NextSDS Logo
Safety Data Sheet EN

MAXIMUM STRENGTH PAINTSTRIPPER

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
MAXIMUM STRENGTH PAINTSTRIPPER

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Product for surface preparation of buildings surfaces. Use in accordance with directions on the product label.

Manufacturers & Suppliers

ICI Paints AkzoNobel logo

ICI Paints AkzoNobel

manufacturer

Wexham Road, Slough, Berkshire, SL2 5DS, U.K.

+44 (0) 333 222 71 71

http://www.polycell.co.uk

Emergency Contacts

Emergency Contact

+44 (0)344 892 0111

Emergency Contact

+44 (0) 1753 550000

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Flam. Liq. Cat. 3 H226

GHS Pictograms

GHS02 - Flammable

GHS02

Hazard Statements

H226 Flammable liquid and vapour.

Precautionary Statements

P101 If medical advice is needed, have product container or label at hand.
P102 Keep out of reach of children.
P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P403 + P235 Store in a well-ventilated place. Keep cool.
P501 Dispose of contents and container in accordance with all local, regional, national or international regulations.

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
n-butyl acetate EC: 204-658-1 123-86-4 15 - 20% Yes
cyclohexanone EC: 203-631-1 108-94-1 10% Yes
2-aminoethanol EC: 205-483-3 141-43-5 0.3% Yes

There are no additional ingredients present which, within the current knowledge of the supplier and in the concentrations applicable, are classified as hazardous to health or the environment, are PBTs, vPvBs or Substances of equivalent concern, or have been assigned a workplace exposure limit and hence require reporting in this section.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove victim to fresh air and keep at rest in a position comfortable for breathing.

Symptoms: Headache, dizziness, fatigue, muscular weakness, drowsiness and, in extreme cases, loss of consciousness. Mucous membrane and respiratory system irritation.

Skin contact

Flush contaminated skin with plenty of water. Remove contaminated clothing and shoes. Get medical attention if symptoms occur.

Symptoms: Removal of natural fat from the skin, resulting in non-allergic contact dermatitis and absorption through the skin.

Eye contact

Immediately flush eyes with plenty of water, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Get medical attention if irritation occurs.

Symptoms: Irritation and reversible damage.

Ingestion

Wash out mouth with water. If material has been swallowed and the exposed person is conscious, give small quantities of water to drink. Do not induce vomiting unless directed to do so by medical personnel.

Symptoms: Nausea, diarrhea and vomiting.

Immediate Medical Attention

Contact poison treatment specialist immediately if large quantities have been ingested or inhaled.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use dry chemical, CO₂, water spray (fog) or foam.

Unsuitable media

Do not use water jet.

Specific hazards

Flammable liquid and vapour. Runoff to sewer may create fire or explosion hazard. In a fire or if heated, a pressure increase will occur and the container may burst, with the risk of a subsequent explosion.

Instructions

Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training. Move containers from fire area if this can be done without risk. Use water spray to keep fire-exposed containers cool.

Firefighter Protection

Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode. Clothing for fire-fighters (including helmets, protective boots and gloves) conforming to European standard EN 469 will provide a basic level of protection for chemical incidents.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

No action shall be taken involving any personal risk or without suitable training. Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilt material. Shut off all ignition sources. No flares, smoking or flames in hazard area. Put on appropriate personal protective equipment.

Small spill

Stop leak if without risk. Move containers from spill area. Use spark-proof tools and explosion-proof equipment. Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material and place in an appropriate waste disposal container. Dispose of via a licensed waste disposal contractor.

Large spill

Stop leak if without risk. Move containers from spill area. Use spark-proof tools and explosion-proof equipment. Approach the release from upwind. Prevent entry into sewers, water courses, basements or confined areas. Wash spillages into an effluent treatment plant or proceed as follows. Contain and collect spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations. Dispose of via a licensed waste disposal contractor. Contaminated absorbent material may pose the same hazard as the spilt product.

Environmental

Avoid dispersal of spilt material and runoff and contact with soil, waterways, drains and sewers.

Cleanup methods

Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material. Wash spillages into an effluent treatment plant or proceed as follows. Contain and collect spillage.

Materials: non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Put on appropriate personal protective equipment (see Section 8). Do not ingest. Avoid contact with eyes, skin and clothing. Avoid breathing vapour or mist. Use only with adequate ventilation. Wear appropriate respirator when ventilation is inadequate. Do not enter storage areas and confined spaces unless adequately ventilated. Keep in the original container or an approved alternative made from a compatible material, kept tightly closed when not in use. Store and use away from heat, sparks, open flame or any other ignition source. Use explosion-proof electrical (ventilating, lighting and material handling) equipment. Use only non-sparking tools. Take precautionary measures against electrostatic discharges. Empty containers retain product residue and can be hazardous. Do not reuse container.

