Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Rando HD 46
- Product Code
- 801658
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Hydraulic Oil
Uses advised against
Consult supplier when used other than those specified.
Manufacturers & Suppliers
Chevron Belgium BV
national supplier
Zuiderpoort Office Park, Gaston Crommenlaan 4, 9050 Gent, Belgium
0032/(0)9 293 71 11
Emergency Contacts
CHEMTREC
+1 703 527 3887
Centre Antipoisons
+32022649636
Chevron Emergency Information Center
+1 510 231 0623
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Distillates, hydrotreated heavy paraffinic EC: 265-157-1 | 64742-54-7 | 70 - 99% | No |
In accordance with the Regulation (EC) No 1272/2008, Nota L, reference IP 346/92: "DMSO Extraction Method", we have determined that the base oils used in this preparation contain <3% DMSO extract and are not carcinogenic.
First Aid Measures
Emergency procedures for chemical exposure incidents
If exposed to excessive levels of material in the air, move the exposed person to fresh air. Get medical attention if coughing or respiratory discomfort occurs.
Symptoms: No specific first aid measures are required.
As a precaution, remove clothing and shoes if contaminated. To remove the material from skin, use soap and water. Discard contaminated clothing and shoes or thoroughly clean before reuse.
Symptoms: No specific first aid measures are required.
As a precaution, remove contact lenses, if worn, and flush eyes with water.
Symptoms: No specific first aid measures are required.
Do not induce vomiting. As a precaution, get medical advice.
Symptoms: No specific first aid measures are required.
Immediate Medical Attention
Seek medical attention at once should an accident like this occur.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use water fog, foam, dry chemical or carbon dioxide (CO2) to extinguish flames.
A complex mixture of airborne solids, liquids, and gases including carbon monoxide, carbon dioxide, and unidentified organic compounds will be evolved when this material undergoes combustion.
For fires involving this material, do not enter any enclosed or confined fire space without proper protective equipment, including self-contained breathing apparatus.
Firefighter Protection
Do not enter any enclosed or confined fire space without proper protective equipment, including self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Observe all relevant local and international regulations. Keep out unnecessary and unprotected personnel. Persons entering the contaminated area to correct the problem or to determine whether it is safe to resume normal activities must comply with all instructions in the Exposure Controls/PersonalProtection section.
Stop the source of the release if you can do it without risk. Contain release to prevent further contamination of soil, surface water or groundwater.
Clean up spill as soon as possible, observing precautions in Exposure Controls/Personal Protection. Use appropriate techniques such as applying non-combustible absorbent materials or pumping.
Materials: non-combustible absorbent materials
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Do not get in eyes, on skin, or on clothing. Do not taste or swallow. Wash thoroughly after handling.
Not Applicable
Wash thoroughly after handling.
Electrostatic charge may accumulate and create a hazardous condition when handling this material. To minimize this hazard, bonding and grounding may be necessary but may not, by themselves, be sufficient. Review all operations which have the potential of generating and accumulating an electrostatic charge and/or a flammable atmosphere (including tank and container filling, splash filling, tank cleaning, sampling, gauging, switch loading, filtering, mixing, agitation, and vacuum truck operations) and use appropriate mitigating procedures.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Use in a well-ventilated area.
Refer to PPE manufacturers to obtain breakthrough time information to determine how long PPE can be used before it needs to be replaced. Unless specific glove manufacturer data indicates otherwise, the below table is based upon available industry data to assist in the glove selection process and is intended to be used as reference only. Butyl: 0.7 mm, 120 minutes; Nitrile: 0.8 mm, 240 minutes; Viton Butyl: 0.3 mm, 240 minutes.
Wear protective equipment to prevent eye contact. Selection of protective equipment may include safety glasses, chemical goggles, face shields, or a combination depending on the work operations conducted.
A site-specific risk assessment should be conducted by an Occupational Hygienist or a Safety Professional to determine the type and use of respiratory protective equipment. When a site-specific risk assessment determines that respiratory protection is required, use an approved respirator such as: Air purifying respirator - If airborne concentration limits exceed the applicable occupational exposure limit, but are below the maximum use concentration. Vapors only: organic vapor cartridge (filter type A3 per EN 529:2005). Vapors and particulates (including generated mists): both an organic vapor cartridge & particulate filter (AP3 filter per EN 529:2005). Refer to respirator manufacturers to obtain service life of cartridge / filter. Positive pressure air-supplying respirator - If airborne concentration limits exceed the maximum use concentration offered from an air purifying respirator. Refer to EN 529:2005, USA OSHA 1910.134, and/or other applicable local/regional/national/international standards for regulatory requirements.
Wear chemical personal protective equipment (PPE) to prevent skin contact. Selection of chemical protective clothing should be performed by an Occupational Hygienist or Safety Professional and be based upon applicable standards (ASTM F739 or EN 374). Using chemical PPE depends upon operations conducted and may include chemical gloves, boots, chemical apron, chemical suit, and complete facial protection.
See relevant Community environmental protection legislation or the Annex, as applicable.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
This material is considered stable under normal ambient and anticipated storage and handling conditions of temperature and pressure.
May react with strong acids or strong oxidizing agents, such as chlorates, nitrates, peroxides, etc.
Hazardous polymerization will not occur.
Not applicable
Not applicable
None known (None expected)
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
The material is not expected to be harmful to aquatic organisms based on the properties of the individual components.
12.2 Persistence and degradability
The material is not expected to be readily biodegradable based on the properties of its individual components.
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
The material does not meet the criteria for PBT or vPvB.
12.6 Endocrine Disrupting Properties
The mixture does not contain any substances that are assessed as having endocrine disrupting properties.
12.7 Other adverse effects
No other adverse effects identified.
12.7 Other adverse effects
Based on available data, the classification criteria are not met
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Use material for its intended purpose or recycle if possible. Oil collection services are available for used oil recycling or disposal.
Contact your sales representative or local environmental or health authorities for approved disposal or recycling methods.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
No components of this material were found on the regulatory lists searched (01-08).
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Rando HD 46?
The signal word is no signal word.
What is the physical form of Rando HD 46?
Rando HD 46 is a liquid appearing as brown to yellow with brown to yellow color. It has hydrocarbon odor odor.
What is the solubility of Rando HD 46?
Soluble in hydrocarbons; insoluble in water
What is Rando HD 46 used for?
Hydraulic Oil
What is the melting point of Rando HD 46?
The melting point is No data available and the boiling point is No data available.