Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Rando HD 10
- Product Code
- 273252, 274302
- Synonyms
- Rando HD 10 ISOCLEAN Certified
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Hydraulic Oil
Uses advised against
Consult supplier when used other than those specified.
Manufacturers & Suppliers
Chevron Canada Limited
manufacturer
500 - 5th Ave. SW, Calgary, ALBERTA T2P 0L7, Canada
(800) LUBE TEK
http://www.chevronlubricants.com
Emergency Contacts
CHEMTREC
(800) 424-9300
CHEMTREC
(703) 527-3887
Chevron Emergency Information Center
(800) 231-0623
Chevron Emergency Information Center
(510) 231-0623
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS08
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Highly refined mineral oil (C15 - C50) | --- | 80 - 100% | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
No specific first aid measures are required. If exposed to excessive levels of material in the air, move the exposed person to fresh air. Get medical attention if coughing or respiratory discomfort occurs.
Symptoms: Not expected to be harmful if inhaled. Contains a petroleum-based mineral oil. May cause respiratory irritation or other pulmonary effects following prolonged or repeated inhalation of oil mist at airborne levels above the recommended mineral oil mist exposure limit. Symptoms of respiratory irritation may include coughing and difficulty breathing.
No specific first aid measures are required. As a precaution, remove clothing and shoes if contaminated. To remove the material from skin, use soap and water. Discard contaminated clothing and shoes or thoroughly clean before reuse.
Symptoms: High-Pressure Equipment Information: Accidental high-velocity injection under the skin of materials of this type may result in serious injury. Seek medical attention at once should an accident like this occur. The initial wound at the injection site may not appear to be serious at first; but, if left untreated, could result in disfigurement or amputation of the affected part. Contact with the skin is not expected to cause prolonged or significant irritation. Contact with the skin is not expected to cause an allergic skin response. Not expected to be harmful to internal organs if absorbed through the skin.
No specific first aid measures are required. As a precaution, remove contact lenses, if worn, and flush eyes with water.
Symptoms: Not expected to cause prolonged or significant eye irritation.
If swallowed, get immediate medical attention. Do not induce vomiting. Never give anything by mouth to an unconscious person.
Symptoms: Highly toxic; may be fatal if swallowed. Because of its low viscosity, this material can directly enter the lungs, if swallowed, or if subsequently vomited. Once in the lungs it is very difficult to remove and can cause severe injury or death.
Immediate Medical Attention
If swallowed, get immediate medical attention. Seek medical attention at once should an accident like this occur. Immediate treatment at a surgical emergency center is recommended.
Medical Treatment
Ingestion of this product or subsequent vomiting may result in aspiration of light hydrocarbon liquid, which may cause pneumonitis. In an accident involving high-pressure equipment, this product may be injected under the skin. Such an accident may result in a small, sometimes bloodless, puncture wound. However, because of its driving force, material injected into a fingertip can be deposited into the palm of the hand. Within 24 hours, there is usually a great deal of swelling, discoloration, and intense throbbing pain. Immediate treatment at a surgical emergency center is recommended.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use water fog, foam, dry chemical or carbon dioxide (CO2) to extinguish flames.
No data available
Leaks/ruptures in high pressure system using materials of this type can create a fire hazard when in the vicinity of ignition sources (eg. open flame, pilot lights, sparks, or electric arcs).
This material will burn although it is not easily ignited. See Section 7 for proper handling and storage. For fires involving this material, do not enter any enclosed or confined fire space without proper protective equipment, including self-contained breathing apparatus.
Firefighter Protection
do not enter any enclosed or confined fire space without proper protective equipment, including self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Stop the source of the release if you can do it without risk.
Contain release to prevent further contamination of soil, surface water or groundwater.
Clean up spill as soon as possible, observing precautions in Exposure Controls/Personal Protection.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid contaminating soil or releasing this material into sewage and drainage systems and bodies of water. DO NOT USE IN HIGH PRESSURE SYSTEMS in the vicinity of flames, sparks and hot surfaces. Use only in well ventilated areas. Keep container closed. Do not taste or swallow. Wash thoroughly after handling.
Wash thoroughly after handling.
Do not use in the vicinity of flames, sparks and hot surfaces. Review all operations which have the potential of generating and accumulating an electrostatic charge and/or a flammable atmosphere.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Use in a well-ventilated area.
Chemical gloves. Butyl: 0.7 mm, 120 minutes; Nitrile: 0.8 mm, 240 minutes; Viton Butyl: 0.3 mm, 240 minutes. Refer to PPE manufacturers to obtain breakthrough time information to determine how long PPE can be used before it needs to be replaced.
Wear protective equipment to prevent eye contact. Selection of protective equipment may include safety glasses, chemical goggles, face shields, or a combination depending on the work operations conducted.
A site-specific risk assessment should be conducted by an Occupational Hygienist or a Safety Professional to determine the type and use of respiratory protective equipment. Air purifying respirator: Vapors only: organic vapor cartridge (filter type A3 per EN 529:2005). Vapors and particulates (including generated mists): both an organic vapor cartridge & particulate filter (AP3 filter per EN 529:2005). Positive pressure air-supplying respirator: If airborne concentration limits exceed the maximum use concentration offered from an air purifying respirator.
Wear chemical personal protective equipment (PPE) to prevent skin contact. Selection of chemical protective clothing should be performed by an Occupational Hygienist or Safety Professional and be based upon applicable standards (ASTM F739 or EN 374). Using chemical PPE depends upon operations conducted and may include chemical gloves, boots, chemical apron, chemical suit, and complete facial protection.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
This material is considered stable under normal ambient and anticipated storage and handling conditions of temperature and pressure.
May react with strong acids or strong oxidizing agents, such as chlorates, nitrates, peroxides, etc.
Hazardous polymerization will not occur. May react with strong acids or strong oxidizing agents, such as chlorates, nitrates, peroxides, etc.
Not applicable
None known (None expected)
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
ECOTOXICITY
PERSISTENCE AND DEGRADABILITY
POTENTIAL TO BIOACCUMULATE
MOBILITY
12.5 Results of PBT and vPvB assessment
12.6 Endocrine disrupting properties
12.7 Other adverse effects
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Oil collection services are available for used oil recycling or disposal.
Use material for its intended purpose or recycle if possible.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
All components comply with the following chemical inventory requirements: AIIC (Australia), DSL (Canada), EINECS (European Union), ENCS (Japan), IECSC (China), KECI (Korea), NZIoC (New Zealand), PICCS (Philippines), TCSI (Taiwan), TSCA (United States).
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is Rando HD 10 known by?
Rando HD 10 is also known as: Rando HD 10 ISOCLEAN Certified
What is the hazard signal word for Rando HD 10?
The signal word is danger.
What is the physical form of Rando HD 10?
Rando HD 10 is a liquid with yellow color. It has petroleum odor odor.
What is the solubility of Rando HD 10?
Soluble in hydrocarbons; insoluble in water
What is Rando HD 10 used for?
Hydraulic Oil
What are the hazard statements for Rando HD 10?
This substance has 1 hazard statement:
- H304: May be fatal if swallowed and enters airways
What is the melting point of Rando HD 10?
The melting point is Not Applicable and the boiling point is Not available.