Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Sika AnchorFix®-2 Part A
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
For further information, refer to product data sheet.
Manufacturers & Suppliers
Sika Corporation
manufacturer
201 Polito Avenue, Lyndhurst, NJ 07071, USA
(201) 933-8800
http://www.sikausa.com
Emergency Contacts
CHEMTREC
800-424-9300
Emergency Contact
+1-703-527-3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
GHS08
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Quartz (SiO2) >5μm | 14808-60-7 | 30 - 50% | Yes |
| Triethylene glycol dimethacrylate | 109-16-0 | 10 - 20% | Yes |
| aromatic amine ethoxylated | 103671-44-9 | 0.1 - 1% | Yes |
| benzyltrimethylammonium chloride | 56-93-9 | 0.1 - 1% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to fresh air. Consult a physician after significant exposure.
Take off contaminated clothing and shoes immediately. Wash off with soap and plenty of water. If symptoms persist, call a physician.
Remove contact lenses. Keep eye wide open while rinsing. If eye irritation persists, consult a specialist.
Clean mouth with water and drink afterwards plenty of water. Do not induce vomiting without medical advice. Do not give milk or alcoholic beverages. Never give anything by mouth to an unconscious person. Obtain medical attention.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.
Firefighter Protection
In the event of fire, wear self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Use personal protective equipment. Deny access to unprotected persons.
Do not flush into surface water or sanitary sewer system. If the product contaminates rivers and lakes or drains inform respective authorities. Local authorities should be advised if significant spillages cannot be contained.
Soak up with inert absorbent material
Materials: sand, silica gel, acid binder, universal binder, sawdust
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid exceeding the given occupational exposure limits (see section 8). Do not get in eyes, on skin, or on clothing. For personal protection see section 8. Persons with a history of skin sensitization problems or asthma, allergies, chronic or recurrent respiratory disease should not be employed in any process in which this mixture is being used.
Store in original container. Keep in a well-ventilated place. Observe label precautions. Store in accordance with local regulations.
Smoking, eating and drinking should be prohibited in the application area. Follow standard hygiene measures when handling chemical products.
Normal measures for preventive fire protection.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is chemically stable.
No dangerous reaction known under conditions of normal use.
Stable under recommended storage conditions.
No data available
No data available
No decomposition if stored and applied as directed.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
12.2 Persistence and degradability
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
12.6 Endocrine disrupting properties
12.7 Other adverse effects
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Disposal of this product, solutions and any by-products should at all times comply with the requirements of environmental protection and waste disposal legislation and any regional local authority requirements.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Sika AnchorFix®-2 Part A?
The signal word is danger.
What is the physical form of Sika AnchorFix®-2 Part A?
Sika AnchorFix®-2 Part A is a solid appearing as paste with gray color. It has aromatic odor.
What is Sika AnchorFix®-2 Part A used for?
For further information, refer to product data sheet.
What are the hazard statements for Sika AnchorFix®-2 Part A?
This substance has 4 hazard statements:
- H317: May cause an allergic skin reaction.
- H335: May cause respiratory irritation.
- H350: May cause cancer by inhalation.
- H372: Causes damage to organs (Lungs) through prolonged or repeated exposure.
What is the melting point of Sika AnchorFix®-2 Part A?
The melting point is No data available and the boiling point is 482 °F / 250 °C.