Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
PhenolNeutrAll®
Product Code
EST 00950

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Medical Device for skin decontamination

Manufacturers & Suppliers

E

ESTbiochem GmbH

manufacturer

Luchsweg 22, D-50259 Pulheim

+49 2238 92999-59

Emergency Contacts

Giftzentrale München

49/(0)89 19240

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Polyethylene Glycol 400 EC: 500-038-2 25322-68-3 92% No
Water EC: 231-791-2 7732-18-5 6% No
Sodium decanoat EC: 213-688-4 1002-62-6 1.5% No
Sodium laurethsulfat EC: 221-416-0 15826-16-1 0.5% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove victim to fresh air and keep at rest in a position comfortable for breathing. Get medical advice/attention if you feel unwell.

Skin contact

Remove/Take off immediately all contaminated clothing. Rinse skin with water/shower. If skin irritation or rash occurs: Get medical advice/attention.

Eye contact

Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. If eye irritation persists: Get medical advice/attention.

Ingestion

Get medical advice/attention if you feel unwell. Rinse mouth.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Dry chemical, foam, water spray, carbon dioxide.

Unsuitable media

Solid streams of water

Specific hazards

Carbon monoxide, carbon dioxide etc

Instructions

Fire-extinguishing work is done from the windward and the suitable fire-extinguishing method according to the surrounding situation is used. In case of fire in the surroundings: Remove movable containers if safe to do so.

Firefighter Protection

When extinguishing fire, be sure to wear personal protective equipment

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Use personal protective equipment. Keep people away from and upwind of spill/leak. Ensure adequate ventilation. Entry to non-involved personnel should be controlled around the leakage area by roping off, etc

Large spill

In case of large amount of spillage, contain a spill by bunding.

Environmental

Prevent product from entering drains

Cleanup methods

Absorb spilled material in a suitable absorbent

Materials: rag, dry sand, earth, saw-dust

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Wear suitable protective equipment. Prevent generation of vapour or mist. Wash hands and face thoroughly after handling. Avoid contact with skin, eyes and clothing.

Storage

Keep container tightly closed. Store in a cool and dark place.

Hygiene

Wash hands and face thoroughly after handling.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Install a closed system or local exhaust as possible so that workers should not be exposed directly.

Hands

Protective gloves.

Eyes

Safety glasses. A face-shield, if the situation requires.

Respiratory

Vapor respirator. Follow local and national regulations.

Skin/Body

Protective clothing. Protective boots, if the situation requires.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
Colorless - Almost colorless
Colour Intensity
---
Form
Viscous clear
Odor
Slightly charact.
Odor Threshold
---
Ph
8,0 - 8,5
Melting Point
---
Boiling Point
---
Flash Point
224°C
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
0.012Pa/100°C
Vapor Density
---
Relative Density
1.13
Bulk Density
---
Density
---
Flammability
---
Upper Explosive Limit
---
Lower Explosive Limit
---
Explosive Limits
---
Auto Ignition Temperature
305°C
Decomposition Temperature
---
Solubility
---
Partition Coefficient
---
Solubility In Water
Very soluble
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under proper conditions.

Reactivity

No data available

Hazardous reactions

No special reactivity has been reported.

Avoid

No data available

Incompatible

Oxidizing agents

Decomposition

Carbon monoxide, carbon dioxide etc

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Toxicity

- Fish: No data available - Crustacea: No data available - Algae: No data available

No data available for fish, crustacea, or algae.

12.2 Persistence and degradability

No data available

12.3 Bioaccumulative potential

No data available

12.4 Mobility in soil

Log Pow: No data available Soil adsorption (Koc): No data available Henry's Law (PaM³/mol): No data available

No data available for Log Pow, Soil adsorption (Koc), or Henry's Law.

12.5 Results of PBT and vPvB assessment

- PBT: Not applicable - vPvB: Not applicable

The substance is not classified as PBT or vPvB.

12.6 Other adverse effects

No data available
13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Burn in a chemical incinerator equipped with an afterburner and scrubber system.

Disposal

Consult your local regional authorities. Observe all federal, state and local regulations when disposing of the substance.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for PhenolNeutrAll®?

The signal word is no signal word.

What is the physical form of PhenolNeutrAll®?

PhenolNeutrAll® is a liquid with colorless - almost colorless color. It has slightly charact. odor.

What is PhenolNeutrAll® used for?

Medical Device for skin decontamination