Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Dichloromethane for analysis EMSURE® ACS,ISO,Reag. Ph Eur
- Product Code
- 1.06050
- Chemical Name
- Dichloromethane
Regulatory Identifiers
- CAS Number
- 75-09-2 Check regulations →
- REACH No.
- 01-2119480404-41-XXXX
Identified Uses
Reagent for analysis
Manufacturers & Suppliers
Merck Life Science UK Limited
national supplier
New Road, The Old Brickyard, GILLINGHAM, Dorset, SP8 4XT, UNITED KINGDOM
+44 (0)1747 833-000
Emergency Contacts
CHEMTREC
+44 (0)870 8200418
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
GHS08
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Dichloromethane EC: 200-838-9 | 75-09-2 | 100% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
After inhalation: fresh air. Call in physician.
Take off immediately all contaminated clothing. Rinse skin with water/ shower. Consult a physician.
After eye contact: rinse out with plenty of water. Call in ophthalmologist. Remove contact lenses.
After swallowing: immediately make victim drink water (two glasses at most). Consult a physician.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.
For this substance/mixture no limitations of extinguishing agents are given.
Carbon oxides, Hydrogen chloride gas. Not combustible. Fire may cause evolution of: Hydrogen chloride gas, Phosgene. Ambient fire may liberate hazardous vapours.
Suppress (knock down) gases/vapours/mists with a water spray jet.
Firefighter Protection
Stay in danger area only with self-contained breathing apparatus. Prevent skin contact by keeping a safe distance or by wearing suitable protective clothing.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Do not breathe vapours, aerosols. Avoid substance contact. Ensure adequate ventilation. Evacuate the danger area, observe emergency procedures, consult an expert.
Do not let product enter drains.
Take up with liquid-absorbent material (e.g. Chemizorb®). Dispose of properly. Clean up affected area.
Materials: liquid-absorbent material (e.g. Chemizorb®)
Related Products
Similar products with comparable safety profiles
Chloroform for analysis EMSURE® ACS,ISO,Reag. Ph Eur
CAS: 67-66-3
Chloroform for analysis EMSURE® ACS,ISO,Reag. Ph Eur
CAS: 67-66-3
Trichloroethylene for analysis EMSURE® ACS,Reag. Ph Eur
CAS: 79-01-6
Methanol for analysis EMSURE® ACS,ISO,Reag. Ph Eur
CAS: 67-56-1
Trichloroacetic acid for analysis EMSURE® ACS,Reag, Ph Eur
CAS: 76-03-9
Trichloroacetic acid for analysis EMSURE® ACS, Reag. Ph Eur
CAS: 76-03-9
Ethyl acetate for analysis EMSURE® ACS,ISO,Reag. Ph Eur
CAS: 141-78-6
Ammonium chloride for analysis EMSURE® ACS,ISO,Reag. Ph Eur
CAS: 12125-02-9
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Work under hood. Do not inhale substance/mixture. Avoid generation of vapours/aerosols.
Protected from light. Tightly closed. Keep in a well-ventilated place. Keep locked up or in an area accessible only to qualified or authorised persons.
Immediately change contaminated clothing. Apply preventive skin protection. Wash hands and face after working with substance.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
This recommendation applies only to the product stated in the safety data sheet, supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN 16523-1 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de). - Splash contact - Material: Viton® - Minimum layer thickness: 0.7 mm - Break through time: 120 min - Material tested: Vitoject® (KCL 890 / Aldrich Z677698, Size M)
Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Safety glasses
Recommended Filter type: Filter AX (EN 371) The entrepreneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.
protective clothing
Do not let product enter drains.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is chemically stable under standard ambient conditions (room temperature). Contains the following stabiliser(s): 2-methyl-2-butene (0.002 %)
No data available
Risk of explosion with: Alkali metals, nitrogen oxides, nitrogen dioxide, Potassium, sodium azide, perchloric acid, Nitric acid, aluminium chloride, Amines, Oxygen (as liquefied gas), powdered aluminium, sodium, aromatic hydrocarbons, with powdered aluminium. Exothermic reaction with: Alkaline earth metals, Powdered metals, amides, alcoholates, nonmetallic oxides, potassium tert-butanolate, sodium amide, Lithium.
no information available
No data available
For Hazardous combustion products in the event of fire: see section 5
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
12.2 Persistence and degradability
12.3 Bioaccumulative potential
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
The substance/mixture contains no components considered to be either persistent, bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at levels of 0.1% or higher.
12.6 Endocrine disrupting properties
The substance/mixture does not contain components considered to have endocrine disrupting properties according to REACH Article 57(f) or Commission Delegated regulation (EU) 2017/2100 or Commission Regulation (EU) 2018/605 at levels of 0.1% or higher.
12.7 Other adverse effects
No data available
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Waste material must be disposed of in accordance with the national and local regulations. Leave chemicals in original containers. No mixing with other waste.
Leave chemicals in original containers. No mixing with other waste.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1593
- Shipping Name
- DICHLOROMETHANE
- Transport Class
- 6.1
- Packing Group
- III
Regulatory Information
Chemical regulations, safety assessments, and compliance status
This material safety data sheet complies with the requirements of Regulation (EC) No. 1907/2006.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Dichloromethane for analysis EMSURE® ACS,ISO,Reag. Ph Eur?
The signal word is warning.
What is the physical form of Dichloromethane for analysis EMSURE® ACS,ISO,Reag. Ph Eur?
Dichloromethane for analysis EMSURE® ACS,ISO,Reag. Ph Eur is a liquid with colourless color. It has ether-like odor.
What is Dichloromethane for analysis EMSURE® ACS,ISO,Reag. Ph Eur used for?
Reagent for analysis
What are the hazard statements for Dichloromethane for analysis EMSURE® ACS,ISO,Reag. Ph Eur?
This substance has 4 hazard statements:
- H315: Causes skin irritation.
- H319: Causes serious eye irritation.
- H336: May cause drowsiness or dizziness.
- H351: Suspected of causing cancer.
What is the melting point of Dichloromethane for analysis EMSURE® ACS,ISO,Reag. Ph Eur?
The melting point is Melting point/ range: -95 °C at 1,013 hPa and the boiling point is 40 °C at 1,013 hPa.