Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- LAPIDON ENTKALKERLIQUID
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Deliming agent bonding agent for lime
Manufacturers & Suppliers
DFS-Diamon GmbH
manufacturer
Ländenstrasse 1, 93339 Riedenburg
09442 9189 0
Emergency Contacts
Emergency Contact
09442 9189 0
Giftnotruf München
+49-(0)89-19240
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS05
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Preparation of: complexing agent, Inorganic Acids, Organic acids, anionic surfactants
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Phosphonic acid, modified EC: 220-552-8 | 2809-21-4 | --- | Yes |
For the wording of the listed risk phrases refer to section 16.
First Aid Measures
Emergency procedures for chemical exposure incidents
Supply fresh air; consult doctor in case of complaints.
Immediately wash with water and soap and rinse thoroughly.
Rinse opened eye for several minutes under running water. Then consult a doctor.
Seek medical treatment. Rinse out mouth and then drink plenty of water. Do not induce vomiting. Never give anything by mouth to an unconscious person.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
CO2, powder or water spray. Fight larger fires with water spray or alcohol resistant foam.
Water with full jet
In case of fire, the following can be released: Carbon monoxide (CO) + Carbon dioxide (CO2) Phosphorus oxides (e.g. P2O5). Under certain fire conditions, traces of other toxic gases cannot be excluded.
Firefighter Protection
Wear self-contained respiratory protective device.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Keep people at a distance and stay on the windward side. Refer to protective measures listed in sections 7 and 8.
Do not allow to enter sewers/ surface or ground water. Do not allow to penetrate the ground/soil.
Absorb with liquid-binding material
Materials: sand, diatomite, acid binders, universal binders, sawdust
Related Products
Similar products with comparable safety profiles
POLYESTERLIQUIDE
---
TAXAT LIQUID
UFI: ASMG-6T5P-4W0Y-CGAX
Liquidum Desinfectans 90 % v/v Desinfectant 90 % v/v
---
CLEANING LIQUID, (ESL5)
---
TEROSON AL 7163 LIQUID APPLIED
---
PROLAN PROTECTIVE LANOLIN – GLEITMITTEL
---
Liquidum Desinfectans 70 % v/v Desinfectant 70 % v/v
---
LITHOPONE 30 %
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Keep receptacles tightly sealed.
Protect from frost. Keep container tightly sealed.
No special measures required.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Protective gloves. Material of gloves: Nitrile rubber, NBR. Recommended thickness of the material: ≥ 0.4 mm. Penetration time of glove material Value for the permeation: Level ≤ 6 (480 min). As protection from splashes gloves made of the following materials are suitable: Butyl rubber, BR, Nitrile rubber, NBR
Tightly sealed goggles
Use suitable respiratory protective device only when aerosol or mist is formed.
Acid resistant protective clothing
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No decomposition if used according to specifications.
No further relevant information available.
Corrosive action on metals. Reacts with alkali (lyes).
No further relevant information available.
amines, strong alkalies, strong oxidising agents
None, if handled according to order.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.6 Other adverse effects
12.1 Toxicity
12.2 Persistence and degradability
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
After prior treatment product has to be disposed of in an incinerator for hazardous waste adhering to the regulations pertaining to the disposal of particularly hazardous waste.
Must not be disposed together with household garbage.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 3265
- Shipping Name
- CORROSIVE LIQUID, ACIDIC, ORGANIC, N.O.S. (Phosphonic acid, modified)
- Transport Class
- 8
- Packing Group
- III
Warning: Corrosive substances.
Warning: Corrosive substances.
Warning: Corrosive substances.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The product is classified and labelled according to the CLP regulation.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for LAPIDON ENTKALKERLIQUID?
The signal word is danger.
What is the physical form of LAPIDON ENTKALKERLIQUID?
LAPIDON ENTKALKERLIQUID is a fluid with milky white color. It has pungent odor.
What is LAPIDON ENTKALKERLIQUID used for?
Deliming agent bonding agent for lime
What are the hazard statements for LAPIDON ENTKALKERLIQUID?
This substance has 1 hazard statement:
- H318: Causes serious eye damage.
What is the melting point of LAPIDON ENTKALKERLIQUID?
The melting point is Not determined and the boiling point is 100 °C.