melting Point
No data available
Boiling Point
260°C (500°F) (Minimum)
Flash Point
(Cleveland Open Cup) 125 °C (257 °F) (Minimum)
Freezing Point
No data available
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
No data available
Vapor Pressure
No data available
Vapor Density
No data available
Relative Density
---
Bulk Density
---
Density
0.8470 kg/l @ 15°C (59°F) (Typical)
Flammability
Not Applicable
Upper Explosive Limit
Not Applicable
Lower Explosive Limit
Not Applicable
Explosive Limits
---
Auto Ignition Temperature
No data available
Decomposition Temperature
No data available
Solubility
Soluble in hydrocarbons; insoluble in water
Partition Coefficient
No data available
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
9 mm2/s @ 40°C (104°F) (Minimum)
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

This material is considered stable under normal ambient and anticipated storage and handling conditions of temperature and pressure.

Reactivity

May react with strong acids or strong oxidizing agents, such as chlorates, nitrates, peroxides, etc.

Hazardous reactions

Hazardous polymerization will not occur.

Avoid

Not applicable

Incompatible

Not applicable

Decomposition

None known (None expected)

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Toxicity

This material is not expected to be harmful to aquatic organisms. The product has not been tested. The statement has been derived from the properties of the individual components.

The material is not expected to be harmful to aquatic organisms based on the properties of its individual components.

12.2 Persistence and degradability

This material is not expected to be readily biodegradable. The product has not been tested. The statement has been derived from the properties of the individual components.

The material is not expected to be readily biodegradable based on the properties of its individual components.

12.3 Bioaccumulative potential

Bioconcentration Factor: No Data Available Octanol/Water Partition Coefficient: No data available

No data available for Bioconcentration Factor or Octanol/Water Partition Coefficient.

12.4 Mobility in soil

No data available.

No data available.

12.5 Results of PBT and vPvB assessment

This product is not, or does not contain, a substance that is a potential PBT or a vPvB.

The product is not, or does not contain, a substance that is a potential PBT or a vPvB.

12.6 Endocrine Disrupting Properties

This mixture does not contain any substances that are assessed as having endocrine disrupting properties.

The mixture does not contain any substances that are assessed as having endocrine disrupting properties.

12.1 Toxicity

Component Information: Acute Toxicity: Distillates (petroleum), hydrotreated middle | Based on available data, the classification criteria are not met

12.7 Other adverse effects

No other adverse effects identified.

12.7 Other adverse effects

Distillates (petroleum), hydrotreated middle | Based on available data, the classification criteria are not met

Based on available data, the classification criteria are not met

12.7 Other adverse effects

Biodegradation: Distillates (petroleum), hydrotreated middle | Based on available data, the classification criteria are not met

12.7 Other adverse effects

2,6-di-tert-butylphenol | Not applicable

Not applicable

Bioaccumulative Potential:

Bioaccumulative Potential:

12.7 Other adverse effects

Distillates (petroleum), hydrotreated middle | Based on available data, the classification criteria are not met

Based on available data, the classification criteria are not met

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Use material for its intended purpose or recycle if possible. Oil collection services are available for used oil recycling or disposal.

Disposal

Contact your sales representative or local environmental or health authorities for approved disposal or recycling methods.

Waste Codes

13 01 10 EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

All components comply with the following chemical inventory requirements: AIIC (Australia), DSL (Canada), ENCS (Japan), IECSC (China), KECI (Korea), NZIoC (New Zealand), PICCS (Philippines), TCSI (Taiwan), TSCA (United States).

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Rando HD 10?

The signal word is danger.

What is the physical form of Rando HD 10?

Rando HD 10 is a liquid appearing as yellow with yellow color. It has hydrocarbon odor odor.

What is the solubility of Rando HD 10?

Soluble in hydrocarbons; insoluble in water

What is Rando HD 10 used for?

Hydraulic Oil

What are the hazard statements for Rando HD 10?

This substance has 1 hazard statement:

  • H304: May be fatal if swallowed and enters airways

What is the melting point of Rando HD 10?

The melting point is No data available and the boiling point is 260°C (500°F) (Minimum).