Storage

Store in original container protected from direct sunlight in a dry, cool and well-ventilated area, away from incompatible materials (see Section 10) and food and drink.

Hygiene

Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Remove contaminated clothing and protective equipment before entering eating areas.

Fire prevention

Store and use away from heat, sparks, open flame or any other ignition source. Use only non-sparking tools. Take precautionary measures against electrostatic discharges.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Use only with adequate ventilation. Use process enclosures, local exhaust ventilation or other engineering controls to keep worker exposure to airborne contaminants below any recommended or statutory limits. The engineering controls also need to keep gas, vapour or dust concentrations below any lower explosive limits. Use explosion-proof ventilation equipment.

Hands

Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary. Considering the parameters specified by the glove manufacturer, check during use that the gloves are still retaining their protective properties. It should be noted that the time to breakthrough for any glove material may be different for different glove manufacturers. In the case of mixtures, consisting of several substances, the protection time of the gloves cannot be accurately estimated. When prolonged or frequently repeated contact may occur, a glove with a protection class of 6 (breakthrough time >480 minutes according to EN374) is recommended. Recommended gloves: Viton ® or Nitrile, thickness ≥ 0.38 mm. When only brief contact is expected, a glove with protection class of 2 or higher (breakthrough time >30 minutes according to EN374) is recommended. Recommended gloves: Nitrile, thickness ≥ 0.12 mm. Gloves should be replaced regularly and if there is any sign of damage to the glove material. The performance or effectiveness of the glove may be reduced by physical/chemical damage and poor maintenance. The user must check that the final choice of type of glove selected for handling this product is the most appropriate and takes into account the particular conditions of use, as included in the user's risk assessment.

Eyes

Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists, gases or dusts. If contact is possible, the following protection should be worn, unless the assessment indicates a higher degree of protection: safety glasses with side-shields.

Respiratory

Based on the hazard and potential for exposure, select a respirator that meets the appropriate standard or certification. Respirators must be used according to a respiratory protection program to ensure proper fitting, training, and other important aspects of use.

Skin/Body

Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. When there is a risk of ignition from static electricity, wear anti-static protective clothing. For the greatest protection from static discharges, clothing should include anti-static overalls, boots and gloves. Refer to European Standard EN 1149 for further information on material and design requirements and test methods. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.

Environmental

Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
Liquid.
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
Various: See label.
Colour Intensity
---
Form
---
Odor
Not available.
Odor Threshold
Not available.
Ph
7 [Conc. (% w/w): 100%] [DIN EN 1262]
Melting Point
Not available.
Boiling Point
126°C (258.8°F)
Flash Point
Closed cup: 23°C (73.4°F) [Pensky-Martens]
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
water: 23.8 mm Hg (3.2 kPa); n-butyl acetate: 11.25 mm Hg (1.5 kPa) [DIN EN 13016-2]; cyclohexanone: 3.75 mm Hg (0.5 kPa); dimethyl sulfoxide: 0.42 mm Hg (0.056 kPa) [EU A.4]; 2-aminoethanol: 0.4 mm Hg (0.053 kPa)
Vapor Density
Not available.
Relative Density
1.411
Bulk Density
---
Density
1.411 g/cm³ [DIN EN ISO 2811-1]
Flammability
---
Upper Explosive Limit
---
Lower Explosive Limit
---
Explosive Limits
---
Auto Ignition Temperature
Isotridecanol, ethoxylated: 250°C (482°F) [ASTM E 659-78]; dimethyl sulfoxide: 300 to 302°C (572 to 575.6°F); 2-aminoethanol: 410°C (770°F); n-butyl acetate: 415°C (779°F) [EU A.15]; cyclohexanone: 420°C (788°F)
Decomposition Temperature
---
Solubility
---
Partition Coefficient
Not applicable.
Solubility In Water
Soluble [OESO (TG 105)]
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
2834 mm²/s [DIN EN ISO 3219]
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is stable.

Reactivity

No specific test data related to reactivity available for this product or its ingredients.

Hazardous reactions

Under normal conditions of storage and use, hazardous reactions will not occur.

Avoid

Avoid all possible sources of ignition (spark or flame). Do not pressurise, cut, weld, braze, solder, drill, grind or expose containers to heat or sources of ignition.

