Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- MANGALOX SLURRY
- Product Form
- Mixture
- Product Code
- AS 4570
- Synonyms
- Manganese ore
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
For use in: Ceramics, Glass.
Uses advised against
This product must not be used in applications other than those identified above, without first seeking advice of the supplier
Manufacturers & Suppliers
SCR-Sibelco NV
manufacturer
Plantin en Moretuslei 1A, 2018 Antwerpen - Belgium
Sibelco Winterswijk
manufacturer
Steengroeveweg 50, 7101 PH Winterswijk - The Netherlands
+31 (0)543 561461
Emergency Contacts
Sibelco
+31 43 3663755
during office hours
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Braunite, brown EC: 305-405-9 | 94551-57-2 | 60% | No |
| Water EC: 231-791-2 | 7732-18-5 | 25 - 35% | No |
| Hausmannite EC: 215-266-5 | 1317-35-7 | 3% | Yes |
| Quartz (fine fraction) EC: 238-878-4 | 14808-60-7 | 1% | Yes |
Notes
E: Exempted from REACH registration
First Aid Measures
Emergency procedures for chemical exposure incidents
Move the affected person away from the contaminated area and into the fresh air.
Wash skin with plenty of water and soap.
Rinse with copious quantities of water and seek medical attention if irritation persists.
Rinse mouth. Get medical advice/attention.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
No specific extinguishing media is needed.
No restriction on the extinguishing media to be used.
Fire hazard : Not combustible.
Firefighter Protection
No specific fire-fighting protection is required.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Do not breathe aerosol. If spilled, may cause the floor to be slippery.
No special requirements.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Prevent aerosol formation or splashes. Handle packaged products carefully to prevent accidental bursting. If you require advice on safe handling techniques, please contact your supplier. Ensure operatives are trained to minimise exposures.
Keep containers closed and store packaged products so as to prevent accidental bursting.
Do not eat, drink and smoke in work areas; wash hands after use; remove contaminated clothing and protective equipment before entering eating areas.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Minimise airborne dust generation. Use process enclosures, local exhaust ventilation or other engineering controls to keep airborne levels below specified exposure limits. If user operations generate dust, fumes or mist, use ventilation to keep exposure to airborne particles below the exposure limit. Apply organisational measures, e.g. by isolating personnel from dusty areas. Provide a good standard of controlled ventilation (5 to 10 air changes per hour). Local exhaust ventilation - efficiency of at least: 90%.
Appropriate protection (e.g. gloves, barrier cream) is recommended for workers who suffer from dermatitis or sensitive skin. Wash hands at the end of each work session.
Wear safety glasses with side-shields in circumstances where there is a risk of penetrative eye injuries.
The use of half or full face masks with filters against particles of category 2 or 3 (FP2 - FP3) is recommended. See EN 143: 2021 - Respiratory protective devices. Particle filters. Efficiency of at least: 90%
Appropriate protection (e.g. gloves, barrier cream) is recommended for workers who suffer from dermatitis or sensitive skin. Wash hands at the end of each work session.
Avoid wind dispersal.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Chemically stable.
Inert, not reactive.
No hazardous reactions.
Not relevant.
No particular incompatibility.
Not relevant.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1. Toxicity
12.2. Persistence and degradability
12.3. Bioaccumulative potential
12.3. Bioaccumulative potential
Partition coefficient n-octanol/water (Log Pow) is not applicable. Bioaccumulative potential is considered not relevant, although some organisms accumulate Si(OH)4.
12.4. Mobility in soil
12.5. Results of PBT and vPvB assessment
Not relevant
12.6. Endocrine disrupting properties
12.7. Other adverse effects
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Where possible recycling is preferred to disposal.
Recycling and disposal of packaging should be carried out by an authorised waste management company.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Works involving exposure to respirable crystalline silica dust generated by a work process are included in Directive (EU) 2017/2398 of 12 December 2017 amending Directive 2004/37/EC on the Protection of Workers from the risks related to exposure to Carcinogens or Mutagens at work.
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is MANGALOX SLURRY known by?
MANGALOX SLURRY is also known as: Manganese ore
What is the hazard signal word for MANGALOX SLURRY?
The signal word is no signal word.
What is the physical form of MANGALOX SLURRY?
MANGALOX SLURRY is a liquid appearing as slurry with black color. It has odourless odor.
What is the solubility of MANGALOX SLURRY?
Water: Negligible
What is MANGALOX SLURRY used for?
For use in: Ceramics, Glass.
What is the melting point of MANGALOX SLURRY?
The melting point is 0 °C and the boiling point is 100 °C.