Incompatible

Reactive or incompatible with the following materials: oxidising materials

Decomposition

Under normal conditions of storage and use, hazardous decomposition products should not be produced.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Toxicity

There are no data available on the mixture itself. Do not allow to enter drains or watercourses. The mixture has been assessed following the summation method of the CLP Regulation (EC) No 1272/2008 and is not classified as hazardous to the environment, but contains substance(s) hazardous to the environment. See section 3 for details. | Product/ingredient name | Result | Species | Exposure | | --- | --- | --- | --- |

The mixture is not classified as hazardous to the environment based on the summation method, though it contains hazardous substances.

12.1 Toxicity

| Product/ingredient name | Result | Species | Exposure | | n-butyl acetate | Acute LC50 32 mg/l Marine water | Crustaceans - Artemia salina | 48 hours | | | Acute LC50 62000 μg/l Fresh water | Fish - Danio rerio | 96 hours | | | Acute LC50 100000 μg/l Fresh water | Fish - Lepomis macrochirus | 96 hours | | | Acute LC50 185000 μg/l Marine water | Fish - Menidia beryllina | 96 hours | | | Acute LC50 18000 μg/l Fresh water | Fish - Pimephales promelas | 96 hours |

12.1 Toxicity

| Product/ingredient name | Result | Species | Exposure | | cyclohexanone | Acute EC50 32.9 mg/l | Algae - Chlamydomonas reinhardtii - Exponential growth phase | 72 hours | | | Chronic EC10 3.56 mg/l | Algae - Chlamydomonas | 72 hours |

12.1 Toxicity

Product/ingredient name | Result | Species | Exposure | 2-aminoethanol | Acute EC50 8.42 mg/l Fresh water Acute LC50 >100000 μg/l Marine water Acute LC50 170 mg/l Fresh water | reinhardtii - Exponential growth phase Algae - Desmodesmus subspicatus Crustaceans - Crangon crangon - Adult Fish - Carassius auratus | 72 hours 48 hours 96 hours

12.1 Toxicity

Conclusion/Summary : Not available.

Not available.

12.2 Persistence and degradability

Conclusion/Summary : Not available.

Not available.

12.3 Bioaccumulative potential

Product/ingredient name | LogPow | BCF | Potential

12.3 Bioaccumulative potential

| Product/ingredient name | LogPow | BCF | Potential | | n-butyl acetate | 2.3 | - | low |

12.3 Bioaccumulative potential

| Product/ingredient name | LogPow | BCF | Potential | | cyclohexanone | 0.86 | - | low |

12.3 Bioaccumulative potential

| Product/ingredient name | LogPow | BCF | Potential | | 2-aminoethanol | -1.31 | - | low |

12.4 Mobility in soil

Soil/water partition : Not available. coefficient (Koc) Mobility : Not available.

Data not available.

12.5 Results of PBT and vPvB assessment

This mixture does not contain any substances that are assessed to be a PBT or a vPvB.

The mixture does not contain any substances that are assessed to be a PBT or a vPvB.

12.6 Endocrine disrupting properties

Not available.

12.7 Other adverse effects

No known significant effects or critical hazards.

No known significant effects or critical hazards.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

The generation of waste should be avoided or minimised wherever possible. Disposal of this product, solutions and any by-products should at all times comply with the requirements of environmental protection and waste disposal legislation and any regional local authority requirements. Dispose of surplus and non-recyclable products via a licensed waste disposal contractor. Waste should not be disposed of untreated to the sewer unless fully compliant with the requirements of all authorities with jurisdiction.

Disposal

Dispose of surplus and non-recyclable products via a licensed waste disposal contractor.

Waste Codes

08 01 99 wastes not otherwise specified EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
UN1263
Shipping Name
PAINT RELATED MATERIAL
Transport Class
3
Packing Group
III
ADR

Transport within user's premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.

IMDG

Transport within user's premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

UK (GB) /REACH

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for MAXIMUM STRENGTH PAINTSTRIPPER?

The signal word is warning.

What is the physical form of MAXIMUM STRENGTH PAINTSTRIPPER?

MAXIMUM STRENGTH PAINTSTRIPPER is a liquid. with various: see label. color. It has not available. odor.

What is MAXIMUM STRENGTH PAINTSTRIPPER used for?

Product for surface preparation of buildings surfaces. Use in accordance with directions on the product label.

What are the hazard statements for MAXIMUM STRENGTH PAINTSTRIPPER?

This substance has 1 hazard statement:

  • H226: Flammable liquid and vapour.

What is the melting point of MAXIMUM STRENGTH PAINTSTRIPPER?

The melting point is Not available. and the boiling point is 126°C (258.8°F).